water analysis kit
Water Analysis KIt NPC 363D: Micro controller based.Display: 16x2 BLCD. Measuring Parameter: 8[pH: 0 to 14 pH,mV: 0 to 1999mV,Conductivity: 0 to 1000mS/cm,TDS: 0 to 1000ppt,Salinity: 0 to 50ppt, DO: 0 to 20ppm,Turbidity: 0 to 1000NTU in 2 ranges,Temperature: -200 to + 200 deg C]. Calibration: Auto& Manual .Temperature Compensation: Auto & Manual.Data Storage: 1000 samples.Digital output: Serial RS 232,Parallel Centronics.Mains 23VAC/ 12V Rechargeable battery.Inbuilt ABS briefcase.
...moreUV-VIS Spectrophotometer
Spectral wavelength range: 195 to 1000 nm. Spectral band width: 2 nm. Accuracy: ± 0.5 nm. Repeatability: ± 0.3 nm, Resolution: 0.1nm% T :0 to 100% Abs.:0 to 1.999Conc. : 0 to 1999, K Factor : 0 to 1999, Accuracy: ± 0.005 Abs at 1.0 Abs, ± 0.010 Abs at 1.5 Abs, Stray Light: Less than 0.1%at 320 nm, Readability: ± 1 count, Data Readout: Single Line LCD Display. Key Board: 4 Keys, soft touch membrane type. Printer Interface: Printer Interface for any centronics Dot Matrix Printer , Serial Interface: RS 232C interface, Light Source (a)Tungsten Halogen Lamp (b) Deuterium Lamp (D2), Detector: Wide range silicon Photodiode. Optics: Complete mirror optics with resolution 1200 grooves / mm grating, Sample Holder: 4 Position adjustable sample holder, Power:230 V ± 10% 50 Hz AC ,Dimensions: 420 x 350 x 240mm (LXBXH) Approx., Weight:10 Kg. (Approx.) Accessories: Quartz Cuvete(2), Glass Cuvete(4), Dust Cover, CD(1), Interface cable(1), manual(1).
...moreUrine Analyzer
FEATURES • Friendly software makes it easy to operate • Automatic priming and maintenance minimize problems • Automatic probe cleaning, reducing carry-over • Automatic standby mode makes it ready to work immediately at any time Automatic calibration • Long-life and stable electrodes • TECHNICAL SPECIFICATIONS Parameter: EA-2 : K+ Na+ , EA-3 : K+ Na+ Cl- , EA-5 : K+, Na+, Cl- , Ca2+,PH Assay Method: Ion selective electrode Throughput: 60 samples/ hr Data Storage: More than 2000 samples and Q.C. data Sample Type: Whole blood, serum, plasma or urine Sample Volume: 20 ul Display: 28 mm*64mm back-illuminated LCD Printer: Built-in thermal printer, 58 mm width paper Output: RS-232 Environment requirements: Temperature:18-35°C, humidity:≤85% Power Supply: AC 110V 60HZ, 50W / 220V 50HZ Dimension: 30cm*25cm*24cm Weight: 7.0kg
Weight : 7.0kg
Dimension : 30cm*25cm*24cm
...moreTURBIDITY METER
Digital Turbidity Meter NTM 901: Microcontroller based.Diplay: 16x2 BLCD.Measuring Parameter 2[ Turbidity & temperature].Measuring Range: Turbidity( 0 to 1000 NTU/ JTU in 2 ranges& temperature( -200 to + 200 deg C)].Accuracy; 2%,resolution: 0.1 NTU in lowest range. Calibration: Manual& auto.Digital output: serial RS 232 & Parallel Centronics.Data Entry: By soft touch key with audible sound.Mains 230V AC.Print format: All data date wise.
...moreTds Meter
Digital conductivity meter NDC 736: Diplay: LED.Measuring Parameter 2[ conductivity: 10 umho to 1000mmho in 5 ranges& TDS: 10ppm to 1000ppt in 5 ranges].Calibration: Manual.Temperature Compensation: manual& auto.Mains: 230V AC. Cell constant ccompensation: Adjustable( 0.5 to 1.5).Complete with standard accessories.
