Orifice Plate Flowmeter
Get Price Quote
Orifice Plate Flowmeter
Get Price Quote
Orifice Plate Flowmeter Series OP Orifice Plate Flowmeter The Series OP Orifice Plate Flowmeter is a complete orifice plate flow metering package. It incorporates a stainless steel orifice plate with a unique holder or carrier ring containing metering taps and integral gaskets. It was designed for use wherever there is an application for a conventional flow orifice plate. It can also be used in place of other primary differential producers for efficiency and cost effectiveness. Installation is accomplished simply by slipping the unit between standard flanges (orifice flanges are not required). The Series OP is available in line sizes from 1/2" to 24" and can be used with compatible liquids and gases. Features: Mounted with standard flanges Standard "corner tap" configuration Corrosion free material Simplified installation Built in metering taps (1/4" female NPT STD) Proven through a wide range of applications for accuracy and energy efficiency Assures long term reliability and accuracy Service : Compatible liquids and gases. Installation : Standard flange 125/150 rating. Pipe Requirements : General requirements 10 diameter upstream and 5 diameter downstream. Applications: Fluid flow rates in building water lines Boiler feedwater Cooling water Combustion or compressed air Steam flow Accuracy: The Series OP utilizes the corner tap proportions as defined in ISO 5167. While this code may not be referred to as International Standard until accepted by the ISO Council, the ASME Fluid Meters Research Committee has suggested that the dimensionless coefficient equation developed by the International Standards Organization (ISO) and presented in ISO 5167 is significantly better for the broad spectrum of flow measurement applications throughout process industries. The coefficient values used in the Series OP bore calculations represent the same confidence level assigned to the flange and radius taps widely accepted in fluid flow measurement. The accuracy assigned to the coefficient values is ±0.6% full scale flow for d/D (Beta) values 0.2 to 0.6 and ±0.7% for Beta values 0.7 to 0.75 (i.e. ß of 0.7 would have an uncertainty value of ±0.7% full scale flow). Accuracy of the differential signal produced by the Series OP equals or exceeds that of a properly manufactured and installed flange or radius tap orifice meter. Mounting: The orifice metering primary shall be suitable for installation between standard ANSI 125/150# flanges (any material) mounted on standard pipe (any material). The unit shall be "self centering" within the bolt circle of the flanges. No alignment of the orifice shall be necessary unless used with 300# or non-standard flange ratings. Drilling and or tapping of the main or flanges will not be allowed or required. The overall laying length shall be 1.25 including pre-attached ring type 1/8 ?? thick Buna "N" Gaskets. Pipe Requirements: Upstream and downstream pipe requirements are contingent upon two factors: (a) Beta Ratio-ratio of the orifice bore to the pipe I.D. (d/D); (b) The type of fitting or disturbance upstream of the Series OP. For most applications, 10 pipe dia. upstream & 5 dia. downstream are sufficient. (5 pipe dia. up and 2 dia. down are acceptable for non-critical application.) Type : Orifice Plate Flowmeter Material : Buna-N Gaskets. Accuracy : ±0.6% Full Scale Flow. (Beta= .2-.6) ±0.7% For Beta Greater Than .6. Application : Compatible Liquids And Gases. Certification : YES
Best Deals from Orifice Flow Meter
Orifice Flow Meter
Get Price Quote
We have come up as one of the most reliable Exporters and Suppliers of Orifice Flow Meter. The Orifice Flow Meter offered by us is a full feature-studded products with a guarantee of quality. The Orifice Flow Meter is known for its stable long-term accuracy and repeatability. With the use of Orifice Flow Meter, there is a reduced possibility of process fluid leakage. Also, this Orifice Flow Meter has a lower cost of installation than traditional orifice-type meters. To add to that, this highly efficient Orifice Flow Meter requires no special protection against extreme weather conditions. Highlights : Stable long-term accuracy and repeatability No routine maintenance required Lower cost of installation than traditional orifice-type meters Reduced possibility of process fluid leakage No moving parts to wear No special protection needed against extreme weather condition
Orifice Flow Meter
Get Price Quote
For low Flow applications, we offer specially designed Orifice Flow Metering Systems. The Orifice Flow Meter is known for its stable long-term accuracy and repeatability. With the use of Orifice Flow Meter, there is a reduced possibility of process fluid leakage. Also, this Orifice Flow Meter has a lower cost of installation than traditional orifice-type meters. To add to that, this highly efficient Orifice Flow Meter requires no special protection against extreme weather conditions.From low cost Volumetric measurement to specialized applications requiring on-line density correction, we offer complete integrated ready to use Orifice Flow Measurement systems.The orifice is designed for customer specific application , and integrated with the best of components from our own manufacturing range to provide you with the most accurate and predictable flow measurement solution.
Orifice Flow Meter
Get Price Quote
Orifice Flow Meter, Digital Flow Meter, electronic flow meter
Orifice Flow Meter
Get Price Quote
Orifice Flow Meter, Turbine Flow Meter for Sugar Mill, Oval Gear Flow Meters