Melt Flow Index Apparatus
Get Price Quote
Melt Fow of Thermoplastic material is defined as the rate of flow in grams per ten minutes of extrudate of molten resins through a jet of a specified length and diameter under prescribed conditions of temperature, load & piston position in a cylindrical cavity inside a heated metallic tube barrel at the measurement is being made.The extruder tube assembly is mounted on a metal box. A sheet metal control panel is mounted on the side of the equipment & houses the pid controller, digital preset timer at other electronic components. Cleaning tools for tube cavity and jets & stoppers & cutter for the extrudate are also supplied with the equipments.
Melt Flow Index Tester
45,000 - 150,000 Per Piece
1 Piece (MOQ)
Best Deals from Melt Flow Index Tester
Melt Flow Index Apparatus
Get Price Quote
We provide high performance Melt Flow Index Apparatus that is used to test the rate of extrusion of resins through a die. We have carved a niche as one of the overruling Melt Flow Index Tester Suppliers based in India. Robust construction, accurate results and easy operation are some of the salient features of our Melt Flow Index Test Equipment.
Melt Flow Index Apparatus
48,000 Per Piece
Features: Metal body Crack resistance Easy and handy Light weighted High strength Polished surface Details : ESPM GS IEC IAS
Melt Flow Index Apparatus
Get Price Quote
Product Code: EKE 902Melt Flow Index Apparatus is used for determination of the Melt Flow Index of Polythene compounds. It is suitable for operation on 220 V, 50 Hz, Single phase, AC supply. The apparatus consists of a metallic cylinder, fitted with heating elements and enclosed in a metallic chamber. A piston and two weights are provided to facilitate the measurement of the flow index property. An automatic thermal control unit provided helps to regulate the uniform and slow heating of the sample.Details Standrad: IS : 1596, IS:2530 EKE 90201 Bent Type Thermometer, Range: 160º C to 200º C EKE 90202 Heating Element EKE 90203 Spare Jet
Melt Flow Index Tester
Get Price Quote
1 Piece(s) (MOQ)
As a reliable name, we ensure that payment procedures remain secured with us. For this, we issue invoice to the customers stating the products, quantities and agreed prices. The material required for preparing quality-centralized product range is sourced from the trusted places and that too after complete quality confirmation.
Melt Flow Indexer
Get Price Quote
MYQ Melt Flow Indexer, often abbreviated as "MFI", is an affordable-price tabletop instrument used to test the melt flow resistance (MFR) of a wide range of thermo-plastic materials. The tester conforms to all National and International melt flow resistance standards, including BS EN ISO 1133 and ASTM D1238. Any temperature within 120°C-450°C (248°F-842°F) can be accurately controlled.Included weights 1 600g 1 875g 1 960g 1 1000g 1 1200g 1 1640g 8 2000g Features Built-in microprocessor maintains temperature control to within ±0.2ºC (±0.4ºF), with rapid ramp-up to set point. Temperature fluctuation is ±1% of set temperature. Extruded material automatically cut-off by built-in scraper mechanism at preset intervals, controllable to ±0.01 seconds. Clear multi-line LCD display and tactile-feedback membrane keypad allow fast, accurate input of test parameters and provide continuous display of settings during testing. AccessoriesThe Melt Flow Indexer is supplied with all the accessories and weights necessary for maintenance and operation. Nothing else to buy! 2 Piston Rods 2 Tungsten Carbide Dies 3 Replacement Cut-Off Knives 1 Cleaning Tool 1 Charging Tool Die Ejector 1 Level Meter 1 Guide Bushing 1 Filling Funnel 2 Cylinders 1 Die Cleaning Tool
Melt Flow Index Tester
44,000 - 48,000 Per Piece
1 Piece (MOQ)
Melt Flow Index Apparatus
Get Price Quote
