Slit Lamp
Microscope
The operating microscope improves visualisation of the anatomy present leading to better outcomes for the patient. The surgical microscopes from opthomax are exactly made to the requirements of microsurgery. A compact optical unit delivers clear and sharply focused images and the modular system gives the surgeon optimum mobility. Microscope Specifications : Binocular optical head with coaxial illumination only head imported. Eye piece: wide field 10x or 12.5x individually adjustable Inclined binocular tube 45′. Diopter adjustment of +5.00 to -5.00 Interplanetary adjustment 55mm to 75mm Objective lens 0.5 diopter (175±25mm) Working distance 150mm Total magnification: 3.4to20x Zooming ratio:1:6:5 Field of vision: 40mm to 60mm at the minimum magnification Fine Focusing motorized with foot control. Also available with shin nippon head and indian stand.
...moreMatrix autoref-keratometer premio
Matrix autoref-keratometer premio R10 & KR10 We offer Matrix autoref-keratometer premio compact elegant & light weight with auto read function to measure automatically both refractive error as well as keratometry readings when alignment meets be measurement requirements. Salient Features Tilt-able Large colour LCD (7 inch) with touch screen interface, motorized chinrest & auto- racking helps an user to use single handedly. Reliable easy load fast thermal Printer with Auto Cutter, avoids printing paper jam. Smooth Motorized Chin Rest operation from operator’s side close to joy stick. Easy and elegant looking Flip / Flop temporary locking knob to arrest unwanted movement when not in use. Auto Tracking of Central Cornea with Auto Shot. BMM-3 / BMM-5 (Burst measuring mode of 3 or 5 Readings in one shot). Technical Specifications: Refractive Measuring Range Sph. : ± 25D, CyI. : ± 10D (0.12D or 0.25D step) Axis : 1~180° (1° step) Keratometer Measurement Range Radius of Corneal curvature : 5.0~10 mm (0.01 mm step) Corneal Refraction : 33.00D ~ 67.00D (0.12D/0.25D step) Corneal Astigmatism : 0 ~15.00D (0.12D/0.25D step)/Axis : 1~180 Measurement Mode Automatic or Manual (Selectable from Screen) Mode of Operation REF mode/K-mode or R/K mode (selectable) Vertex Distance 0.12, 13.5 or 15mm (selectable) Min.Measurable Pupil Diameter Ø 2.00 mm Measurable Pupillary Distance (PD) 30~85mm (1mn step), Automatic Measurable Cornea, IPIS & Pupil Size 2.00mm~12.00mm, by adjusting the cursor on the image Fixation Target Scientifically designed auto-fogged scenic picture Printer Fast Thermal Printer with easy paper load facility Internal Monitor 5.7 inch hi-resolution color LCD monitor Shifting Range Back & Forth : ±19mm ; right & left : ±44mm UP/DN : ±19 mm ; Chin rest : ±30mm Power Saving Function OFF, 5min or 15 min (selectable) Data Transmission RS-232 interface (For Auto Phoropter) Power Source / Consumption 110~240. AC 50~60 Hz / 60 VA W 288(W) x 500 (D) x 480 (H) mm / 14 Kg Quality Certification CE & ISO 9001 : 2000
...morechair unit
Chair Unit Specifications :- Our chair-unit is Need-based, highly economical combination unit. Maximum operative functionality; minimum space consumption. Comprehensive, easy-to-use console panel control with memo key.165-degree reclining, gas spring-driven chair. Smooth, CE-marked German DC motor-driven elevation. Sliding table with space for two instruments. Holder for hand instruments. Dust-free, enclosed Trial Lens Rack with straight, unobtrusive, in & out sliding movement. Sturdy Lamp Pole to support multi-instrument mounting. Cross-integrated Chair Raising System & Sliding table Top. Comfortable Polyurethane seat. Moulded plastic-covered base area.Broad, square format platform for stable mounting &jerk-free performance
...moreB-scan ultrasonography
B-scan ultrasonography is used to provide cross-sectional two-dimensional images of the inner eye. Ultrasound is helpful for diagnosing retinal detachment, vitreous bleeding, tumors, inflammation, lesions in the eye socket bone, or foreign bodies in the eye. Features:- 8 Pseudo-color Mode High Resolution Images Imaging Mode: B, B+A, B+B, A Memory: up to 8 Images Zoom: from 34 ~ 60mm, 6 steps adjustable Variable Displaying Area 5 Segments Adjustable TGC Cineloop for 5.6sec Accurate Axial Measurement under B-mode (SMI-5) Manual Correction of Axial Measurement under A-mode (SMI-5) Multi-groups of Calipers for Distance Measurement Various Area Measurement Method Measuring Mode: Contact and Immersion Save up to 50 Groups of IOL Calculation Results 8 Groups’ Average with Standard Deviation (S.D.) High Resolution Large Screen LCD Monitor B-Probe Protection: Hibernation after 10 minutes of Continuous Scanning Trackball for Easy Measurement and Operation Real-time Clock Optional Image Output: Video Printer or Workstation specifications:- B-SCAN Probe Frequency: 10MHz Scanning Angle: 53° Resolution: axial≤0.2mm, lateral≤ 0.4mm Zoom: 34mm ~ 60mm, 6 steps adjustable TGC: -30dB ~ 0dB dynamic, 6 points manually adjustable Dynamic Replay for 5.6 sec, 56 images displayed continuously or separately Variable Delay Depth: 0 ~ 15 mm Multi-groups of Electronic Calipers for Distance Measurement Various Area Measurement Methods Post Processing: 4 groups of curves (Liner, Logarithmic, Exponential, S-curve) Total Gain: ≥98dB, adjustable Gray Scale: 256 levels A-SCAN Probe: 10MHz with Fixation Red Light Resolution: 0.01mm Biometry Accuracy: ≤±0.06mm Gain: ≥98dB with an adjustable range of 0 ~ 59dB Measuring Range: 15 ~ 39mm Measuring Parameters: Anterior Chamber Depth, Lens Thickness, Vitreous Length and Axial Length. 5 Different Measuring Modes: Automatic (for Normal, Dense Cataract, Aphakic and Pseudo-aphakic) & Manual 8 Groups’ average with Standard Deviation (S.D.) IOL Formula: SRK/T, SRK-II, BINKHOST-II, HOLLADAY, HOFFER-Q and HAIGIS Save up to 50 groups of IOL calculation results and 4 groups of IOL constants Others:- AC 100 ~ 240V, 50/60Hz Weight: 6Kg without LCD screen Dimension: 460 x 420 x 80 mm
