Digital Vortex Flow Meter
Get Price Quote
1 Piece (MOQ)
MISSION- Digital Hb Meter
3,950 - 6,500 Per Set
01 Set(s) (MOQ)
Best Deals from Panel Meter
Digital Display Hour Meter
500 Per Piece
Digital Sound Level Meter
35,000 - 40,000 Per Piece
1 Piece (MOQ)
Digital Clamp Meter
Get Price Quote
Digital Ph Meter
Get Price Quote
NIG 333 Digital pH Meter
Get Price Quote
Range: pH: 0 - 14 pH. mV : 0 to ±1999mV, Resolution: pH:0.01pH, mV : 1 mV. Accuracy: pH : ±0.01pH ±1 digit, mV : ±1mV ±1 digit. Slope Correction: 80% to 120% . Temp. Compensation: 0-100°C Manual & (Automatic optional). Indication: 3 ½ digit LED (12.5 mmhigh). Power Supply: 230 V ±10%, 50 Hz AC. Input Resistance: 10^12 ohms. Ambient Temp.: 10° C to 50° C. Dimensions (L x B x H): 210 x 190 x 90 mm. Weight: 3.0 Kgs. Accessories: pH Electrode, Electrode stand, Dust Cover, Instruction manual, buffer solutions.
Ultrasonic Pulse Velocity Meter
Get Price Quote
At present the ultrasonic pulse velocity method is the only one of this type that shows potential for testing concrete strength in situ. It measures the time of travel of an ultrasonic pulse passing through the concrete. The fundamental design features of all commercially available units are very similar, consisting of a pulse generator and a pulse receiver. Pulses are generated by shock-exciting piezo-electric crystals, with similar crystals used in the receiver3. The time taken for the pulse to pass through the concrete is measured by electronic measuring circuits. Pulse velocity tests can be carried out on both laboratory-sized specimens and completed concrete structures, but some factors affect measurement: 1. There must be smooth contact with the surface under test; a coupling medium such as a thin film of oil is mandatory. 2. It is desirable for path-lengths to be at least 12 in. (30 cm) in order to avoid any errors introduced by heterogeneity. 3. It must be recognized that there is an increase in pulse velocity at below-freezing temperature owing to freezing of water; from 5 to 30°C (41 - 86°F) pulse velocities are not temperature dependent. 4. The presence of reinforcing steel in concrete has an appreciable effect on pulse velocity. It is therefore desirable and often mandatory to choose pulse paths that avoid the influence of reinforcing steel or to make corrections if steel is in the pulse path. Applications and Limitations. The pulse velocity method is an ideal tool for establishing whether concrete is uniform. It can be used on both existing structures and those under construction. Usually, if large differences in pulse velocity are found within a structure for no apparent reason, there is strong reason to presume that defective or deteriorated concrete is present.
Digital 3 Phase Multifunction Meter
Get Price Quote
CSM Series is a powerful Microprocessor based digital panel meter series with built in intelligence that offer comprehensive 3 phase electrical instrumentation and load management facility in a compact and rugged package.The CSM series comes with optional RS-485 communication port for integration with SCADA and Energy management software system. Benefits Communication with PLCs, DCS through optically isolated RS-485. Current, voltages, frequency, active (kW ), reactive and apparent power, power factor. Average current, power, voltage & frequency. Compact size of 96 x 96 mm. FEATURES Accuracy as per IEC 61036. True RMS measurement. Password protected parameter. Auto scrolling of parameter. Programmable CT/PT Ratio Compact size of 96 x 96 mm Micro processor based Digital Panel Meter Series
Gloss Meter
Get Price Quote
Gloss meter is used to analyze the cosmetic appearance of the coating for test the finish of the coating accurately. Gloss meter directs a beam of light to the surface to be tested at a specific angle & measures the amount of reflection in order to determine the gloss.
Digital Conductivity Meter
Get Price Quote
Read out : Digital bright, LED type 3½Indication : Direct conductance & resistance.Range Conductance :0. 01 Micro ohm to 1000 MhoResistance : 1 ohms to 2 M ohmsAccuracy Conductance : ± 0.5% of range ±1digitAccuracy Resistance : ± 1% of range ± 1digitCell constant compensation : 0.5 to 1.5Power Requirements : 230V± 10% AC 50 Hz
LOW FLOW RATE FLOW METERS
Get Price Quote
These are ideal for laboratory or instrumentation applications. Mounting can be panel or by optional tripoid base. Available in complete acrylic body or stainless steel body with glass metering tube. Purge Rotameters are economical and suitable for low flow rate indication for fluids. These are available in all standard material of construction and can be offered with a flow regulating needle valve to give a constant flow irrespective of the supply or upstream pressure.
Digital Multimeter
17,800 Per Piece
DIGITAL HEMOGLOBIN METER
3,500 - 4,500 Per piece
Digital Meter
Digital Panel Meters
600 Per Piece
We are the main supplier of this product.
Gloss Meter
Get Price Quote
Gloss Meter, Liquid Flow Controller, Exhaust Gas Analyzer, Emission Analyser
VAF Meter
Get Price Quote
VAF Meter, Engine Safety Unit, Cyclic Timers AC Star Delta Timer
Digital Panel Meters
Get Price Quote
Digital Panel Meters, digital process indicators