Ultrasound System
Technical Specifications : Imaging Technologies: High-precision digital continuous beam former Dynamic frequency fusion imaging High-precision delayed point-to-point dynamic receiving and focusing Superwide frequency imaging Adaptive image optimization Adaptive vascular imaging Adaptive Doppler imaging THI Applicable for the whole body, including but not limited to abdomen, Gyn., Obs., Cardiology, Vasuclar, Urology, Small organs, Mammary gland, paediatrics and neonatus, fetal cardiac imaging, puncture. Power :19.5V, 11.8A DC input Display : 17 / 19 / 21 inches medical grade monitor Probe Ports : 3 activated probe ports supporting convex, linear, phased array, endocavitary probes. Integrative network ultrasonic workstation. Available for DICOM. Scanning modes :B, M, CFM, PDI, PW, THI Image processing technologies Acoustic beam processing: full digital multi-beam former, real-time point-to-point dynamic receiving and focusing, continuous dynamic focusing, real-time dynamic variable aperture imaging, real-time dynamic acoustic beam apodization, dynamic filtering, dynamic frequency scanning. Image pretreatment Overall gain: 0~100 adjustable TGC:8 TGC sliders Gain control:B+M adjustable, CFM adjustable, PDI adjustable, PW adjustable Acoustic output: Low, middle, high adjustable Grey levels: grade 0 to 15 adjustable Digital channels: 32 High-precision digital continuous beam former Edge enhancement 5 grades adjustable Frame average 6 grades adjustable Line average 3 grades adjustable Gamma correction grade 0 to 30 adjustable Contrast: 0~100 Brightness: -50~+50 Scanning parameters B mode Acoustical power: Low, middle, high adjustable B gains: 0-100 Danymic range: 120dB M mode M acoustical power: Low, middle, high adjustable B gains: 0-100 M scanning speed: Low, middle, high adjustable M sampling line visible & adjustable CFM color Doppler mode CFM gain: 0-100 CFM wall filtering: 4 steps CFM baseline adjustment: 9 steps CFM frame average: 4 steps Maximum PRF:14kHz Minimum PRF:0.5kHz CDE Power Doppler mode CDE gain: 0-100 PD frame average: 4 steps PD wall filtering: 4 steps Maximum PRF:14kHz Minimum PRF:0.5kHz PW Spectral Doppler mode PW gain:0-100 PW dynamic range: 4 steps PW wall filtering: 4 steps PW color Digital wall filtering: 4 steps PW scanning speed: 4 steps (120,180,240,300) Sampling volume width: 1-15mm Angle correction Baseline adjustment: 9 steps Maximum PRF(speed):15kHz Minimum PRF(speed):1kHz Maximum detectable speed:21m/s(7.18m/s) Minimum detectable speed:0.05cm/s Image display 256 gray scale Grey histogram display Image rotation : left / right, up / down, 90oC Depth : 3 to 24 cm (22 grades) depending on probes Emit focus : maximum 8 focus points (depending on probe types and depth) Dynamic range : ≥120dB (visible & adjustable) Real-time zoom : 6 times zoon in, zoom rate adjustable M mode speed : 3 grades adjustable Angle change : 3 angles (available for convex probe) Display TGC curve Video output : auto-select NTSC or PAL video format Screen display information Header information area: hospital log, hospital name, system date and time, patient information, TI/MI value, probe model and current mode. Menu adjustment area: image adjustment and optimization; pseudo colors, rotation and reverse; dynamic range, frame average, linear average, linear density, acoustic power of image real-time scanning; remark texts of current mode; body mark of current mode;basic measurement and applicable measurement items of current model under frozen condition. Parameter and measurement area: parameters of current image scanning; related measurement and calculation results when measuring. Image area: to display images under each mode and measurements and each texts, arrows. Caliper area: to display depth reference caliper, grey grade caliper, CFM or power's speed caliper; TGC curve displays or hides automatically according to parameter setup. Record area: to display current image and status messages being saved in video buffer in live condition; to display the saved total frames and status message of current frame under frozon condition. Menu status area: to display the status of related parameters in both live and frozon conditions. Acoustic output information: TI, MI, acoustic power(PH2、PL2 、PM2)。 