Horizontal laminar flow cabinet
Get Price Quote
Designed so as to meet the requirement of US Federal Standard 209 B (BS 5295) providing free air to meet class 100 (class conditions) the cabinets are fabricated out of thick board duly sunmica clad. Interior surface are epoxy painted for its longer life. The work table is made of thick board which is sunmica clad at top. Side panels are made out of thick transparent plexi glass duly framed. The unit is fitted with pre filter and is made to pass through highly effective HEPA (High Efficiency Particular Air). Filters having efficiency rating as high as 99.99% with cold DOP and 99.97% with hot DOP, thus retaining all air borne particles of size 0.3 micron and larger. Using a dynamic machine, the blower and motor assembly is statically and dynamically balanced ISI Marked motor of ¼ H.P. capacity operates with minimum noise level. The working area is illuminated by fluorescent lighting fitted to the unit. Height of the working table provides comfortable "SIT DOWN" working position for the operator. To work on 220/230 volts A.C. supply. Supplied complete with sunmica table top. HEPA filters, pre-filter and fluorescent illumination. Transparent front door, static pressure manometer, Built in Germicidal light, cock for gas, air or vacuum line. Etc.
laminar air flow vertical
Get Price Quote
Features: Vertical Laminar Air Flow Benches are used for various works that require maintenance of the cleaness and purity like plant tissue culture, examination and experimentation of precision electronic parts, medical science, pharmacy, agriculture sector and the like. Designed so as to meet the requirement of US Federal Standard 209 B (BS 5295) providing particle free air to meet class 100 conditions. Cabinet is fabricated of Wooden board laminated with sunmica OR Cold rolled steel duly powder coated OR Stainless Steel (SS-304) (as ordered). Working table is made of Stainless Steel Sheet (SS-304 grade). Side panels and front door are made out of thick transparent plexi glass. Air drawn through pre-filter is made to pass through highly effective HEPA (High Efficiency Particular Air)filters having efficiency rating as high as 99.99% with cold DOP and 99.97% with hot DOP, thus retaining air-borne particles of size 0.3 micron and larger. Heavy Duty Motor operates with minimum noise level. Using a dynamic machine, the blower and motor assembly is statically & dynamically balanced. Working area is illuminated by fluroescent lighting fitted to the unit. Supplied complete with S.S. Table Top, Transparent front door, Static Pressure Manometer Built in U.V. Germicidal Light and Cock for gas, air or vacuum line, HEPA filters and pre filter. The highly efficient HEPA filter maintains the optimum cleanliness and purity. The prefilter fitted extends the life of HEPA filter drastically. Silent Vibration-Free Blower ensure noiseless operation and anti-vibration construction provides efficient working environment. To work on 220/230 volts A.C. supply. options Front door made of transparent POLYCARBONATE SHEET in lieu of plexi glass to cost extra. Magnehelic pressure differential gauge (to track filter Pressure) in lieu of static pressure manometer. Electronic filter choke alarm (differential pressure monitor). Hour meter totalizer for life used for U.V. light. Interlocking of U.V. Germicidal tube & fluorescent light with auto switch off/on mode for motor blower when the door is closed/open. Microprocessor LCD Controller with Auto Switch off mode for motor blower when door is closed. Digital buzzer timer sounds an audio alarm on completion of sterilizing time of the chamber and switches off U.V. germicidal tube and automatically switches ON the fluorescent light,alerting the user that the bench is ready for use.
Best Deals from Laminar Air Flow
Vertical Laminar Air Flow
Get Price Quote
We are enlisted as one amidst the forefront Stainless Steel Laminar Air Flow Various national clients are placing repeated orders for the Vertical Laminar Air Flow due to the unmatched quality and unsurpassable performance. Additionally, the Vertical Laminar Air Flow Cabinets are loaded with advanced features confirming to the international standards.
Laminar Air Flow
Get Price Quote
We are offering Laminar Air Flow. we are engaged in manufacturing high grade laminar air flow that is in huge demand in the national as well as international markets. using optimum quality components, we develop laminar flow having higher friction effect. accessories : 1/4 hp motor on hookss tableuv fitted0.03microne hepa flow regime : high momentum diffusionlow momentum convection technical specifications : size : 2’x2’x2’to 6’x2’x’2’shapes : vertical and horizontal ideal for : hospitalsmedical clinicsnursing homesmedical colleges.
