Model 670 Fume Hood Monitor
12,500 Per Piece
model 670 fume hood monitor ensures proper fume hood performance the model 670 fume hood monitor continuously senses air flow through the face of the fume hood, ensuring safe levels of fresh air are exhausting. The 670 provides a highly accurate hot wire sensor to detect very low flows common on fume hoods. The model 670 comes with everything required to quickly install the unit including a mounting bracket, 24" of tubing for connecting to the inside of the hood wall and a 120 volt ac power adapter. product applications fume hood ventilation monitoring modeldescription 670fume hood monitor. specifications service:fume hood face velocity air flow. alarm range:30-400 fpm (0.15-2.0 m/s). alarm indication:red led & audible alarm. low air velocity alarm delay:fixed 5 secs. visual led display:red: alarm; green: normal. horn silence:yes, temporary and permanent. accuracy:face velocity ±10%. temperature limits:operating temperature: 55 to 86°f (13 to 30°c). Storage temperature: -40 to 150°f (-40 to 65°c). power requirement:15 vdc 500 ma; 120 vac, 60 hz power transformer included. relay output low air flow alarm:5 a @ 250 vac. relay input for night setback:2 wire rated for 24 vdc usage. sash high indication:using a two wire micro switch or 3 wire proximity switch input, rated for 24 vdc usage. mounting:semi flush, flush or surface mounted when using included bracket. weight:5.0 oz (141 g). agency approval:ce. features flexible surface or flush mounting led safe and alarm status indicators audible alarm sash alarm input night set-back input related products model 480 vaneometer™ swing vane anemometer model 480 vaneometer™ swing vane anemometer series 641 air velocity transmitter series 641 air velocity transmitter series adps/edps differential pressure switch series adps/edps differential pressure switch
Zexter Fume Hood
74,500 Per Nos
1 Nos (MOQ)
Product Overview: Our chemical fume hoods are conceptualized and designed to provide a work area which is free from all the potentially hazardous fumes or chemical effluents that may be emitted during the course of a given experiment or procedure in a laboratory. Our fume hoods capture the fumes released during an experiment by drawing fresh air from the environment, past the user into the unit.. This way the concentration of the chemical fumes/effluents are kept at the minimum possible levels in and around the breathing zone of the user. The vector of the air in the fume hood points to the inward direction and perpendicular to the face of the user. The velocity of the air is controlled at approximately 80 feet per minute, so as to control the particle kinetics of various aerosols and diffused gases. Features: Ergonomic Design Energy Efficient Mechanism Low Noise Levels Conforms To ASHRAE-110-1995 (British Standard) Testing Method. Construction Details: Our fume hoods are developed to be used as semi closed ventilated enclosures so as to protect the user from harmful and toxic fumes and vapors and to eliminate the possibility of accidental fire, which may be resulted due to the emission of inflammable gases during the course of a given experiment. Hence the material of construction of all our fume hoods are carefully chosen S.S-316 grade/ M.S duly Powder Coated. The work table is made of heavy gauges SS-316. Our entire fume hoods are provided with sliding sash made out of special grade shatter proof temper glass duly framed in aluminum frame with sliding motion and counter weight balanced mechanism. Our units ensure minimum illumination level of approx 800 lux on the work table. The unit is equipped very diligent heavy duty exhaust system, comprising of dynamically balanced centrifugal impeller with high speed motor of approx 1440 RPM (Heavy Duty 1/4 H.P A.C Motor/ 1/2 H.P A.C Motor/ 1 H.P A.C Motor/ 1.5 H.P A.C Motor ).
