Ventilator Machine Dealers in Sant Nagar, Delhi

(7 products available)
  • BiPAP A30 Bi-level ventilator

    BiPAP A30 Bi-level ventilator

    Get Price Quote

    • Color: White,White
    • Condition: New
    • Power Source: Electric
    • Application: Hospital
    • Feature: High Quality
    • Type: Bipap Machine
    • Warranty: 2 Yrs
    • Brand Name: PHILIPS RESPIRONIC
    • Warranty: 2 YEARS

    nspired by you and your patients, the bi-level ventilator BiPAP A30 has been designed to combine ease-of-use with technology advancements that adapt to your patient’s condition to deliver enhanced therapy. Natural performance for a smooth transition from hospital to home for your chronic insufficiency respiratory patients.

    more..
  • Ventilator Circuit With Double Water Trap & Catheter Mount

    Ventilator Circuit With Double Water Trap & Catheter Mount

    Get Price Quote

    • Application: Clinical Purpose, Hospital
    • Brand Name: Medisafe International
    • Model: Reusable Ventilator Circuit
    • Item Code: MSI - 1089
    more..
  • Best Deals from Ventilator Machine

  • pvc double lumen endobronchial tube

    pvc double lumen endobronchial tube

    3,350 - 3,950 Per piece

    500 piece (MOQ)

    • Type: Surgical
    • Brand Name: MEDTRONICS
    • Material: PVC
    • Application: HOSPITAL
    • Brand Name: MEDTRONIC
    • Size: 28 Fr

    A double-lumen tube (DLT) is an endotracheal tube designed to isolate the lungs anatomically and physiologically. Double-lumen tubes (DLTs) are the most commonly used tubes to provide independent ventilation for each lung. One-lung ventilation (OLV) or lung isolation is the mechanical and functional separation of the 2 lungs to allow selective ventilation of only one lung. The other lung that is not being ventilated passively deflates or is displaced by the surgeon to facilitate surgical exposure for non-cardiac operations in the chest such as thoracic, esophageal, aortic and spine procedures. This activity reviews the use of the DLT, its indications, contraindications, and complications in thoracic surgery.

    more..
  • Endotracheal tube (Cuffed)

    Endotracheal tube (Cuffed)

    Get Price Quote

    Endotracheal tube (Cuffed) Introduction • Tubular device designed to be introduced into the trachea via the mouth or nose to secure the airway and maintain the gas exchange in the lungs. Areas of Use • Anaesthesia (Operation theatres) • Emergency Medicine • Trauma and airway management Tube • Made up of non toxic, clear, transparent, thermoresistant medical grade Polyvinyl Chloride. • Fitted with standard 15 mm connector for attachments to all standard ventilator circuits in operation theatres or intensive care units. • Graduated markings to display distance from the tip. • Well marked to indicate the size (internal diameter in mm, outer diameter in mm) • Nasoral tip suitable for nasal/ oral inhabitation. Pilot balloon • Attached to the main tube to inflate the cuff. • Integrated one way Silicone spring valve with luer lock to ensure one way air flow. • Distinguishable markings on the pilot balloon to indicate the size of the tube and the maximum allowable pressure of the cuff. Cuff • High volume, low pressure, evenly shaped integrated with the tube. • Minimizes displacement of the tube once inserted into the airway and protects the patient from pulmonary aspiration. Others • Radio opaque lining from tip to end to detect proper placement of the tube. • Murphy’s Eye near the tip to circumvent any obstruction due to foreign body impaction. • EO gas sterilization, unit packaged, disposable after use. Options available • Adult / Paediatric • Cuffed / Non Cuffed Sizes and technical specifications Ref./Art No. (E.T. Tube with plain bevel) I.D.(mm) Packing inner/outer units Ref./Art No.(E.T. Tubewith Murphys’ eye) Packing inner/outer units Peel open Soft blister Peel open Soft blister 6200605 6200603 6.0 5/200 6210605 6210603 25/200 6200655 6200653 6.5 5/200 6210655 6210653 25/200 6200705 6200703 7.0 25/200 6210705 6210703 25/200 6200755 6200753 7.5 5/200 6210755 6210753 25/200 6200805 6200803 8.0 5/200 6210805 6210803 25/200