...moresyringe destroyer
It is a compact and rugged destroyer and has special steel alloy cutter for safe and quick disposable of NeedleSyringe. It has powder coated, housing with built in removable BIN for burnt needle stubs & cut syringe nozzles. Operations: Two Slot Needle – Electric Burning, Syringe Cutting, Needle Range:14G–30G and 12 mm – 40 mm, (0.5” to 1.5”) long, Cutting Blade :Hardened Steel Alloy, Power Supply: 220 V±10%, 50 Hz AC, Overload Protection: Built infuse, Bin Size : 87 x 78 x 85 mm, Dimensions:220 x 180 x 150mm, Weight : 3 Kg. Approx. Net
...moreStudent Microscope
With triple revolving nosepiece, tube length 160mm with coarse and fine knobs, fitted with fixed condenser N.A.1.2, with iris diaphragm, filter holder and stopper for slide safety .all parts are made of aluminium die-casting and oven painted .Packed in Thermocol packing with vinyl cover, duster, cleaning brush and operating manual.Ach. Objective : 10xand 40xHuy ,Eyepieces : WF10xandH15xMagnification : 100xto600x
...moreSpectrophotometer
Digital Spectrophotometer NSP 365: display: Dual LED Display.Measuring Parameter 3[ Absorbance: 0 to 1999,%Transmission: 0 to 100%,Concentration: 0 to 1999.Detector: silicon photo diode.Grating: 600lines/mm.Light source: Tungsten halogen lamp.Spectral band width: 10mm.Wave length resolution: 1nm. wavelength accuracy: 1nm.Mains: 230VAC.Complete with standard accessories.
...morespectro photometer
Visible spectrophotometer NSP 365 having range 340 to 960nm. Dual LED display for %T, ABS & Concentration. Resolution 1nm.Mains operated.Complete with standard accessories.
...moreSoil Analysis Kit
Digital water & soil analysis kit npc 361d: lcd display for ph,orp,tds,salinity, conductivity.dissolved oxygen & temperature . Main cum battery operation with inbuilt abs briefcase.complete with standard accessories.
...moreSingle Beam Uv Vis Spectrophotometer
Advance Microprocessor UV VIS Spectrophotometer Single Beam NSP - 370 Technical Specifications: Optical System : Single beam, grating 1200 lines/mm Wavelength range: 190 to 1000 nm. Band width: 2 nm. Wavelength Accuracy: ± 1nm. Wavelength Repeatability: ± 0.5 nm, Wavelength Setting : Auto Photometric Accuracy : ± 0.5%T Photometric Repeatability : ± 0.3%T Photometric Range : -0.3-3A, 0-200%T Stray Light : ≤0.3%T Stability : ± 0.002A/h@500nm Display : 128*64Dots LCD Detector : Silicon Photodiode Standard Cell Holder : 4-position 10mm cell charger Light Source Tungsten & Deuterium Lamp Output : USB port & Parallel Port (Printer) Power Requirements :AC 85~250V Dimensions: 420 x 280 x 180mm (LXBXH) Weight:12 Kg Salient Features : Large LCD Screen (128X64 Doys). Can Display and save 50 groups of data, 5 groups per screen. Data can be restore after a sudden power cut. Auto setting wavelength. Tungsten lamp & deuterium lamp cab be turned on/off individually to extend lifetime. Automatical WL. Calibration and dark current getting.
Wavelength Range : 190 to 1000 nm.
...moreSEMI-AUTOMATIC CLINICAL BIOCHEMISTRY ANALYZER
SEMI-AUTOMATIC CLINICAL BIOCHEMISTRY ANALYZER NBCA 517 ( SA-20) (BELGIUM BRAND) FEATURES: *Testing Principle : End point, kinetic, fixed time, multi-standard, bichromatic, sub-wavelength. * Filter wavelengths :340/405/492/510/546 /578/630nm, 2 more open filter positions, others on request. * 20 incubating positions. * Memory: Large memory to store 200 test programs and 1000 testing results. * Excellent Q. C function, Q.C. chart can be stored, displayed and printed. TECHNICAL SPECIFICATIONS: • Reading Cuvette : Both through cell and direct reading cuvette • Incubating Positions : 20 incubation positions • Photometric System : Light Source: 6V 10W long-life halogen lamp • Filters : 340,405,492,510,546,578,630nm, 2 more open filter positions • Wavelength Accuracy : ±2 nm • Measuring System : Measuring Range: 0.3 -3.0 ABS • Photometric Linearity : ±2% from 0 to 2.000 O.D. • Photometric AccuracY : ±2% from 0 to 2.000 O.D. • Drift : less than 0.005 O.D. Carry Over: ≤1% • Incubator Temp. control : 25°C ,30°C ,37°C, Precision:±0.1°C • Reagent Volume : 200-500 ul • Printer : Built-in thermal printer, 57mm width paper • Power Supply : 110V 60HZ / 220V 50HZ, 60VA • Dimensions : 34cm*38cm*18cm • Weight : 8.5kg
...morepH Meter
1 Piece(s) (MOQ)
We offer ph meter nig 334: micro controller based,lcd display,manual& auto calibration,manual& auto temperature compensation,measuring parameter: ph,temperature and m v .data storage & computer attachment facility, mains operated.
