Transducer Protector
Usage :It’s a membrane filter which is used to prevent the bloodfrom entering the tubing leading to the transducer in hemodialysis, ensuring accurate reading.Features & Specifications :Hydrophobic membrane with 0.2 micron pore size.Prevents contamination of the internal pressure monitoring lines.Ridged finger grip around the outside for better grip.Fast Response.Antibacterial hydrophobic air filter with female luer lock/male luer lockColored housings available for identificationHousings designed to withstand pneumatic pulsing ApplicationConnects blood tubing with dialysis machine.Protective hydrophobic barrier allows only sterile air to pass through, protecting patients and equipment from cross contaminationPrevents blood and dialyzing fluid from damaging sensitive transducer monitoring devicesSterile, Non-Pyrogenic.
...moreRenal Dialysis Kit
Features & Analysis – Saves time & buying cost, reduces the risk of infection to. It is made up of top-grade contents. Infection control-infection prevention is one of prime importance among healthcare providers and patients, disposable sterile dressing kits help to prevent HAI (hospital Acquired Infection). Cost effective-from procurement to sterilization, our one-site purchase system provides you complete supply chain, give you most cost effective choice Easy storage-the all-in-one and ready-to-use sterile dressing kits are suitable for many healthcare settings, components are sequentially packaged, compact packaging is easy to store and deliver. Kit of Renal Dialysis Pack Includes ( on & off system) Therapeutic towel Waste storage bag Pallet plastic Examination gloves 1 pair Iodine gauze Alcohol cotton ball Gauze pad X 2 pieces Adhesive tape non woven size 10.5 cm X 7.5 cm Wound dressing pad Size 7 cm X 6 cm non woven Syringe 10 ml X 2 Pcs
...moreNeedle Free Connector
Features –Designed to protect your patients’ catheters from contamination and increased risk of catheter-related bloodstream infections during hemodialysisand aphaeresis applications.Advantages –• Closed system improves outcomes by helping reduce CRBSIs.• Saline flush can help reduce the use of heparin.• May help lower overall costs.Functional Advantages-• Straight fluid path accommodates flow rates of greater than 600 ml/min.• Remains in place during the entire hemodialysis or apheresis treatment period.• Validated for continuous patient use for up to seven days.• Silicone seal remains closed when not activated, closing the fluid path and eliminating blood exposure.Available in Single Lumen to Five Lumen
...moreMeasured Volume Fluid Administration Set
Features :Transparent, soft, cylindrical & calibrated measured volume chamber with bold marking scaleBacteria retentive air inletInjection port for intermittent medicationAutomatic shut off valve prevents air trapping in the fluid line once the measured volume chamber is empty, and it also indicates the level of liquid 15 μm fluid filter to reduce particulate matterApproximately 60 drops/ml , Soft and kink resistant PVC tubingStandard tube length : 150 cm, Available in size: 100 ml, 110 ml, 150 ml Product SpecificationsBurrete in 100ml, 150ml and 200ml available(with end without Auto-Shut off Float Valve)Injection site (Y-site, flashbulb or rubber tube)Transparent Hub – Soft Clear Flexible Tubing23 G Vein Needle – Sterile Pack – ETO sterilization
...moreintravenous set
Intravenous Set with / Without – Air vent Sharp and easy piercing air vented spike Bacteria retentive air inlet with snap on cap / Filter Option Transparent drip chamber Approximately 20 drops/ml Product Feature and Specifications compliant drip chamber (15, 19 drop/ml)V-Clamp compliant end-connectionInjection site (Y-site, flashbulb or rubber tube)Transparent HubSoft Clear Flexible Tubing21 Vein Needle (Optional)Sterile Pack – ETO (Ethylene Oxide) Sterilization.
