Ozone Environment Chamber
Ozone Environment Chamber Xgen150 is a computerized environmental exposure chamber providing continuous Ozone measurement, control, recording and reporting of the entire exposure sequence.The control system is integrated with an Ultra-Violet (U.V.) absorption based, high precision, In-situ Ozone measurement system The Xgen150 ® provides the ability to be hybridized for both Ultra-Violet lamp and Corona Discharge based Ozone generation. The Xgen150 ® is also equipped to provide operators the ability to test material under both Revolution Static and Dynamic tensile strain while enclosed inside in the exposure environment.
...moreOscillating Disc Rheometer
Brief Description The Future Foundation Oscillating Disc Rheometer is a shearing disk (rotor) rheometer, designed for accurate measurement of the rheological properties of elastomeric compounds. The instrument consists of a rotor (Biconical disc) embedded in the test piece between a sealed die cavity, which is made to oscillate through a small specified rotary amplitude. This action exerts a shear strain on the test piece and the torque (force) required to oscillate the disc depends upon stiffness (shear modulus) of the rubber compound. The entire test sequence is controlled via our operations software RheoLab ®. The Rheometer not only exhibits the curing characteristics of the Rubber Compound but it also monitors the processing characteristics as well as the physical properties of the material. The “Cure Curve” (Rheograph) obtained with a Rheometer is a finger print of the compound’s vulcanization and processing character. Applications • Processing Behavior Characterization • New Research and Product Development • Inline Production quality control • Effects of new ingredients • Optimization of ingredient dose • Production throughput & Cost reduction Features and Benefits Complies with ASTM D02084, ISO 3417 Easy Automated Software controlled Test sequence • Torque Parameters: MI,ML,MH/MHR, Optimum Cure • Cure Time Parameters: ts1,ts2,ts5, tc10,tc30,tc50,tc90 • Derived Parameters: Thermoplasticity, CureRate, Reversion time Trend: Temperature: • Direct Die mounted Heaters • Microprocessor Controlled with PT-100 RTD • Calibrated Range: 50°C to 200°C • Accuracy: ± 0.5 °C Measurement transducer : • Direct inline reaction torque transducer • Four Arm temperature compensated strain gage Sophisticated Software Based Recording and Real-time Display : • High-Speed RS-232 connected Computer controlled test sequence • Real-time display during run-testing • Automatic computation of results. • In-Build Comprehensive Statistical Analysis Package • Multiple Curve, Quality Gates graphical testing • Statistical Analysis of Results • Control Chart of Critical Test Parameters • Statistical Quality Control Reporting
Speed : 1.67Hz/ 100cpm
...moreMoving Die Rheometer
The Xgen100® is equipped with an On-Board 24Bit Microprocessor (MPU) providing both Stand-alone (without PC) and with PC operability. The high precision of the 24Bit MPU provides In-Situ measurement of Elastic S', Viscous S'' Modulus and Tan delta (δ) process parameters. Touch-Pad Control Panel with backlit Digital read-out displays critical test parameters (Temperature, Time, and Torque) and can be connected to a Dot-Matrix Printer for cost-efficient reporting. The MDR Xgen100 has been benchmarked to provide repeatability to all global branded Rotorless Rheometers.
Speed : 1.67Hz/ 100cpm
...moreMooney Viscometer
It is an instrument consisting of a motor driven disk within a die cavity formed by two dies maintained at specified conditions of temperature and die closure force. It measures the effect of temperature and time on viscosity of rubber or compound.It is a measure of the viscosity of a rubber or compound determined in a Mooney shearing disk viscometer. It is indicated by the torque required to rotate the disk embedded in a rubbercompound specimen and enclosed in the die cavity under specified conditions.Deviation in viscosity of the compound will critically alter its processibility specially in terms of calendering, extruding or injection moulding. It is necessary that viscosity parameter be maintained within specified limits. To do this Mooney Viscometer is of vital importance. In fact viscometer has manifold advantages.
Temperature : 50 to 200oC