Best Deals from Laboratory Hood
Fume Hood
Get Price Quote
1 piece (MOQ)
Thick Wooden Board Fabricated, Outer is Finished with Laminated Mica and Inner Duly painted, Designed So as Throw Out all Toxic/harmful Vapors, Thus Protecting Costly instruments and the Person Working in the Lab. Working Table Top is Fitted With stainless Steel Top, Provided with Ss Sink and Tap. the Front Door Moves Vertically up & Down with Concealed Counterbalanced Weight/by Hingers the Unit is Fitted with Flourescent Light and a Gas Cock For gas/air Supply. the Space Under the Work Station Can Be Provided with Switches For exhaust System and Flourescent Lights. Workable On 220 Volts Ac Supply. working Size 2'x2'x2' 4'x2'x2' 6'x2'x2' 5'x3'x3' 7'x3'x3' optional Accessories : pvc Fume Duct per frp/ss Lining Onworking Walls
Ambinova Fume Hood
Get Price Quote
1 piece (MOQ)
type-general purpose & acid digestion optional accessories-ducting pipe length-1219 depth-800 hood construction-steel with oven baked epoxy polyester coating base cabinet construction-steel with oven baked epoxy polyester coating
Fume Hoods
170,000 Per Piece
1 Piece (MOQ)
Laboratory Fume Hood
100,000 Per Piece
1 Piece (MOQ)
Fume Hood
85,000 - 250,000 Per Piece
1 Piece (MOQ)
Laboratory Fume Hood
95,000 Per Piece
1 Piece (MOQ)
Laboratory Fume Hood
Get Price Quote
We bring forth optimum quality Laboratory Fume Hood for the esteemed clients. The Laboratory Fume Hoods manufactured by us are designed with extreme precision using quality methods that make it suitable for use in various laboratories and research units of industries, institution etc. Our Laboratory Fume Hoods are non-conductor of heat and are chemical and corrosion resistant. The clients can avail our energy efficient Laboratory Fume Hood at very economical price. Made Of Wooden board laminatedMild steelStainless steelTiled work station, reinforced fibre Technical Specifications Sliding sash doorWash basinExhaust systemWork on 220V AC Size 600x 900x 1200 mm
Fume Hood
55,000 Per Piece
1 Piece (MOQ)
ductless fume hood
Get Price Quote
Model 670 Fume Hood Monitor
12,500 Per Piece
4 Piece(s) (MOQ)
Laboratory Fume Hood
85,000 - 225,000 Per Each
1 EACH (MOQ)
Chemical Fume Hood
85,000 Per Piece
1 Piece (MOQ)
fabricated thick mild steel/stainless steel duly powder coated painted. Working table top is fitted with black granite and three side wall fitted with highlem sheet (acid proof) a small wash basin with connections provided for inlet and outlet of water. The front door moves vertically up and down with concealed counter balanced weight. The unit if fitted with fluorescent light and a gas and water tap supply. The space under the work station can be provided with storage compartments for storage purpose. The front facing panel is fitted with 15/5 amp socket with switches for exhaust system and fluorescent light. To work on 220/230 volts a. C. Supply.
Laboratory Fume Hood
Get Price Quote
Based in Delhi, we are a prominent Laboratory Fume Hood Manufacturer and Supplier. Laboratory Fume Hood is used in laboratories for protecting them from hazardous chemical gases and acid fumes. Conforming the set industry standards, our Laboratory Fume Hood is designed in different specifications to meet diverse requirements of the customers.
Laboratory Fume Hood
Get Price Quote
Laboratory Fume Hoods
Get Price Quote
Laboratory Fume Hoods are an ideal health and safety care measure. The company provides Laboratory Fume Hoods to control the transfusion of toxic chemicals in laboratories. The Laboratory Fume Hoods, we offer, are constructed in accurate structures. Our Laboratory Fume Hoods are designed in compliance with the standards set by professionals, for their proper construction.
Fume Hood
Get Price Quote
We are recognized as one of the reputable Manufacturers, Exporters and Suppliers of Fume Hood in Delhi, India. High-grade metal is used in the manufacturing of the Fume Hood ensuring high durability, tensile strength and resistivity to adverse conditions. We stock the Fume Hood in the spacious warehouse to address the bulk requirement of buyers easily. More about Fume Hood : A fume hood or fume cupboard is a type of local ventilation device that is designed to limit exposure to hazardous or toxic fumes, vapors or dusts. In the fume hood air is drawn in from the front (open) side of the cabinet, and either expelled outside the building or made safe through filtration and fed back into the room. Purposes : To protect the user from inhaling toxic gases (fume hoods, biosafety cabinets, glove boxes); To protect the product or experiment (biosafety cabinets, glove boxes); To protect the environment (recirculation fume hoods, certain biosafety cabinets, and any other type when fitted with appropriate filters in the exhaust airstreams). Features : Highly recommended for exhaust of toxic gases, acidic/alkaline fumes, chemical vapors, removable of odour etc from the hood working area. Very useful for products and personal protection, reducing odour levels in laboratories and protect costly lab equipments. Complete exhaust motor blower assembly generated a negative pressure inside the hood thus facilitating removal of all contaminants from the works area, into the atmosphere. Main cabinet/body is fabricated out of Mild Steel from outside & S.S 304 grade inside. Work table is made of Mild Steel and is fitted with a small S.S. sink with water tap connections. The front door moves vertically up and down with concealed counter balanced weight. The unit is fitted with fluorescent light and a gas cock for gas/air supply. The front facing panel is fitted with 15/5 Amp socket with switched for exhaust system and fluorescent light. To work on 220 / 230 volts A.C. Supply.