...morePEN TDS EC CONDUCTIVITY METER
SPECIFICATIONS: TDS Meter HI 96301 (DIST® 1) HI 96302 (DIST® 2), Range: 1990 ppm 10000 ppm Resolution: 10 ppm 100 ppm Accuracy ±2% F.S. ±2% F.S.(@20°C/68°F): EC Meter HI 96303(DIST® 3), HI 96304 (DIST® 4) Range: 1990 μs/cm 19900 μS/cm Resolution: 10 μS/cm 100 μS/cm Accuracy ±2% F.S. ±2%F.S.(@20°C/68°F): Calibration: manual, 1 point, through trimmer Temperature Compensation Automatic, 5 to 50°C (41 to 122°F)Battery Type / Life (4) 1.5V / approx. 150 hours of continuous use Environment 0 to 50°C (32 to 122°F); RH max 95%Dimensions:150 x 30 x 21 mm (5.9 x 1.2 x 0.8'')Weight 70 g (2.5 oz.)
...moreNTM DIGITAL TURBIDITY METER
DIGITAL TURBIDITY METER NTM 900 Range: 0 to 1000.0 NTU/JTU. Resolution:1 NTU/JTU.Accuracy: ±3 % (FS) ±1 digit ( 0 to 400JTU) + 4% (FS)+1 digit (401 to 1000JTU).Sample System: 30 mm clear glasstube. Light Source : 6V,1Amp. Tungstenlamp. Detector: Photodiode. Display:31/2 digit LED display. Power Supply:220 V ±10% 50 Hz, AC. Size ( Lx B xH): 275 x 195 x 105 mm. Weight: 5KGs. Accessories: Test Tube Set,Instruction manual. dust Cover etc.
...moreNSD NEEDLE SYRINGE DESTROYER
Technical Specifications It is a compact and rugged destroyer and has special steel alloy cutter for safe and quick disposable of Needle/Syringe. It has powder coated, housing with built in removable BIN for burnt needle stubs & cut syringe nozzles. Operations: Two Slot Needle – Electric Burning, Syringe Cutting, Needle Range:14G–30G and 12 mm – 40 mm, (0.5” to 1.5”) long, Cutting Blade :Hardened Steel Alloy, Power Supply: 220 V±10%, 50 Hz AC, Overload Protection: Built infuse, Bin Size : 87 x 78 x 85 mm, Dimensions:220 x 180 x 150mm, Weight : 3 Kg. Approx. Net
...moreNIG335 MICRO CONTROLLER Meter
MICRO CONTROLLER pH-Cond-TDS-SAL Meter NIG335 Function :pH & temperature OR mV & temp. OR Conductivity & temp. OR TDS & temp. OR Salinity & temp simultaneously Display : 16 character x 2 lines Alphanumeric BL LCD Power supply : 230 V ± 10% 50 Hz AC pH Range : 0 to 14 pH ,Resolution: 0.01 pH, Accuracy : ± 0.01 pH ± 1 digit, Slope adjustment:80% to 120% By default 100%,Temp .compensation: 0 to 100 ˚C Auto with temp probe / Manual with keys .Auto buffer recognition : 4.00 pH, 7.00 pH,9.20 pH, Calibration : Auto & manual, 3 point & 2 point (Programmable) Conductivity-TDS-SAL Range: Conductivity 0.00 uS/cm to 1000 mS in 6- Auto ranges, TDS: 0.00 ppm to 200 ppt in 6- Auto ranges , SAL: 0.0 ppt to 50 ppt Auto ranging, Resolution: Conductivity 0.01/.1/1 u S/ m S as per range, TDS: 0.01/.1/1 ppm/ ppt as per range, SAL: 0.1 ppt, Accuracy : ± 0.5%of range ± 1 digit, TDS Factor : 0.50(By default) & adjustable manually, SAL Factor : 0.75(By default) & adjustable manually, Cell const. adjustment : Digital 0.05 to 2.000 By default 1.000,Temp. compensation : 0 to 70 ˚C Auto with temp. probe/Manual with keys, Temp. Coefficient adj. : 0.00% to 4.00% adjustable. By default 2.00%, Reference Temp. : 20 Degree C & 25 Degree C, Mode of Calibration: By Value & By Measurement Temperature Range: -20.0 ˚C to 200 ˚C Resolution : 0.1 ˚C ,Accuracy : ± 0.1% of range ±1 digit, Calibration : two point manual, Sensors : Pt100 probe, Data entry : By six soft touch keys with audible sound , Storage : 1000 samples, Real time display : 24 Hour ,Print format :All Data & Date Wise (Programmable),Digital output : Serial RS-232 ,Parallel mode with Date ,Interface: RS-232, Centronics & computer Print format :All Data & Date Wise (Programmable),Digital output : Serial RS-232 ,Parallel Centronics (Programmable),Error Indication : pH ERROR,ORP ERROR, CAL ERROR & T-ERROR, Accessories : pH Electrode , Cond /TDS Cell, Temp. Probe, Dust Cover, Instruction Manual.