Measurement / Calculation B mode normal measurements: distance, circumrence (Ellipse & method of loci), area (Ellipse & method of loci), volume (Ellipse, method of loci and two-planes models), ratio and angle. M mode normal measurements: distance, time, slope and heart rate. PW mode normal measurements: time, heart rate, velocity, acceleration, resistance index. CFM、PDI mode normal measurements:distance, circumrence (Ellipse & method of loci), area (Ellipse & method of loci), volume (Ellipse, method of loci and two-planes models), ratio and angle. Gynecological measurement: uterus (uterus, cervix and endometria), ovarian volume and left & right follicle. Obstetric measurement: EDD table :GS, BPD, CRL, FL, YS, TAD, LV, OFD, NT, AC, HC, APAD, Cxlength。 Cardialogy measurement: applicable measurements for aortic, aortic vaivem, left atrium, LV, mitral vaive, right atrium, right ventricle, circulatory system. Urological measurment: prostate volume, seminal vesicle size, transition zone volume, bladder volume, testicular volume, residual urine volume, renal volume. Superficial organs measurement: thyroid gland. Others: calculations of hip angles by drawing baselines, ridge line and apical line. Measurement Reports Obs., Gyn., Cardiac, Urological and other measurement reports Measurement results saved automatically and generates reports Marks ≥95 body marks Text marks Arrow marks Storage Image storage, video storage, cine loop(≥300 frames), disk storage≥160G. Peripheral Devices Recorder, USB removable storage device Digital, video printers Laser, jet printers S-Video、AV video output Puncture guide line Puncture guide functions available for all probes. Angle of puncture guide line is adjustable and predefined. Winning Advantages : Powerful software packages on Gyn. Obs, small organ, cardiac, abodomen, uorology, MSK, vessels, fetal etc. Image Quality is better and can be compared with renowned Global Brands. 17 / 19 / 21 inches LCD monitor, Fashionable design, In-built battery Triplex / Duplex, 3D / 4D optional, Advanced signals processing technology Excellent measurement and calculation programs for General, Obstetrics, Gynecology, Urology, Small Parts, Cardiac, Skeletal & Muscles Vascular examinations especially on vessels, Blood " Ultrasound Scanner Machines will be Sold & Purchased strictly as per the applicable Guidelines of PC & PNDT."
...moreTransport Monitor
Technical Specifications: Power Supply : AC100~240V, 50/60HZ,Adapter: Output 9VDC, 5A Battery: 2500mAh 7.4V Rechargeable battery. Rated Charging Current:1250mA. Charge Cycle : 300 times Working time: 2hours ECG: Lead Mode: 3/5 Leads, I, II, III orI, II, III, AVR, AVL, AVF, V. Gain: ´2.5, 5.0mm/mV, 10mm/mV, 20mm/mV Heart Rate : Measure Range : Adult : 15 ~ 300 bpm; Neonatal/Pediatric : 15~350bpm, Accuracy : ± 1% Resolution :1 bpm; Differential Input Impedance> 5 M ohm CMRR : Diagnostic Mode>90 dB; Monitor Mode >105 dB; Surgery Mode >105 dB; Leakage Current< 10 μA PACE Pulse Detects: Range : ±2~±700mV ; Width : 0.1~2ms ; Rise Time : 10~100µs Bandwidth: Surgery:1 ~ 20 Hz; Monitor : 0.5 ~ 35 Hz; Diagnostic : 0.05 ~ 130 Hz ST Measurement : Range : -2.0 ~ +2.0 mV ; Accuracy : -0.8mV~+0.8mV: ±0.02mV or ±10%, which is greater Other Range: unspecified Respiration: Method Impedance between RA-LL, RA-LA; Differential Input Impedance>2.5 M ohm; Respiration Impedance Range: 0.3~3Ω; Base Impedance