    more..
  • ICU Ventilator

    ICU Ventilator

    Get Price Quote

    We are instrumental in bringing forth the ICU Ventilator that is widely used at hospitals and nursing homes. The cutting edge ICU Ventilator can be availed from us, which is known for its efficiency. The company is a renowned ICU Ventilator Manufacturer, Importer and Supplier in India. This Ventilator is especially designed by qualified professionals, who are well-aware about the new technological advancements. Our ICU Ventilator is available in diverse specifications and models, at the market leading prices. The Main Characteristics of Vivo Ventilator It is capable of treating patients from neonates to adultsIt has 10.7 Inch colorful monitorExclusive distance visualization (InterNet and IntraNet)"Roll-over" knob - easy adaptation to the userUp-to-date modes of ventilatory supportVolume-Controlled (VCV) Assist/ControlPressure-Controlled (PCV) Assist/ControlPressure Support (PSV)CPAP + PSVSIMV'(VCV} + PSVSIMV (PCV) + PSVMandatory Minute Ventilation (MMV) + PSVPSV + Tidal Volume AssuredPositive Biphasic Pressure (APRV)Continuous flow. time cycled. pressure limited.(neo}Non-Invasive Ventilation Unique Watchdog Feature Watchdog is an independent system of function vigilance of the electronic circuit. It is not related with Back-up ventilation and has a ventilatory mode by pressure control (PCV) permanent and pre-programmed in the factory, Entrance Inaction Soon after 30 seconds when turning on the ventilator and the first screen is not accepted to pass the calibration ofthe respiratory circuit.When the microprocessor loses the program sequence control that regulates the ventilation. The entrance in active action activates a signal that produces the beginning ofthis mode of emergency ventilation. Emergency Ventilation The ventilator is activated, for any category (adult, paediatric), the following ventilation form Ventilatory mode: By pressure (PCV). Cannot be changed .Inspiratory Pressure (PCV): 15 cmH20. The value can be changed.Rise Time: With 25% to all the categories .Inspiratory Time: 0.8 sec ..The value can be changed.Frequency: 15 rpm. The value can be changed.Sensitivity by pressure: -1.5 cmH20.Fi02: 100%. Disabled for change.PEEP: 0 (zero). disabledSilence control: Enabled.High Pressure alarm: 30 cmH20. The value can be changed.Low Pressure Alarm: 5 cmH20. The value can be changed.Alarm and values ofVT (min and max) and Ve: Disabled.Monitor handling: Disabled. Specifications Classification : The VIVO is a microprocessor based, pressure or flowcontroller, with pressure. flow or manual trigger It IS pressure, volume or flow limited. It can combine pressure and flow control in each breath.ControlsFIO: 0.21 10Inspiratory Time : 0 1·3 secondsI:ERatio : VCV'11-120IPCV 51-1.20Respiratory Rate : 1-180 rpmTidal Volume : 10 - 2500 mL.Sensitivity (PEEP compensated) : Trigger flow 0.5 to 5 Umin I Trigger pressure. -0.5 -10 cm H O.Pressure Control (PCV) : 3-80 cm H 0 ( with Rise Time).Pressure Support (PSV) : 0-80 cm H 0 ( with Rise Time).Expiratory Sensivity : 5,10, 15, 25(default), 33, or 40% of the peak flow.PEEP/CPAP 0-50 cm H 0Nebulizer Functional during inspiration onlyInspiratory flow : In VCV Automatic regulation Iin PCV and PSV up to 200 t/rnin.Sigh (VCV only) : Number, Events per hour, Volume, and Max.PressureInspiratory Pause(Hold) (VCV only) : 0.25 to 2 seconds.Manual Breath : For an inspiration or sigh.02 100%: pre and post oxygenation for suction. 120 s with 30 s in the middle for suctionWaveflow form (VCV) : Square, descending ramp, sine and ascending ramp.Standby : To stop the ventilator and saving the selected parametersTCP/IP exit : For external communication.(optional)Measured Parameters : Airway Pressure. Peak, Plateau, Mean, Base I Peak Flow I Expiratory Time Inspiratory Time and I:E Ratio of spontaneous breaths I Expired Tidal Volume Expired Minute Volume I Inspired Fi02 (optional)Alarms : High and Low Inspiratory Pressure, High and Low Tidal Volume, Apnea, High and Low Minute Volume, High breathing rate, High and Low PEEP, Low and High Fi02 (optional), Gas Supply Failure [Low Battery] Power Loss, TechnicalThe eteans are ecuvetea accordmg to levels of priorities with audible and visual messages on the screen Each event is documented in a uet With date and hour, The equipment also has a emergency ventitetion called 'Watchdog"Respiratory Mechanics : This option allows the determination of: AutoPEEP I Dynamic and Static Compliance I Static and Dynamic Resistance I Slow Vital Capacity I PO.1Graphic Display (Screen) : Selection of pressure, volume and flow vs. time wave forms, and pressure/volume and flow/volume loops I frozen Image I Sweep speed selection of horizontal axis and scale for vertical axis I Trend of tidal volume, rate, peak and base pressure peak flow and dynamic compliance I Pressure bar showing airway I access in the distance for InterNet or IntraNet.(optional)ElectricalVoltage Range : 100 a 240 Volts (auto switching)Frequency : 50 - 60 HzPower : 30 WattsInternal Battery : 4 hours

    more..
  • Ventilators

    Get Price Quote

    monitors, Ultrasound, pluse oximeter

    more..
  • Endotracheal Tube

    Get Price Quote

    Urology Products, Suction Catheters, Tracheostomy Tube, Colostomy Bag

    more..
Filter by Locality
top