Fume Hood Cabinet
Get Price Quote
Zexter Fume Hood
74,500 Per Nos
1 Nos (MOQ)
Product Overview: Our chemical fume hoods are conceptualized and designed to provide a work area which is free from all the potentially hazardous fumes or chemical effluents that may be emitted during the course of a given experiment or procedure in a laboratory. Our fume hoods capture the fumes released during an experiment by drawing fresh air from the environment, past the user into the unit.. This way the concentration of the chemical fumes/effluents are kept at the minimum possible levels in and around the breathing zone of the user. The vector of the air in the fume hood points to the inward direction and perpendicular to the face of the user. The velocity of the air is controlled at approximately 80 feet per minute, so as to control the particle kinetics of various aerosols and diffused gases. Features: Ergonomic Design Energy Efficient Mechanism Low Noise Levels Conforms To ASHRAE-110-1995 (British Standard) Testing Method. Construction Details: Our fume hoods are developed to be used as semi closed ventilated enclosures so as to protect the user from harmful and toxic fumes and vapors and to eliminate the possibility of accidental fire, which may be resulted due to the emission of inflammable gases during the course of a given experiment. Hence the material of construction of all our fume hoods are carefully chosen S.S-316 grade/ M.S duly Powder Coated. The work table is made of heavy gauges SS-316. Our entire fume hoods are provided with sliding sash made out of special grade shatter proof temper glass duly framed in aluminum frame with sliding motion and counter weight balanced mechanism. Our units ensure minimum illumination level of approx 800 lux on the work table. The unit is equipped very diligent heavy duty exhaust system, comprising of dynamically balanced centrifugal impeller with high speed motor of approx 1440 RPM (Heavy Duty 1/4 H.P A.C Motor/ 1/2 H.P A.C Motor/ 1 H.P A.C Motor/ 1.5 H.P A.C Motor ).
Best Deals from Fume Hood
Fume Hood
Get Price Quote
Fume Hood (Model No.RS00C0102) Specification:- Product over View: ⢠Our fume hoods are conceptualized and designed to provide a work area which is free from all the potentially hazardous fumes or chemical effluents that may be emitted during the course of a given experiment or procedure in a laboratory. ⢠Our fume hoods capture the fumes released during an experiment by drawing fresh air from the environment, past the user into the unit. ⢠This way the concentration of the chemical fumes/effluents are kept at the minimum possible levels in and around the breathing zone of the user. ⢠The vector of the air in the fume hood points to the inward direction and perpendicular to the face of the user. ⢠The velocity of the air is controlled at approximately 80 feet per minute, so as to control the particle kinetics of various aerosols and diffused gases . 03 Nos. of valves, one is for Water/Liquid, Another one is for Gas/Air, and last one for Vacuum. )3 Nos. of Multi Power Socket 15 amp. (make Northwest) Features: ï¶ Ergonomic Design ï¶ Energy Efficient Mechanism ï¶ Low Noise Levels ï¶ Conforms To ASHRAE-110-1995 (British Standard) Testing Method.
Chemical Fume Hood
85,000 Per Piece
1 Piece (MOQ)
fabricated thick mild steel/stainless steel duly powder coated painted. Working table top is fitted with black granite and three side wall fitted with highlem sheet (acid proof) a small wash basin with connections provided for inlet and outlet of water. The front door moves vertically up and down with concealed counter balanced weight. The unit if fitted with fluorescent light and a gas and water tap supply. The space under the work station can be provided with storage compartments for storage purpose. The front facing panel is fitted with 15/5 amp socket with switches for exhaust system and fluorescent light. To work on 220/230 volts a. C. Supply.
Fume Hood
85,000 - 250,000 Per Piece
1 Piece (MOQ)
Chemical Fume Hood
Get Price Quote
Laboratory Fume Hood Stations by Bionics Scientific are available in various sizes and dimensions to meet specific requirements of your research. These fume hoods have a choice of vertical or horizontal sliding sash and MS or stainless steel construction. The standard sizes of our fume hoods are available in most demanded requirements (4ft, 5 ft, 6 ft & 8 ft). Often known as chemical fume hood, these systems also dilute effect on flammable gases and vapors. Our product range includes general purpose fume hoods, ductless fume hoods, and mobile units; designed with number of optional features and specifications required to meet critical challenges in laboratory research areas worldwide.
Polypropylene Fume Hood
Get Price Quote
Polypropylene Fume Hood for high acid and trace metal analysis use. WEIBER offers a range of Pp Fume Hood constructed from all white stress-relieved, acid resistant, non-corrosive polypropylene. These hoods are specially engineered for use with harsh corrosive acids. They are available as conventional total exhaust hoods providing only operator protection, and as HEPA-filtered laminar flow fume hoods providing both operator and product protection. Constructed almost entirely of polypropylene, this fume hood contains the Zero Leak Airflow System, available only from. The system prevents uneven particulate loading by eliminating direct blasts to the HEPA filter, dispensing air over 100% of the surface. These cabinets meet Federal Standard 209e, Class 10 air quality conditions, and have been independently tested for containment properties in accordance to ASHRAE Standard 110-1995 for Fume Hoods. Microprocessor based controls Manufactured from all-white, structural polypropylene. Conventional total exhaust hoods are suitable for applications with harsh corrosive acids which regular steel hoods may not withstand. A microprocessor controller monitors face velocity and displays the real-time airflow on the LCD screen in linear feet per minute. Have an advanced airfoil design that is important to the overall safety and performance of the fume hood. A removable work surface exposes a spill basin that may be fitted with a drain for disposal of any spills. Built-in vapor-proof fluorescent light Easy-access utilities panel for operation and maintenance Flame-retardant polypropylene interior - higher temperature working range than fiberglass. HEPA-filtered laminar flow fume hoods are suitable for use with trace metal applications. These units incorporate a top located filtration system powered by a dynamically balanced motorized impeller for even air distribution and excellent energy efficiency resulting in quiet operation. Available with a wide range of options and accessories, including, service fixtures, sinks, electrical outlets, digital airflow alarms and base cabinetry. Corrosion resistant interiors and exteriors.
Fume Hoods
Get Price Quote
FRP Fume Hood
Get Price Quote
Fume Hood
Get Price Quote
We manufacture Fume Hood that is available in different shapes and sizes. The Fume Hood, available with us, is aptly designed to release all the toxic vapors and hence protecting the instruments as well as people working in the lab. Salient Features : Robust constructionHigh capacityDimensional accuracyEasy to useCost effective Ideal for : Laboratories Specifications : Working Size :4' x 2' x 2'6' x 2' x 2'5' x3' x 2'
Fume Hood
117,000 Per Piece
Fume Hood
Get Price Quote
Fume Hood
Get Price Quote
Incubators, Kjeldahl Distillation Assembly, Seed Germinator
Fume Hood
Get Price Quote
Industrial Furnaces, Rapid Moisture Tester, Gold Melting Furnace
Fume Hood
Get Price Quote
Autoclave, Autopsy Table, Bio Safety Cabinet, Fermentor Vessel