Range : 200Ω-4000Ω; Bandwidth 0.3 ~ 2.5 Hz Gain *0.25, *0.50, *1, *2, Respiration Rate : Adult : 0 ~ 120 BrPM; Neonatal /Pediatric:0 ~ 150 BrPM; Resolution:1 BrPM; Accuracy:±2 BrPM or ±2%, use the greater. Apnea Alarm:10 ~ 40 s NIBP: Method Oscillometric; Measure Mode : Manual, Auto, STAT; Measure Interval in AUTO Mode 1~99 min; Measure and Alarm Range : 0mmHg(0kPa)~300mmHg(40.0kPa); Static Pressure Accuracy : ±3mmHg Resolution : 1mmHg; Accuracy : Maximum Mean error : ±5mmHg; Maximum Standard Deviation : 8mmHg Overpressure Protection : Adult : 300 mmHg;Pediatric : 240mmHg;Neonatal : 150 mmHg SpO2: Measurement Range : 0 ~ 100 % ; Resolution : 1 %; Accuracy: 70% ~ 100% ±2 % 40% ~ 69% ±3 % 0% ~ 39% unspecified Pulse Rate : Measure and Alarm Range : 20~300bpm; Resolution : 1bpm; Accuracy : ±3bpm Temperature: Measure and Alarm Range : 0 ~ 50 °C; Resolution : 0.1°C CO2(optional): MeasureRange : 0% ~ 13%; Resolution : 1 mmHg; Breath Rate : 0 - 150 bpm Recorder(optional): Paper Width : 50mm; Speed : 12.5/25/50 mm/s; WaveChannel : 3channels Dimension & Weight: 210 × 130 ×75mm; About 1Kg
...moreSyringe Pump
Technical Specifications : Injection Rate : 50(60)ml Syringe: 0.1 - 999.9 ml/h (0.1ml/h step) 1000 - 1500ml/h (1ml/h step) 30ml Syringe: 0.1 - 900 ml/h (0.1ml/h step) 20ml Syringe: 0.1 - 600 ml/h (0.1ml/h step) 10ml Syringe: 0.1 - 300 ml/h (0.1ml/h step) 5ml syringe: 0.1 - 100ml/h (0.1ml/h step) Rate Accuracy : Within ±3% (after correct calibration) Mechanical Accuracy : Within ±2% Purge Rate : 50(60)ml Syringe: 1500ml/h 30ml Syringe: 900ml/h 20ml Syringe: 600ml/h 10ml Syringe: 300ml/h 5ml Syringe: 100ml/h Bolus Rate : 50(60)ml Syringe: 1200ml/h 30ml Syringe: 720ml/h 20ml Syringe: 480ml/h 10ml Syringe: 240ml/h 5ml Syringe: 100ml/h Occlusion : High: 800mmHg±200mmHg Medium: 500mmHg±100mmHg Low: 300mmHg±100mmHg Volume Limit / Total Injection : 0.1 - 999.9ml (0.1ml step) KVO Speed : 0.1 ~ 5ml/h (0.1ml/h step). KVO Rate : 1ml/h Power Source : 100-240VAC, 50/60Hz. Power Consumption : 30VA. Dimension : 280(L)x210(W)x130mm(H). Net Weight : 2.2Kg. Winning Advantages: HD LCD Dynamic Displays working status. High Capacity Words. User Friendly Interface. Alarm : Audible / Visual for Occlusion, Empty, Near Empty, Low Battery, End of Injection, Syringe Loose, Wrong Settings. Preset Solution Volume greatly reduces nurses workload. Working Modes : Rate mode, Time Volume mode, Dosage Weight mode. Freely Stackable upto a maximum of 8 to provide multiple solutions for wide range of clinical applications. One - key Operation makes setup easy and simple. Automatically records the settings of last injection. Syringe plunger grabble detector, operable with one hand in a No - Germ Environment. DC12V car charge. Internal Rechargeable Li Battery ≥1, 600mAh 4 hours backup. KJ-810D stores 2000 Injection records. Drug Library Available.
...moreSlit Lamps
Winning Advantages: Converging Optics Design. Three Magnifications (10X, 16X & 25X) with Different Eyepieces. Main Mirrors Use Imported Material. Mirrors tested for Moisture, Mould and Coating Processing, hence Good Optic Performance in all Weather Conditions. German Industrial Bulb, High - Lightness without Harsh, Quick Heat Dispersion. One Piece Preset Lens and One Diffuse Lens for Free International Standard Accessory Interface which Connect Kinds of Laser Adapter and Goldman Tonometer.
...moreSlit Lamp Microscope
Winning Advantages: Classic Galilean Type Microscope Total Magnification Ratio : ivSM 26 : 6X, 10X, 16X, 25X, 40X | ivSM 26S : 10X, 16X, 25X Max Aperture Diameter : 14mm Convergence Angle of Eyepieces : 13° Excellent stability, available with applanation, digital camera, CCD, teaching tube, etc. Powed by low color temperature LED lamp*Light of LED lamp is very similar to traditional halogen lamp, which conforms to doctor's examination habit.
