Medilife Technologies Kalkaji, Delhi

  • Molecular Resonance Generator

    Molecular Resonance Generator

    Request for Price

    Molecular Resonance Generator (R) – Vesalius MC/MCN Plus/ Quantum Vesalius MC – Molecular resonance electrosurgical unit / bipolar cutting / monopolar cutting / bipolar coagulation.  Main Features: Resonance Technology, 4-16 MHz. 45⁰ Centigrade for cutting, 65⁰ Centigrade for coagulation. Very low working temperature. No lateral heat. No irrigation needed. No Eschar Better heating of the tissue. Possibility to cut the skin. Ideal for delicate surgeries. Total absence of neuromuscular stimulation. Very Low blood loss. Reduced intra-operative time.   Description QMR TECHNOLOGY APPLIED TO SURGERY Quantum Molecular Resonance Technology (QMR) is used in surgical devices through the product lines Vesalius®, Quantum® and Essential®. These are excellent tools that allow the surgeon to operate with the greatest care and respect of the surrounding structures and tissues. Unlike the traditional electro and radiosurgery, which base its working principle on a mere transfer of thermal energy (heat generated by the flow of electric current), our devices employ a spectrum of frequencies such that the transferred energy translates only minimally in thermal rise; the predominant component of energy transmitted to the tissue interacts directly at the level of molecular bonds, breaking them up in a non-thermic way. This effect is obtained thanks to the fact that the frequencies used by our scalpels are extremely high (ranging between 4MHz to 16 MHz) and of specific values, which proved to be extremely effective for the purpose. The effect of resonance with the molecular bonds is of extreme importance in order to obtain the desired results (breaking up of molecular bonds and considerably limiting the heat transfer). To understand the importance of the role that plays the resonance effect, consider the example of crystal glass that shatters when it is hit by a sound wave of appropriate frequency. As it is well known, the breaking of the glass is not so much dependent on the intensity of the incident sound wave but from the fact that it is perfectly modulated on the resonance frequency of the glass itself. The use of the QMR scalpel allows to obtain an extremely precise and delicate cut. It is estimated that the temperature on the tissue adjacent to the cut does not exceed 45° C. Even the coagulation is obtained by exploiting the same working principle. In this case however, it is estimated that the increase in temperature on the tissue is limited to 65° C Quantum is the QMR Generator specifically designed for ENT Surgery. It has a wide range of both single use and multiple use electrodes which can be operated either in monopolar or bipolar function. Quantum uses an impedence control which helps the surgeon to deliver the right amount of energy. The wide range of electrodes allow Quantum to be used in many different operations, as: Turbinate reduction, Uvopalatoplasty, Tongue base reduction, Tonsil reduction, Tonsillectomy, Parotidectomy, neck evacuation with Galileo bipolar forceps, Adenoidectomy, Middle ear microsurgery.

    ...more
    Get Best Price
  • diagnostic abr equipment

    diagnostic abr equipment

    Request for Price

    Description All-in-one Solution for ABR, ASSR, Multi-ASSR, MLR, LLR/CAEP, TEOAE, DPOAE, SOAE, ECochG, VEMP, P300, MMN and Other Tests A full range of objective and subjective techniques for the diagnostics of acoustic and vestibular analyzer affection, hearing threshold search is in one small unit now! Using this device you can perform ABR, ASSR, multi-ASSR, M LR, LLR/CAEP, TEOAE, DPOAE, SOAE, ECochG, VEMP, P300, MMN, pure tone audiometry techniques easily. Automatic Multi-ASSR Test Multi-ASSR test implemented in Neuro-Audio system allows minimizing test duration due to automatization (intensity switching for hearing threshold search), stimulation of both ears simultaneously using 8 carrier frequencies (4 in each ear, from 500 Hz to 4000 Hz, ), use of frequency-specific Chirp stimulus which takes into account the cochlear anatomy for the response amplitude increase. Test result is represented as estimated pure tone audiogram used further for hearing aid fitting. High Acquisition Quality Well-considered system characteristics (low level of amplifier noise) and software features (adaptive notch filter, weighted averaging, Chirp stimulus, calculation of statistical parameters of signal and noise, up-to-date algorithms for automatic response detection) help a physician to obtain a high-quality record quickly. All tests can be performed when patient is awake (not-sedated). VEMP with Biofeedback Neuro-Audio system ensures full state-of-the-art support of VEMP tests, including VEMP with biofeedback, VEMP amplitude correction by mean EMG activity level, and also a unique function of EMG histogram with the possibility of post-hoc analysis (important for children). Acquisition of bone-conduction VEMP is also possible using bone vibrator amplifier (separate unit) and B-71 bone vibrator. Supported technique variants: cVEMP (cervical), oVEMP (ocular), gVEMP (galvanic).