Chemical Fume Hood
Get Price Quote
The fume hood is an important safety device in any laboratory. Fume Hoods are recommended for exhaust from the hood working area, of gases, vapour, toxic particles, odour to improve working environment of people who regularly handle toxic substances. These reduce personal exposures and odour level in the laboratory. These are designed to exhaust toxic or otherwise harmful vapours etc., for protecting laboratory personnel & equipments. A motor-blower exhaust system generates negative pressure within the hood, extracting the contaminated air from the work area and expelling it into the atmosphere and preventing the fumes from escaping into the room. These are recommended for various laboratories like Bio-Chemistry, Pharmaceutical units, printed circuit etchingcleaning etc. These are capable of handling corrosive fumes of sulphuric and hydrochloric acids etc. If work-area walls are lead-lined (Optional), it can be effectively used for Radio-Isotopic applications.
Fume Hood
85,000 - 250,000 Per Piece
1 Piece (MOQ)
Fume Hood for AAS
Get Price Quote
We are one of the renowned wholesalers and exporters of Fume Hoods. These products are widely used in various industrial applications. Manufactured from a high quality material like stainless steel, these products are equipped with blower and several other components.
Laboratory Fume Hoods
Get Price Quote
Laboratory Fume Hoods are one of the most important components used to protect laboratory personnel from exposure to hazardous chemicals and agents used in the laboratory. When used properly, they can provide an effective backup safety device for the containment and exhaust of toxic, offensive or flammable materials when the containment of an experiment or procedure fails and vapors or dust escape from the apparatus being used. We are one of the foremost Chemical Fume Hood Manufacturers and Stainless Steel Fume Hood Suppliers. The Cabinet is made of thick ply board & reinforced with teak wood whatever necessary interiors coated with asbestos sheets, coated with epoxy paint or convert FRP lining as per requirements. Working table is covered with glazed ceramic tiles and provided with necessary water inlet & outlets with sink (stainless steel/prosaleen). Provision of water inlet/outlet, sink will be on request only. Front door is made of 6mm clear glass in laminated teakwood frame and connected with a counter weight balance through a iron rope. The door will have the provision of vertical sliding facility. Exhaust blower consists of single phase motor, directly connected with a PVC Exhaust blower consists of single phase motor, directly connected with a PVC impeller and enclosed in a epoxy coated MS casing. The rating, speed & capacity of the Blower sill are designed on the basis of the SIZE & VOLUME of the FUME HOOD. However the suction velocity of the FUME HOOD will be around 100 cfm per square feet. The exhaust assembly can be of build-in-type or external mount type. The blower assembly will directly be connected with suitable exhaust ducting, which is made of PVC pipes with suitable bend & joints and rain guard. Chemical & Fire resistant Phenolic(FRP) Resin Lining inside the Chamber Different choice of worktops suitable for a wide range of applications (S.S/ GRANITE/TILES) Clear tempered safety glass sash utilizes counter weights for smooth and effortless operations Options : Compact Ductwork System with Exhaust Fan Fume Scrubber Wash-Down System Electrical Wiring Solvent Storage Base Cabinet Acid Storage Base Cabinet Fire Proof Tiles
Fume Hood
Get Price Quote
Obromax fume hood are to limit a person's exposure to hazardous andor unpleasant fumes. For worker protection, the laboratory fume hood is the most useful piece of safety equipment found in the lab. When used appropriately, fume hoods not only provide protection from toxic gases and vapors but also provide protection from unanticipated fires and explosions. Fabricated out of thick wooden board these are designed . Outer is finished with sunmica and inner epoxy painted. Working table top is fitted with acidalkali resistant tiles stainless steel and a small wash basin with connections provided for inlet and out let of water. The front door moves vertically up and down with concealed counter balanced weight. The unit if fitted with flourescent light and a gas cock for gasair supply. The space under the work station can be provided with storage compartments for storage purpose. The front facing panel is fitted with 155 amp socket with switches for exhaust system and fluorescent light. To work on 220230 volts a.c. Supply. Working size- 2’x2’x2’ 3’x2’x2’ 4’x2’x2’ 6’x2’x2’
Chemical Fume Hood
Get Price Quote
Laboratory Fume Hood Stations by Bionics Scientific are available in various sizes and dimensions to meet specific requirements of your research. These fume hoods have a choice of vertical or horizontal sliding sash and MS or stainless steel construction. The standard sizes of our fume hoods are available in most demanded requirements (4ft, 5 ft, 6 ft & 8 ft). Often known as chemical fume hood, these systems also dilute effect on flammable gases and vapors. Our product range includes general purpose fume hoods, ductless fume hoods, and mobile units; designed with number of optional features and specifications required to meet critical challenges in laboratory research areas worldwide.