...moreNIG 334 MICRO CONTROLLER pH METER
MICRO CONTROLLER pH METER NIG 334 COM_DJCATALOG2_CATEGORY: pH Meter Laboratory Instrument MICRO CONTROLLER pH METER NIG 334 Technical Specifications Range: 0 to 14 pH mV ;Range:-1999mV to+ 1999mV ,pH: Resolution: 0.01 pH,mV: Resolution: 1mV, pH: Accuracy: ±0.01 pH ±1 digit, mV: Accuracy : ±0.1% of range, Slope Adjustment: 80% to 120% ±1 digit ,Calibration :mV: 2 point manual, Temp. Compensation: 0-100°C by default 100%, automatic with temperature probe / manual with keys. Auto Buffer Recognition: 4.00 pH, 7.00 pH, 9.20 pH Calibration: 2/3 point auto & manual, Real time display: 24 Hour Temperature: Range : - 50°C to +200°C mode with date, Resolution: 0.1°C Interface: Rs232, Centronics & computer Accuracy:±0.1% +1 digit of range Print format: All Data & Date, wise , Calibration: Two point manual Digital output :Serial RS 232,,Parallel Centronics ,Sensor: Pt100 probe (Programmable), Data Entry: By six soft touch Functions: pH OR mV & keys With audible sound Temp. simultaneously, Storage: 1000 samples Display: 16 Character x 2 lines Alpha numeric Power Supply: 230 V ±10%, 50 Hz AC, Error Indication: ERROR,ORP ERROR, CALERROR & T ERROR, Dimensions: (L x B x H) 235 x 245 x 80 mm, Weight: 3.00 Kgs, Standard Accessories: pH Electrode, Electrode stand, Dust Cover, Instruction manual, Buffer solutions, Temperature probe.
...moreNIG 333 Digital pH Meter
Range: pH: 0 - 14 pH. mV : 0 to ±1999mV, Resolution: pH:0.01pH, mV : 1 mV. Accuracy: pH : ±0.01pH ±1 digit, mV : ±1mV ±1 digit. Slope Correction: 80% to 120% . Temp. Compensation: 0-100°C Manual & (Automatic optional). Indication: 3 ½ digit LED (12.5 mmhigh). Power Supply: 230 V ±10%, 50 Hz AC. Input Resistance: 10^12 ohms. Ambient Temp.: 10° C to 50° C. Dimensions (L x B x H): 210 x 190 x 90 mm. Weight: 3.0 Kgs. Accessories: pH Electrode, Electrode stand, Dust Cover, Instruction manual, buffer solutions.
Weight : 3.0 Kgs
Power Supply : 230 V ±10%, 50 Hz AC
...moreNeedle Syringe Destroyer
Needle syringe destroyer:It is a compact and rugged destroyer and has special steel alloy cutter for safe and quick disposable of Needle/Syringe. It has powder coated, housing with built in removable BIN for burnt needle stubs & cut syringe nozzles. Operations: Two Slot Needle – Electric Burning, Syringe Cutting, Needle Range:14G–30G and 12 mm – 40 mm, (0.5” to 1.5”) long, Cutting Blade :Hardened Steel Alloy, Power Supply: 220 V±10%, 50 Hz AC, Overload Protection: Built infuse, Bin Size : 87 x 78 x 85 mm, Dimensions:220 x 180 x 150mm, Weight : 3 Kg. Approx. Net
...moreNDC 737 MICRO CONTROLLER CONDUCTIVITY METER
TECHNICAL SPECIFICATIONS Conductivity: Range : 0.00 u S/cm to 1000 mS /cm, Auto ranging. Resolution: 0.01uS on the lowest range Accuracy:±0.5% of range ±1 digit. Temp. Compensation : 0-70°C, Auto with temp. probe/ manual with keys. Temp. coefficient adjustment: 0.00% to 4.00% adjustable by default 2.000%. Cell Constant adjustment: Digital 0.05 to 2.000 by default 1.000.Reference Temp. :20°C & 25°C. Measuring Frequency :100Hz and 1 KHz , auto selection. Calibration: Manual. Mode of calibration: By Value & by Measurement. Temperature :Range: -200° C to +200° C. Resolution: 0.1° C. Accuracy: ±0.1% of range ±1 digit. Calibration: Two pointmanual. Sensor: PT-100 probe. Data Entry: By soft touch keys with audible sound. Data storage : 1000 samples. Real time display: 24 Hour mode with Date. Interface: RS-232, Centronics & computer. Print format: All Data, Date Wise. Digital output :Serial RS 232, Parallel Centronics. Functions: Conductivity & Temp. Simultaneously. Display:16 Characters x 2 lines Alphanumeric BLCD. Power Supply: 230 V ±10%, 50 Hz AC. Dimensions: (Lx B x H): 235 x 245 x 80 mm Weight : 3 Kgs. Accessories: Conductivity cell, Dust Cover, Temp. probe, Instruction manual.