    ...more
    Get Best Price
  • Co2 Laser

    Co2 Laser

    Request for Price

    Main Features: For wide range of applications For non-contact surgery, vaporisation and coagulation Radiation of 10600nm wavelength Power of the radiation can be regulated in scope of 0-15W or 0-25W   Description The CO2Azuryt CTL 1401 is a medical unit designed for a wide range of applications e.g. in dentistry, laryngology, dermatology, esthetical surgery, gynaecology, general surgery, oncology, and many others. It is intended for a non-contact surgery, vaporisation and coagulation. Active media in the form of CO2 gas is the source of treatment radiation in this laser. The radiation of 10600nm wavelength, invisible for a human eye is absorbed quite well by water and soft biological tissues. Power of the radiation can be regulated in scope of 0-15 W or 0-25 W (depending on version). The focused laser beam causes vaporisation of the target tissue, closing blood and lymphatic vessels at the same time. Thanks to the adjusted laser parameters the patient’s pain during the treatment is minimised. Due to the special features of laser radiation as well as precise and non-contact method of its application, the laser device Azuryt  CTL 1401 is extremely useful and often irreplaceable working instrument in a modern consulting room.

    ...more
    Get Best Price
  • Clinical Audiometer Machine

    Clinical Audiometer Machine

    Request for Price

    Get Best Price
  • OAE SCREENER

    OAE SCREENER

    Request for Price

    NEURO-AUDIO-SCREEN – portable hearing screening system for Newborns and Infants. Main Features:  Three-in-one: TEOAE, DPOAE and ABR. User-friendly interface with touchscreen. Hearing screening in noisy environment. ABR curve with wave V marker. Results printed on portable printer.     Description Why is it Important? The hearing impairment is diagnosed in three of every thousand babies born, that is twice more than frequency of cleft lip (palate), twice more than frequency of Down’s syndrome and ten times more than frequency of phenylketonuria. The problem of diagnostics and treatment of hearing loss and deafness in this special category of patients is actual both in medical and social relations. Often the visual examination and other traditional diagnostic techniques of hearing impairment detection do not reveal the problem until 1 to 3 years of age — which is well beyond the critical period (6 months) for healthy speech and language development. However, if a hearing impairment is identified and treated in its early stages, studies have shown that the child’s speech and language skills will be comparable to his or her normal-hearing peers. For these reasons, hearing screening at birth and routinely throughout childhood is extremely important. Timely and correct diagnosis provides an opportunity to start the hearing rehabilitation and child integration to speech environment as soon as possible. What Should be Done? Earlier to solve the specified problem, the hearing screening of newborns and babies was applied. It was based on the consideration of risk factors with the further examination of babies, included in the risk group, in specialized establishments. However, at such approach 50% of children drop out of sight. The only possible solution of the problem concerning early detection and rehabilitation of children suffering from hearing loss and deafness is introduction of hearing screening with the use of objective technologies in maternity hospitals and maternity departments of patient care institutions. At present time, the fundamentally new so called objective techniques of hearing study are developed and applied in clinical practice, they are computer audiometry by auditory brainstem response (ABR) and recording of otoacoustic emission (OAE). It allows performing hearing study in any age, even in newborns. Device Usability The whole front panel of the device is 4.3″ touch screen. The menu with the list of available tests will be displayed on the screen after device switching on. You should insert OAE probe into a patient’s ear properly and start the test by touching the screen two times. The program will inform you if the OAE probe is inserted incorrectly. The test will be performed in automatic mode if everything is correct. After the test the program will give “PASS” or “REFER” result. It is quite simple. Detailed video guide supplied with Neuro-Audio-Screen will help you to master the program operation. The system is real easy to use even for untrained medical personnel including nursing staff. Wireless Bluetooth Interface Wireless Bluetooth Interface provides the opportunity to print exam results on wireless printer and export data saved in the device memory to the external computer with installed Neuro-Audio-Screen Manager. The program is supplied free with the device. Neuro-Audio-Screen Manager works on Windows-based computer. Using this program you can prepare a list of patients you plan to examine, export exams to the computer database, print results or export toNeuro-Audio.NET software. Customizable Settings You can change test settings using the configuration menu. For example, you can use different modes of OAE test: “Screening”, “Noisy (screening)”, etc. It helps to customize settings quickly in order to perform any hearing exam starting from screening in a noisy room and up to expert study in a specialized hospital.