...moreIntravenous Cannula
Features: Injection valve provides an easy inlet for intermittent medication One way silicone valve allows medication preventing back flow protection cap over the injection valve minimize bacteria movement Wings for fixing the catheter as per body contour at venipuncture site Imported Silicone tipped needle for ease of penetration and trauma Transparent flashback chamber for quick visualization of blood Radiopaque line for correct placement Disposable, sterile and non-pyrogenic Sizes : 14 G to 22 G with / With out and with Injection Port Protocol for Size Selection: 16 Gauge: This size is mostly used in the ICU or surgery areas. This large size enables many procedures such as blood administration, rapid fluid administration, etc. 18 Gauge: Commonly used for administering blood, pushing fluids rapidly, etc. Can be use forCT / PE Protocols or other testing that requires large IV sizes. 20 Gauge: You may be able to push blood* through this size if you can’t use an 18 gauge, but always check your protocol. This size is better for patients with smaller veins. 22 Gauge: This small size is good for when patient’s aren’t critically ill and for short stay. You usually can’t administer blood* due to it’s small size, however, some hospital protocols allow for 22 G usage if necessary. For Neonates and Paediatrics we also manufacture 24 G and 26 G 24 Gauge: This size is used for pediatrics and is usually only used as a last resort as an IV in the adult population
...moreInsulin syringe
Insulin Syringe fitted with Ultra Thin Japanese Needle, so less traumatic, Easy handling due to design and automatic assembly process, zero (Min) dead space so no valuable medication wastage Features The needle is short and thin and covered with a fine layer of silicone to allow it to pass through the skin easily and lessen pain. A cap covers and protects the needle before it is used. The barrel is the long, thin chamber that holds the insulin. The barrel have measurement markings for medication filling. The plunger is a long, thin rod that fits snugly inside the barrel of the syringe. It easily slides up and down to either draw the insulin into the barrel or push the insulin out of the barrel through the needle. The plunger has a rubber seal at the lower end to prevent leakage. The rubber seal is matched with the line on the barrel to measure the correct amount of insulin. A 0.25 m or 0.33 ml syringe usually is best for children (who often need very small doses of insulin) and for people with poor eyesight. 1 ml syringe may be best for an adult who needs to take a large amount of insulin. Also available in needle sizes of 29 G/30 G/ 31 G with Needle length 6 mm / 8 mm / 12 mm and in Unit 40 Markings ( u-40) and Unit 100 Marking (U – 100)
...moreFoleys Catheter
Features: Material– Natural Rubber, Latex with Silicone CoatingColor-YellowTypes:Straight-single use catheters Have a single lumen with a small 1¼ cm opening2-way Foley catheters (retention catheters)- With an inflatable balloon that encircles the tip near the lumenCurved or Coude -Catheters have a rounded curved tip (elbowed) used in older male patients with enlarged prostates which partially obstruct the urethra3-way Foley catheter – Often called retention catheter, they have 2 or 3 lumens that encircle the body of the catheter.One lumen – Drains the urine through the catheter into a collection bag.Two lumen – Holds the sterile water when the catheter is inflated and is also used to deflate the balloon.Third lumen – May be used to instill medications into the bladder or provide a route for continuous bladder irrigation. Designed to ensure that the balloon material, tips and fluid channel provide the best possible Available Sizes and Diameters: 5 Fr, 6 fr, 8 fr 10 fr, 12 fr, 14 Fr, 16 Fr, 18 Fr, 20 Fr, 22 Fr, 24 fr, 26 fr.Note – 3 Fr. = 1 mm (i.e. 24 Fr. catheter equals to 8 mm in diameter)
Material : Natural Rubber, Latex with Silicone Coating
Color : Yellow
...moreFistula Needle
Ultra wall and siliconized fistula needle with or without back eye. Unique process on blade to reduce pain and skin damage occurred at the time of puncture Flexible fixed or rotating wing for easy slip-free puncture operation & for proper fixation and Identification of Needle Soft, frosted PVC tubing Clear kink resistant tube fitted with female Luer lock & pinch clamp Needle Protector to care Para Medical Staff from Needle stick Injury also available Sizes Tube length: 30 cm Needle Gauge available: 15 G, 16 G, 17G
...moreDouble Lumen Catheter Kit
Soft kink resistance, translucent tubing made from medical grade PVC. The double drip clearly visible chamber facilitates visual access and raped adjustment of fluid level. Specially designed roller (thumb) controller offer accurate regulation of infusion rate. Self sealing bulb latex for extra medication to avoid any contamination and easy flushing. Specifications; Tube Length: 1500 mm – O.D. 4.2 mm x I.D. 3.0 mm Needle: 18 G x 1.15” for smoother flow. Blood drop size of 20 dropsml (D.W.) Chamber filter: 200 x 4 sq.cm