...moreAutoref-Keratometer
Our Autoref-keratometer comes with Elegant look with award winning design, latest software with attractive features are the prime attractions of New Ultra Series of Refractometers. 21st century image processing algorithm with unique Japanese ARM Processor is responsible for most accurate and fast measurement. Titable 5.7 inch hi-resolution color LCD display, allows the operator to access the machine in standing position. Motorized chin restcontrol makes it more comfortable for easy maneuever of the machine. On-Screen display of 10 measurements per eye with PD & average data for subjective test. Vertical Auto Tracking with BMM technology makes the machine faster accurate. Accurate & wide measurement range with Auto ,Manual & IOL mode of operation. Provides corneal curvature both in mm as well as in diopter (Only in KR 20+). Cornea & pupil size measurement in mm, through on-screen cursor adjustment. Faster & accurate reading with wider measuring area within small pupil. Compatible with Digital Auto Phoropter DAP-30+ BMM: Burst Measurement Mode:(3 readings in one shot)
...moreAuto Ref-Keratometer
Scienceter’s Axis TSRK-1000 Autoref Keratometer utilizes world acclamailed DSP engine (digital Sine Progression) technology for measuring, signal capturing, aiming and Data processing. Thereby ensuing most accurate measurements, imaging & results. The compact and fully loaded AXIS offers all technological utilities for today and tomorrow which makes it an ideal O.P.D. Companion. Its robust design & cutting edge technology, ensures years and years of trouble free performance. Salient Feature of the AXIS (TSRK-1000) Automatic Fogging: The AXIS incorporates Automatic fogging control by providing an infinity scene to control accommodation. A very handy tool required for accurate and typical measurements. High Resolution Colour LCD Monitor: 3,26,000 pixel, 6.4 Inches Bright TFT color LCD provides super fine and large iris image with color alignment marks and user friendly interface. Alignment Marks: AXIS automatically indicates to the user when ideal focus is achieved for enhanced accuracy and easy, fast measurements. User Friendly: Convenient & simple, user interface make AXIS ideally suited for multiple user environments too. Its easy and simple self explanatory display eliminates the need for use of manual. Pupil & CLBC Measurements: Pupillary Diameter: Special measurement made with image capture for accurate and reliable pupillary diameter measurement ideal for ICL and LASIK workup. AXIS Automatically calculates the inter-pupilary distance for both near and far vision. CLBC (Contact Lens Base Curve Measurement) Corneal & Iris size measurement can be done on the Aixs. Auto Measurement Mode: Ensures Easy, accurate quick measurement mode for uncooperative patients. Eye Diagram: AXIS provides the user with the option to print the Diagram of both myopic and hypermetropic eyes on the print out itself. Motorised Chin Rest: The AXIS incorporates motorized Chin-Rest Up-Down function with conveniently located controls on the front panel for use comfort and saves time Retro Illumination & Anterior Segment Photography-Imaging: This is very special feature which allows the user to take photographs of eyes with cataract. This helps in counseling the patient for further procedures.
...moreAScan biometer
Specifications : With rich industry experience, we are trading and supplying technically advanced AScan, which is a compact & light weight machine. Manufactured at vendors’ end as per international quality standards, our offered product is widely used for measuring axial length with anterior chamber depth, lens thickness & vitreous length of eye. This machine finds usage in various eye centers and is highly treasured due to its Strength user friendly interface perfect finish, high durability low maintenance. 1.Features: USB connectionIntegrated Image Capture, Patient Database , Report Editor. 2. A scan: Scan Mode: Contract/ImmersionExamination Modes:NormalAphakicDense catractPseudophakic(PMMA,Acrylic,Silicone)MeasurementsAXL,ACD,Lens and vitreousIndividual segment velocitiesAverage & standard Deviations for AXL,ACD,Lens & vitreous.SpecificationsClinical Accuracy +-0.1mmElectrical Accuracy 0.0375mmIOL calculation in 0.5D IncrementsIOL calculationSRK-IISRK-TBinkhorst-IIHolladayHoffer-QHaigis(standard) A-Scan/Pachymeter: Compact Body, Light Weight. Friendly LCD Touch Screen. Contact and Immersion Modes. Multiple IOL Power Calculation. Build-in Thermal Printer. Capable of Connecting to PC. Optional Workstation on PC. A-Scan: 10MHz Frequency Probe Axial Length: 14.0-46.0mm Clinical Accuracy: ±0.1mm Six IOL Formulas Available Pachymeter: 20MHz Frequency Probe 125-1000 microns Range Clinical Accuracy: ±10microns
...moreBe first to Rate
Rate This