Weights (inclusive of weight of the piston)-325 g, 1050 g, 2160 g, 5000g, and 10000 gDiameter of extruder cavity-9.55 mm Dimensions of extrusion hole-2.095 mm x 8.00 mm longTemperature range-Ambient to 400C + 0.1 0C Dimensions of piston head-9.47 mm diameter x 6.35 mm longThe heater logged with mineral wool insulation. The assembly is fixed on a rigid stand. The bottom of the tube is lagged with a 3 mm thick insulation of PTFE to prevent sticking of A PID controller is provided to indicate & control the temperature of the tube. The tube has a hole parallel to its bore for placing the thermocouple junction.In Melt Flow Index Apparatus the extruder tube is made from carbon steel and is heated by means of a Bend Heater, which surrounds its outer circumference. Specifications In Melt Flow Index Apparatus the extruder tube is made from carbon steel and is heated by means of a Bend Heater, which surrounds its outer circumference. A PID controller is provided to indicate & control the temperature of the tube. The tube has a hole parallel to its bore for placing the thermocouple junction. The heater logged with mineral wool insulation. The assembly is fixed on a rigid stand. The bottom of the tube is lagged with a 3 mm thick insulation of PTFE to prevent sticking of Temperature range-Ambient to 400C + 0.1 0C Dimensions of piston head-9.47 mm diameter x 6.35 mm long Diameter of extruder cavity-9.55 mm Dimensions of extrusion hole-2.095 mm x 8.00 mm long Weights (inclusive of weight of the piston)-325 g, 1050 g, 2160 g, 5000g, and 10000 g
Teleflex Meltflow Tester
107,000 Per Units
Melt Flow Index Apparatus
Get Price Quote
Product Code: EKE 902 Standrad: IS:1596, IS:2530 EKE 90201 Bent Type Thermometer, Range: 160º C to 200º CEKE 90202 Heating ElementEKE 90203 Spare Jet Melt Flow Index Apparatus is used for determination of the Melt Flow Index of Polythene compounds. It is suitable for operation on 220 V, 50 Hz, Single phase, AC supply.The apparatus consists of a metallic cylinder, fitted with heating elements and enclosed in a metallic chamber. A piston and two weights are provided to facilitate the measurement of the flow index property. An automatic thermal control unit provided helps to regulate the uniform and slow heating of the sample.
Melt Flow Indexer
Get Price Quote
Melt flow index apparatus for plastic measures the melt flow index of plastic material. The system consists of a heated extruder tube, an interchangeable jet through which the material under test is extruded, and a piston with dead weights to apply the specified pressure on the material inside the extruder tube. The extruder tube is made from carbon steel and is heated by means of a bend heater, which surrounds its outer circumference. A pid controller is provided to indicate & control the temperature of the tube. The heater logged with mineral wool insulation. The assembly is fixed on a rigid stand. The bottom of the tube is lagged with a insulation of ptfe to prevent sticking of the extrudate. The jet through with the extruder is pushed out is made from hardened and ground die steel. It is held at the bottom of the extruder tube. the piston made from silver steel relieved at the upper end is provided to push the extrudate out of the jet. The piston moves inside the cavity of tube. A sleeve to provide to guide the relieved portion of the piston. The top of the piston carries a plate-form for keeping the load on. The plate-form is thermally insulated from the load. the extruder tube assembly is mounted on a metal box. A sheet metal control panel is mounted on the side of the equipment & houses the pid controller, digital preset timer & other electronic components. Cleaning tools for tube cavity and jets & stoppers & cutter for the extrudate are also supplied with the equipments.
Melt Flow Index Apparatus
Get Price Quote
Melt Flow Index measures the rate of extrusion of molten resins, through a die of specified length and diameter, under prescribed conditions of temperature, load, and piston position in the barrel, as the timed measurement is being made.
Melt Flow Index Tester
Get Price Quote
Shear Fatigue Tester, Universal Computerized Testing Machine
Melt Flow Index Apparatus
Get Price Quote
Melt Flow Index Apparatus, Small Jaw Crusher
Melt Flow Index Apparatus
Get Price Quote
Melt Flow Index Apparatus, Humidifier, Dehumidifier