...moreCentral Venous Catheter
Our Main Features • Central Venous Catheter reduces risk and vascular trauma due it specially formulated andbiocompatible Polyurethane (PU) material provides strength during insertion and also softens at body temperature to conform to the body tissues• Soft Flexible / Standard St. / J-Tip Guide Wire to provides better manuverability to confirm smooth insertion• Specially designed soft & beveled tip for smooth & easy insertion of catheter• Clear and definite marking facilitates better placement of catheter tip to avoid Puumothorax• Radio-opaque Catheter, with Strainght Needle / Y Needle ( extra port for conformity of vein by using syringe)• Sterile product for single use• Individually tray packed• Central Venous Catheter Kits are available in Single Lumen, Double Lumen and Triple Lumen and four lumen upon request
...moreBlood Transfusion Set
Features:The soft kink resistance, translucent tubing, prepared from medical treated PVC material. The double drip clearly visible chamber facilitates visual access & raped adjustment of fluid level. Specially designed roller (thumb) controller offer accurate regulation of infusion rate. Self sealing bulb latex for extra medication to avoid any contamination and easy flushing. SpecificationsTube Length: 1500 mm – O.D. 4.2 mm x I.D. 3.0 mNeedle: 18 G x 1.1/5” for smoother flow.Blood drop size of 20 drops/ml (D.W.)Chamber filter: 200 x 4 sq cm Operational length – 1490 mm. Flow of 20 drops (1.0 ml of the distilled water flow) Filter size of 175 µm. Water repellent air filter is 1 µm. Smooth adjustment of transfusion speed. Luer injection needle with a diameter of 0.8 or 1.2 mm (under the customer’s order). Sterile, pyrogen-free, non-toxic, anti allergenic.
...moreBlood Line for Dialysis
Blood Line for Haemodialysis usage : Unique chambers -Reduce foaming, increase air removal & do not trap compliant transfer material due to Transducer Protector, Blood Line Sets is manufactured in many configurations and specifications to meet user’s needs and to fit all types of dialyzers and dialysis equipment’s. Mediways is strict on control over each manufacturing step, from plastic formulation to final sterility assurance, ensures that our Blood Line Sets are of the highest quals Manufactured with Medical grade PVC tubing Guarded access ports reduce infection risks. All parts are of superior quality, unique design and high performance. Male/Female lure locks are in compliance with the related international specifications. 100% test for each blood line sets Components Features: Color coded – Ergonomic clamps, Makes tight seal for disposal Specially designed luer taper – Fits all fistula needles female hubs ,shunts, & sub-clavian catheter connectionsColour Coding – Color-coding for Arterial (Red) & Venous (Blue) for quick identificationHighly transparent and flexible tube – To reduce and see through for clotting and air bubbles movementPump connectors – Designed to provide continuous laminar flow, which reduces the risk for HemodialysisMultiple design – Options Device can be applicable for all different dialysis machines.
Color : rgonomic clamps, Makes tight seal for disposal
...morea v fistula needle
A V Fistula Needle Made by Needle assembly machine so as to confirm no damage to the tip of the needle during the assembly process.and is available with Fixed and Rotating wings to adopt patient body contour of puncture site. Features Ultra wall and siliconized fistula needle with or without back eye. Unique process on blade to reduce pain and skin damage occurred at the time of puncture Flexible fixed or rotating wing for easy slip-free puncture operation & for proper fixation and Identification of Needle Soft, frosted PVC tubing Clear kink resistant tube fitted with female Luer lock & pinch clamp Needle Protector to care Para Medical Staff from Needle stick Injury also available Sizes Tube length: 30 cm Needle Gauge available: 15 G, 16 G, 17G
...more3 Way Stopcock Cannula
3 Way Stop Cock Usage with intra-arterial and intra-venous systems. A red stud is placed on the device if used for arterial purposes (for blood sampling). It provides 3-way flow (from inlet to outlet, inlet to side-port or side port to outlet) by use of the handle on the top of the stopcock to open and close lines. The device can also be used to reduce to lines down to one, for drugs/drug infusion purposes and for the attachment of extension lines. A blood sample can also be taken via the injection port Features : Pressure Limit up to 4.5 bar (65 psi) knob 360 rotation, for better opening of aperture Rotating male luer & two female luer connectors Crystal clear transparent channel Min. priming volume required for accurate drug administration Leak proof body withstands pressure up-to ten bars when applied in normal conditions Lipid Resistant body also available for Oncology and Cardiac care specially 3 Way with Extension also available from 10 cm to 200 cm
...moreBe first to Rate
Rate ThisOpening Hours