...moreSiemens MRI Machine
Brand Name : Siemens
Model Number : Magnetom Concerto
Magnetic Strength : 0.2 Tesla (T)
Application : Hospital,Diagnostic Centre
...moreRefurbished MRI Machine
Application : Hospital,Diagnostic Centre
Rebound Tonometer
Winning Advantages: A handset device Probe has very less contact with patient, avoiding discomfort reaction. Automatic exist function of probe.
...moreoxygen concentrators
Technical Specifications : Oxygen Density 93%±3% V/V Running Noise ≤48dB(A) Max. flow 3L/min Power consumption ≤320(W) Net Wt. 20kg Dimension 395x310x610 (LxWxH)mm Continuous Working Time 10000hours Winning Advantages: Adopts american PSA technology, use Physical method to separate pure oxygen from air. America imported molecule sieve, long life and more efficiency. New fashion design, beautiful appearance. Advanced oil-free compressor, save 10% power energy. 24 hours continuous working available. Big LCD Screen easy to operate. Optional remote control with timing setting. Power off alarm, abnormal voltage alarm. Time keeping and time counting. Optional nebulizer and oxygen purity alarm function. Basic function: Time counting, Power off alarm and abnormal voltage alarm, Timing & Remote control.
...moreoptical coherence tomography machine
Winning Advantages: High Performance at a low price: Modular design increases flexibility, Reusability and Maintainability. Personalized design according to the customer's needs cab be provided. With the powerful software, it has clear, easy to use interface and support multiple language. Anterior Segment Analysis Template : Anterior segment with optional modules, able to observe and analyzer the anterior segment.
...moreOpthalmic Scan machine
Technical Specifications : A Scan Probe 10MHz import small size probe, built-in luminotron Measuring Range 15 - 40mm Measurement Precision ±0. 05mm; with macula lutea trace function Measurement Anterior chamber depth, lens thickness, vitreous body length, total length and average Method of Measurement immersion and contact Eye mode Phakic / Aphakic / Dense / various IOL IOL formula SRK-II, SRK-T, BINKHORST- II, HOLLADAY, HOFFER Storage 10 cases, 5 readings each case Output A scan waveform and IOL calculation sheet Winning Advantages: Large color liquid-crystal screen Touch screen input, easy operation Curve freezing : Manual / Auto mode, controlled by pedal Built-in Speed Thermal Printer Enter the Name & ID; easy to check archive
...moreOphthalmoscope
Winning Advantages: Elegant appearances. Convenient for mobile inspection. Both common dry cell and rechargeable battery power are applicable.
...moreOphthalmic Lens Meter
200,000 Per Piece
Weight : 5.0 Kg
Operation Microscope
Winning Advantages: Electromagnetic lock and balance technology ensure the easy operation and stable orientation. Cold light source is bright and even enough, which does no harm to tissues. Germany imported Schott optics and apochromatic technology ensure clear field of view and high resolutions. Aspheric and BIOM added on objective could meet the demands of vireo-retinal operations. Applications : Ophthalmic Operations, Neurosurgical, ENT, Cardio-Thoracic Surgical Operations, etc. Optional Accessories : Oblique illumination, Fundus Aspheric Lens and Inversion (BIOM)Lens.
...moreBreast Cancer Diagnostic Apparatus
1,000,000 Per Piece
1 Piece (MOQ)
Color : White
Led Head Lamp
10,000 Per Piece
1 Piece (MOQ)
Lighting Type : LED
Power : 5W
Country of Origin : Made in India
...moreInfusion Pump
30,000 Per Piece
Fundus Camera
Winning Advantages: Non-mydriatic fundus camera Adopts the Fifth Generation leading Optical System Auto Focus, Auto Exposure mode & Manual Focus, Manual Exposure mode Professional HD SLR camera, up to 24.1 mega pixels. Five internal fixation, two dots alignment Dicom 3.0 interface (optional)
...moreFinger Pulse Oximeters
Technical Specifications : Display: HD LED Screen Accuracy: Sp02: 70%-100%,±2% Pulse Rate: 30-99bpm,±2bpm;100-250bpm,±2bpm Battery: AAAx2 Dimensions: 62.0x37.OX32.0mm Weight(without batteries):28.7g Parameters: Pulse Rate, SpO2 Indication: Low battery Application Range: Adult, Adolescent, Child Winning Advantages: High Accuracy. Real-time measurement Indication. Good assistant for doctors and nurses. Focus on your Sp02. Take care of your health. HD large screen. Unique soft silicon housing provide clear and comfortable measurement. With a vastly improved LED and sensor, it allows Sp02 (Blood Oxygen Saturation level) and pulse rate measurement even at low blood perfusion. With ALARM function will remind patients to notice SpO2 and PR value change. It can be used in monitoring oxygen therapy effect. SUITABLE FOR ALL AGES - Finger chamber with SMART Spring System. Accommodates wide range of finger sizes- children to adult.