Fume Hoods
Get Price Quote
Fume Hood Ceiling
Get Price Quote
Fume Hoods
Get Price Quote
Fume Hood are manufactured according to American Design Standard: ASHRAE 110: 1995 & European Design Standard: EN-14175. We have offered 3 modules for Fume Hood, 4’, 5’, & 6’. The exterior construction is powder coated durable (70 – 80 microns), 1.5mm & 1.2mm heavy duty CRCA (as per IS: 513) sheets with rigid. The interior construction is chemical & heat resistant, 6mm thick Polypropylene, smooth finish. The working top is of 18-20mm Jet Black Granite. Worktop is provided with 100mm x 200mm sink for drainage with water tap. Fitted with Level adjusting screws to adjust Fume Hood level by + 10mm. Air Flow Monitor (Optional) is an accessory for Fume Hood. This is to indicate the approx. face velocity of airflow. Air Flow can be regulated by ‘Flow Control Value’. The Noise Level is < 70db at 1 meter from the Fume Hood. An Apparatus Holding Grid (optional) can be provided which is made of Duralumin rod (Dia. 12.7 mm) to hold the apparatus. Chemical Storage Base Cabinet can optionaly be provided. Fume Hoods are constructed double walled which provides access to services like Electricity, Gas & Water. We use high quality HDPE/PPGL/FRP/PP/PVC pipes for FC ducting. We are using Silent PP + FRP high efficiency centrifugal blower for exhaust system. This is heat & chemical resistant PP + FRP blower with aerodynamically balanced impeller. Air Suction Capacity of the blower is 800 CFM confirming to international face velocity norms. Motor fitted is 1HP (3 Phase), direct drive, continuous rating as per IS 325 we prefer cromption.
Fume Hood
Get Price Quote
Fume Hood Roch Mechatronics Inc Fume Hood are designed for:. Durable, Hazardous Chemical Gas Removal Wide variety of Material for User Selection Slide Type Door with acrynic/Tempered Safety Glass Powerful exhaust Fan Blower Built-In Utility cabinaet Application based work plateform, SS/granite/ceramic tiled
Laboratory hoods
6,000 Per units
Fume Hood
Get Price Quote
We are offering fume hood. Labsol laboratory fume hood is a ventilated enclosure designed to contain and exhaust fumes, vapors, mists and particulate matter generated within the hood interior. Fume hood structures are basically boxlike, with an open side (or sides) for access to the interior of the hood. A transparent, movable panel, called a sash, allows the user to restrict or enlarge the hood opening. The hood is connected, via ductwork, to an exhaust fan, usually located on the roof of the building in which the hood is located. The exhaust fan draws air from the room in which the hood is in through the hood opening and out through the ductwork. The speed of the air moving through the hood opening is known as face velocity. labsol fume hood is fabricated from special grade pre coated mild steel sheet duly powder coated from outside and epoxy painted from inside. The inner walls of the working chamber is covered with epoxy coated asbestos or frp or hdpe lining or as required which duly provides better protection from acid fumes in the lab. labsol fume hoods are aerodynamically designed considering most efficient airflow to the suction. Double wall feature provides easy access to utilities like water, gas, vacuum & electricity. Detachable base storage cabinets are provided with castors for easy maintenance, sigma offers variety of lining & work surfaces like granite, ceramic, s.s., p. P. & frp. Sash is provided with 6 mm toughened glass & counter balance is provided to achieve easy movement. High performance centrifugal blower is provided with different ducting materials like pppvchdpe etc. Baffle removable plates incorporated into the rear or top of the work chamber to form a plenum between the work chamber and the exhaust duct connection to promote uniform scavenging of fume and the point of discharge. Exhaust system all exhaust air ductwork, fan and associated equipment installed between the point of connection to the fume hood and the point of discharge.