Laminar Air Flow
Get Price Quote
Laminar Air Flow Table provides air flow in the work area for operations where product is of utmost importance. Laminar flow principles include double filtration of air. Herein, atmospheric air is drawn by pre-filters through heavy duty blowers afterwards air is passed by extremely effective HEPA (High Efficiency Particular Air) filters which filter almost all air borne particles of size as small as 0.3 micron and larger. Double filtered laminar flow air blows through the work table, at a nominal controlled velocity of approx. 90 feet / min. It is supplied with stainless steel table top, transparent front door, flexi glass, built in U.V. light, static pressure inclined manometer, built in supply cocks for air, gas, or vacuum lines. Available In Following Sizes Working area 2 x 2 x 2, size of HEPA filter 2 x 2 x 6 Working area 3 x 2 x 2, size of HEPA filter 3 x 2 x 6 Working area 4 x 2 x 2, size of HEPA filter 4 x 2 x 6 Working area 6 x 2 x 2, size of HEPA filter 6 x 2 x 6
HORIZONTAL LAMINAR AIR FLOW CABINET (MICROPROCESSOR CONTROLLED MSW-161
Get Price Quote
It is used for various works that require maintenance of the cleanliness and purity like plant tissue culture, examination and experimentation of precision electronics parts, medical sciences, pharmacy, agriculture sector and the like. Designed so as to meet the requirements of US Federal Standard 209 B (BS 5295) providing particle free air to meet class 100 conditions. Cabinets is fabricated of wooden board laminated with sunmica OR cold rolled steel duly powder coated OR electro galvanized steel OR stainless steel (SS-304grade) (as ordered). Working table is made of Stainless Steel Sheet (SS-304 grade). Side panels and front doors are made out of thick transparent plexi glass.Air drawn through pre-filter is made to pass through highly effective HEPA (High Efficiency Particular Air) filters having efficiency rating as high as 99.99% with cold DOP and 99.97% with hot DOP, thus retaining all air-borne particles of size 0.3 micron and larger. Heavy Duty Motor operates with minimum noise level. Working area is illuminated by fluorescent lighting fitted to the unit. Supplied complete with S.S. Satin finish Table Top, Transparent front door, Static Pressure Manometer, Built in U.V. Germicidal light and Cock for gas, air or vacuum line, HEPA filters and pre-filter. The highly efficient HEPA filter maintains the optimum cleanliness and purity. The prefilter fitted extends the life of HEPA filter drastically. Silent Vibration-Free Blower ensures noiseless operation and anti-vibration construction provides efficient working environment.Interlocking of U.V. Germicidal Tube & Fluorescent Light with auto switch off/on Mode for blower when the door is closed/open. All units with MOC : Wooden/CRC/EGS/Stainless Steel are mounted on a heavy duty mild steel stand duly powder coated. To work on 220/230 volts A.C. supply. CONTROL & AUTOMATION Equipped with Microprocessor controller having alphanumeric display and soft touch controls. Controller indicates input, status, alarm function and control for blower, lights outlet and UV. Continuous monitoring through bright easy to read LCD panel Password Protection for authorized operation. Real time Clock UV timer showing used time and balance available life in hours. Total HEPA Filter time showing used time and balance available life in hours. HEPA filter choke alarm after HEPA filter life is over. UV light/Door/Fluorescent Light Inter Lock, i.e. UV switches ON only When door is closed, and automatically switches OFF fluorescent lights. If UV light is on & the operator tries to open the door, it raises audio visual alarm. Built-in RFI and electrical noise filters eliminate interference with adjacent instrumentation.
horizontal laminar flow cabinets
Get Price Quote
horizontal laminar flow cabinets, auto claves, Bacteriological Incubators
Laminar Air Flow
Get Price Quote
We are offering OBROMAX laminar Air Flow is designed so as to meet the requirements of US Federal Standard 209 B (BS 5295) providing particle free air to meet class 100. OBROMAX laminar Air Flow also called laminar hood is an enclosed bench which is designed to provide air flow vertically or horizontally in a way to protect all laboratories or raserch work from contaminants and suspended particles which can reduce the efficiency or may destroy the results of research or laboratory work. OBROMAX LAF is a closed cabinet which is mainly constructed from high grade stainless steel or without any gap so that there would be any joints or gap where suspended particles can accumulate. Air is drawn through HEPA (high efficiency particulate air filters) or ULPA (ultra efficiency particulate air filters) filters in a stream line flow to protect personnel and products OBROMAX Laminar air flow is equipped with a shortwave UV germicidal lamp for sterilization of working platform or cabinet, which should be turned on about 10-15 minutes before using the hood to kill the germs or to sterilize the working environment.
Laminar Flow Bench
Get Price Quote
Laminar Flow Bench, Separatory Funnel, Extraction Mantle
Laminar Air Flow
Get Price Quote
Laminar Air Flow, Autoclave, Kjeldahl Distillation Unit, Ice Flaking Machine
Laminar Air Flow
Get Price Quote
Laminar Air Flow, Autoclave, Pharmacy, Sieves, tablet testing instruments