...moreFetal Monitor
Technical Specifications: Display : 12.1 inch LED (0-90 degree rotation) Resolution : 1024*768 pixels Power supply and battery : 100 - 240 VAC, 50 / 60Hz; Input Power: 70 to 100 VA Battery : Rechargeable lithium battery : 14.8 V / 2200 mAh; Charge Cycle : more than 500 times Working time : 2 hours (optional larger battery for 4-5 hours) Recorder (Built-in) : Thermal printer; Paper : Z-fold, thermo sensitive; Paper width: 112mm or 150mm; Print speed : 1/2/3 cm/min ; Trace : Max. 4 tracks ; Recording way : Real-time Recording ; Review printing Alarm : Level : Low, Medium and High ; Indication : Auditory, Visual, delay of FHR alarm Input Device : Knob, Keypad Input. Optional : Touch screen; Mouse / keyboard input Trend & Reviewing : Cardiotocography (CTG) : Waveform review : 8640h; Vital signs: Trend graph and table : 2160h ; Waveform Review: 2h; Alarm Review : 2000 groups Dimension and weight : 360 * 310 * 120mm; 5.3KG (excluding accessories) NST Report (Option) Based on Fischer evaluation method (monitoring time ≥ 20 min) Automatic Score result : Score 8 - 10 excellent Score 5 - 7 suspicious Score 0 - 4 foetus hypoxia
...moreFetal Doppler
Technical Specifications : High Sensibility. Monitor >12 weeks unborn baby's pulse rate. LCD Display : 44.5x23mm. 3 Calculation Mode to calculate Fetal Heart Rate : Instant, 10 s, Average and Manual. Ultrasonic emitting frequency: 3MHz + 10%, Continuous wave Doppler, Output power: 7.9mW. Overall sensitivity at the distances 200mm from the face of the probe (Doppler frequency: 500±50Hz, Target velocity: 10cm/s~40cm/s): 92.4dB. Spatial-peak temporal-peak acoustic pressure: 20.1kPa. Effective area of the ultrasonic transducer active element: 3.07cm2 Acoustic coupling medium for normal use: ph: 5.5~8, Acoustic impedance: ≤1.7*105g /cm2s. Power : 2x1.5V AA rechargable battery. Stand by Time: > _hours. Auto Shut off : 60 s. Consumption :
...moreesu machine
Functions: Uses high current to ionize argon gas and release the energy to cut and coagulate the body tissues. Winning Advantages: Optimize the coagulation effect during the large diffuse hemorrhage. Two auto switched argon gas bottles. Monopolar / Bipolar Auto switch Function. Two pressure decrease valves, Section control argon gas to 0.1L/min. with higher accuracy. Multiple-points monitor the argon gas input and output quantity and pressure to ensure the safety. ENDOCUT, Pure cut, Coagulation can be separately operated, operation power can be automatically adjusted and combined. Argon gas flow quantity of cut and coagulation can be separately controlled. Simulated the ENDOCUT mode to avoid perforating the tissues ,misusing, and the burns to the patient. Fixed Coagulation depth (0.5 - 3.00mm) , avoid perforating the tissues, no carbide, no smoke. Power compensation system (PPS) , Automatic control cutting effect, make the cutting effect in consistent. Wider Impedance Recognition (50-1800Ω), meets all kinds of environments, without frequent power adjustment match all kinds of surgeries. Split type Less bleeding, no oxidation and eschar advantages than traditional electrosurgical units. Applications: Therapy surgery of Gynecology, E.N.T, Surgery under the celoscope and bonchoscope, bipolar electrosurgical cut surgery of prostate and uterus cavity.
...moreElectric Suction Apparatus
Technical Specifications :
ECG Machine
Salient Features: 3 channel ECG machine with interpretation 5.0" color TFT LCD display Simultaneous 12 leads acquisition and 1, 1+1, 3 channel (Manual/Auto) recording with high resolution thermal printer Manual/Auto working modes Use digital isolation technology and digital signal processing Baseline stabilization inspection Full alphanumeric silicon keyboard Support U disk and SD card storage Support WIFI connection workstation (optional)
...moreBe first to Rate