    ...more
    Get Best Price
  • Diode Laser

    Diode Laser

    Request for Price

    Main Features: Integrated power meter for calibration. Video player feature. Green aiming beam. Touch Screen display. Low level therapy mode. Up to 12 W distal output power.   Description Exact and reliable The FOX from the A.R.C. Laser is the only calibrateable laser worldwide. No other system has such an advantage. FOX laser is the only one which can reliably provide you with the adjusted output power.FOX sets new standards in security. Training videos directly on the display Training videos can be saved on the USB stick, which is part of the standard delivery of FOX. The videos come up on the display as soon as you choose it in the menu.FOX is innovative Green aiming beam The green aiming beam of FOX laser improves the alignment and the exact sighting during the treatment.FOX gives you a better view Touch screen The modern color touch screen with a very simple guide: you can set and change the adjustments intuitionally. Mobile like your assistant The convenient battery operation allows implementing treatments everywhere and every time. You can transport the FOX in the helpful case to every place you need.FOX means flexibility Technical data:

    Weight : 1,2 kg operational

    ...more
    Get Best Price

Be first to Rate

Rate This

Select the service for which you are writing review for this business

How would you rate the business?

What would you like other to know about this business, based on your experience?

Minimum 20 characters!

About the Company

  • Primary Business Retailer
  • Secondary Business Type Manufacturer / Exporters / Wholesale Suppliers

Opening Hours

  • SUN : Closed
  • MON : 9:30 AM - 6:30 PM
  • TUE : 9:30 AM - 6:30 PM
  • WED : 9:30 AM - 6:30 PM
  • THU : 9:30 AM - 6:30 PM
  • FRI : 9:30 AM - 6:30 PM
  • SAT : 9:30 AM - 6:30 PM
Introduction:
Medilife Technologies provides innovative and quality medical products in Audiology and ENT. It is a 13 years young and includes our group companies in the field of ENT, Audiology, Neonatology, Neurology, Radiology and Psychiatry. The first group company was started in 1987 and pioneered many medical innovations in both manufacturing in India or bringing these technologies to India. Medilife has partnered with reputed manufacturers based in Germany, Japan, Brazil, Russia, Italy etc.
Medilife Technologies has been established by promoters who are well experienced in the field of Medical and Services application. The company is run by a team of professionals with cumulative 80 years of experience in the medical industry, with offices/representatives in Delhi, Mumbai, Lucknow, Kolkata, Bangalore etc.
Our Mission:
• To effectively contribute in healthcare by providing quality medical equipment to improve people’s lives.
• To give support to Medical Professionals by providing not only quality equipment, but also working together to achieve optimal outcomes.
• To help improve the quality of life of people through innovative and quality solutions, to help patients live longer, better happier and healthier lives..
Our Customers:
At Medilife Technologies we cater to the needs from individuals and smallest of the clinics to the largest of the corporate hospitals and centers providing customized and effective solutions. We have completed over 12000 installations in the field of ENT, Audiology, Neonatology, Neurology and Psychiatry.
Our Few Major Customers:
• All India Institute of Medical Sciences (Delhi, Jodhpur, Raipur, Bhopal, Rishikesh, Patna, Bhubaneswar)
• All India Institute of Medical Sciences (Delhi, Bhubaneswar)
• All India Institute of Speech & Hearing, Mysore
• S.R. Chandrasekhar Institute of Speech & Hearing, Bangalore
• Madras Audiology & Speech Therapy Centre, Chennai
• Kasturba Medical College, Mangalore
• Post Graduate Institute of Medical Education & Research, Chandigarh
• Government Medical College Hospital, Chandigarh
• Dr. Wachasundar,Pune
• Safdarjang Hospital, New Delhi
• Himalayan Institute Hospital, Uttarakhand
• Mr. Salaj Bhatnagar, Indore
• Dr. Rajendra Prasad Govt. Medical College, Kangra, H.P.
• SRMS Institute of Medical Sciences, Uttar Pradesh
• Geetanjali Medical College & Hospital, Udaipur
• Dr. Gaurav Sharma, Udaipur
• ESIC Medical College & PGIMSR, Bangalore
• Microcare ENT Laser center, Kukatpally, Hyderabad
• ESIC Medical College and Hospital, Faridabad
• Uttarpara Speech And Hearing Centre
• Aarupadai Veedu Medical College and Hospital, Pondicherry
• NITTE Institute of Speech & Hearing, Mangalore
• Father Muller Hospital, Mangalore
• SAIL, Bhilai and many more…….
Read More »

Contact Information

Medilife Technologies

  • Medilife Technologies
  • 1st Floor, Vikas Plaza, Plot No-02, Local Shopping Center, Above HDFC Bank, Kalkaji, New Delhi - 110019

Find Popular Dental Diode Laser Dealers in Delhi

top