Weight : 3 Kgs
...moreNDC 736 DIGITAL CONDUCTIVITY METER
Technical Specifications Range:10 u mho to 1000 mmho In 5 ranges. Resolution: 0.01 umho. Accuracy (F.S): ±0.5% ±1 digit. Cell ConstantCompensation: Adjustable. Display: 3 1/2 digit LED. Input Frequency: 1000 Hz, Temp Comp.:Manual & Automatic(optional). Dimensions (L x B x H): 210 x 190 x90 mm. Power Supply : 230 V ±10% 50 Hz AC. Ambient Temp.: 10° C to 50° C. Weight:3.00 Kgs. Accessories: Conductivity cell, KCL solution, Dust cover, Instruction manual.
Range : 10 u mho to 1000 mmho In 5 ranges
Accuracy : ±0.5% ±1 digit
Weight : 3.00 Kgs.
...moreNBCA FULLY AUTOMATIC BIOCHEMISTRY ANALYZER
FEATURES: • Batch Analyzer • End point, kinetic, fixed time, bichromatic, serum blank, 1-2 reagent assays, multi-standard and all users programmable • Insert sample at any time during testing • With liquid sensor and automatic probe washing avoiding carrying over • Automatic carry-over control function (patented) • Reaction tray reusable • QC data with levey-jennings chart • External printer, multi printing forms are available • Intelligent multi task software • Complete open parameters setup makes the analyzer may work with any kits qualified locally TECHNICAL SPECIFICATIONS: • Reagent Capacity: 20 refrigerated reagent positions • Throughput: 20 tests /hr • Reading Cuvette: Flow through cell • Temperature Precision: 37°C ± 0.1 • Program Memory: Store 200 test programs and more than one million test results • Calibrator : 1-6 standards • Sample Capacity: 64 for sample, calibrator/standard and control • Optical system: Light Source: 6V/10W long-life halogen lamp Filter: 7 high quality narrow band filters and 2 more open filter positions • Wavelength Range: 340nm-750nm • Photometric Measuring Range: 0-3.0 O.D • Diluter: 1000ul, 1.0ul/step • Reaction Tray: 96 reaction cuvettes placed in temperature controlled incubator • External Devices: Pentium IV PC, printer. • Power Supply: 110V 60HZ / 220V 50HZ • Software: Windows XP/2000 • Weight: 71kg
...moreMICRPROCESSR LAB ANALYSER
Technical Specifications Display:16x2 Lines Alfa Numeric Display ,Display Mode : %T, ABS and 3 Concentrations Mode I .e. C1,C2,C3.The Instrument can measure ABS, %T, Concentration for all End Point Chemistries. No Need of calculations. Zero Adjustment : Automatic(Without knob Rotation ) Wave length Range:400 to 700nm.[ 8 standard Glass Filters]Peak wavelengths:400 , 430, 480 , 500 , 520 , 540, 630, 670nm .Accuracy: + 0.02 O.D Sensitivity: + 0.02 O.D. Per Hour. Light Source :6.8 V,0.3 A. Tungsten Lamp. Amplifier: Micro controller based Inbuilt memory retain 3 Concentration and Last “K” Factor for Concentration even after power loss. Detector: Silicon Photo diode, Sample Volume :1 ml. Data Entry: By six Soft Touch Keys. Power supply: 230V+ 10%,50 HZ AC. Dimensions : 340X315X175 mm..Weight:2 Kgs approx. Accessories :Glass Test Tubes (5), Spare Lamp ( 1) ,Manual, Dust Cover etc.
Weight : 2 Kgs
...moreBe first to Rate
Rate ThisOpening Hours