Plate Load Test Equipment Dealers in Laxmi Nagar, Delhi

(21 products available)
  • Tablet Disintegration Tester

    Tablet Disintegration Tester

    90,000 - 95,000 Per Piece

    1 Piece (MOQ)

    • Color: White
    • Condition: New
    • Automatic Grade: Semi Automatic
    • Certification: ISO 9001:2008 Certified
    • Feature: Easy To Use
    • Type: Tablet Disintegration Tester
    • Country of Origin: India
    • Warrenty: 1year

    Type of Heating Hot Plate Up-Down Speed 30 ÷2 stroke/min Time Control 59 hr, 59min, 59 sec No. of Basket Two Audio Alarm Yes Play & pause Yes

    more..
  • Water and Soil Analysis Kit

    Water and Soil Analysis Kit

    Get Price Quote

    Water and Soil Analysis Kit that we manufacture, export and supply is very easy to operate by simply putting the F2 switch to standby position and switch on the instrument. The display will indicate 000 at the start. It is advisable to clean the membrane with a soft tissue paper after every use. Our Water and Soil Analysis Kit is appreciated for its accuracy in measurements and portable size. It is available in an easy-to-use kit.   pH Measurements : Put the function switch to pH / Orp mode. Wash the electrode with distilled water and dry it with filter water Connect the electrode BNC plug at the input socket Put the combination pH electrode in buffer solution 7.00 pH. Set the Temp. Knob to the Temp. Of the buffer solution. Now move the switch F2 to pH mode. Read the display value, adjust it with Cal control to 7.00 pH value. Again Move the selector switch F2 to Stand by mode. Take out the electrode from 7.00 pH buffer and wash it with distilled water and dry it with filter paper. Put the electrode in 4.00 pH solution. Set this value to 4.00 pH by setting Slope control. The instruments is ready to take measurements.   O.R.P. Measurements : Put the function Switch F1 to pH/ORP mode. Rinse the CRP electrode with distilled water and dry it with filter paper. Connect the ORP electrode BNC plug at Input socket. Take 0.00 mV buffer solution freshly prepared and calibrate with Cal knob. The instruments is calibrated and ready for taking ORP measurement of any other solution.   Conductivity Measurements : Put the function switch at Cell Const Position Adjust the display to the cell constant value marked on the conductivity cell supplied with the instrument. Now move the switch to the COND. Position Put the range switch at appropriate positions so that best possible resolution is obtained.   TDS Measurements : Put the function switch at TDS Position Clean the conductivity cell, dry it and connect in cond/TDS input socket. Adjust the display to cell constant value marked on conductivity cell by cell const, knob and function switch at Cell const position. Dip the cond. Cell in the unknown solution whose TDS value to be measured. Put the range switch at appropriate PPM/PPT position, so it best possible resolution is obtained.   Cell Constant Measurement : It is recommended that cell constant of the conductivity cell must checked off and on. This can be done as follows : Dip the conductivity cell in a solution of known conductivity. (1408µmhos) Keep the function switch Fat Cond position. Adjust the display to the value of known solution by rotating CE Constant Knob. Bring function switch F to Cell const. Position. The display will indicate the cell constant of the conductivity cell.   D.O. Measurements is done by following steps : D.O. Probe Assembly D.O. Probe consist of a silver and gold electrode cells, an electrolyte tube with thering.   The following procedure may be followed for assembly or D.O. Probe Be careful to handle its membrane. Fit the membrane on the lower part of the electrolyte tube. Fix the ring on the electrolyte tube covering the sides of the membrane. Fill Potassium chloride solution (7.5%) in the electrolyte tube to its top. Insert the electrode in the electrolyte tube and tightly screw it up. Now the probe is ready to use.   D.O. Operation : Put the function switch F1 to D.O. Mode and adjust the display to Co.o with Zero knob and insert the D.O. Probe in D.O. Sockets. Please keep colour code in consideration. Keep the Temp knob to the extreme left position and Cal Knob to extreme right position. Place the D.O. Probe in 2% sodium Sulphite solution. Allow the display to attain equilibrium. If the display does not read 000, set the zero knob to bring the display to read 000 by keeping the temp. Knob to actual temp. Of the solution. Calibrate knob should be at extreme right position. Now Calibrate the instrument with known value of D.O. Solution Take 250 ml. Flash and fill 2/3 of it with distilled water. Stopper the flash and shake it for 30 seconds. Remove the stopper back and siri the water back and repeat the procedure 4 times. Measure the temp. Of the water and set the temp. Knob at temp of water in the flask. Hold do probe in the flash and agitate the water. Note the reading of the display and check the value with that of the table below for given temperature. If necessary adjust the meter reading with CaL knob.   Note : Please refer to the saturation values of the dissolved Oxygen in distilled water as given in Table 1. it shows the values for dissolved oxygen which will be obtained when shaking the distilled water at different temp. In the air. Now the instruments is ready to take measurements of D.O. Value of any unknown solution   Caution : Since the measurement is based on the diffusion process, the agitation of the solution is must. Hand shaking of the solution may not give accurate readings, magnetic stirrer is recommended for this purpose. Movement of the solution should be about 2ft/sec for accurate measurement. BOD bottle is recommended as a container for measurement of sample solution in the laboratory. Because DO probe tight fits in BOD bottle and no atmospheric oxygen may dissolve during measurement.   Maintenance of D.O. Probe : Do not touch the silver electrode of the probe. The Membrane must not have any pin hole, puncture. The DO reading will be erratic at constant DO concentration and temperature, if the membrane has a puncture. Any accumulation of organic matter on the membrane will effect the Cal. It is advisable to clean the membrane with a soft tissue paper after use.

    more..
  • Best Deals from Plate Load Test Equipment

  • leak test apparatus

    leak test apparatus

    28,000 Per Piece

    2 Piece(s) (MOQ)

    • Brand Name: Micronvac
    • Condition: New
    • Warranty: 1 Year
    • Material: Stainless Steel
    • Application: Leak Testing
    • Voltage (V): 220
    • Vacuum Level (mm): 760mmhg
    • Display: Digital
    • Speed (RPM): 1440rpm
    more..
  • Dissolution Test Apparatus

    Dissolution Test Apparatus

    250,000 - 260,000 Per Piece

    1 Piece (MOQ)

    • Material: Mild Steel
    • Certification: CE Certified, ISO 9001:2008
    • Application: Dissolution Testing
    • Color: Grey, Light White, Off White
    • Voltage: 220V
    • Condition: New
    • Dimension: 340mmx330mmx475mm
    • Power: 1KV
    • Driven Type: Electric
    • Phase: Single Phase
    • Warranty: 1yrs
    • Temperature: 0-50°C
    more..
  • Cold Bend

    Cold Bend

    Get Price Quote

    • Model: SSI 506 CBIE (Cold Bend Test Apparatus as per IEC Standard.
    • Stand Construction: Made of MS, hard chromed
    • Mandrels: 4 Mandrels of 5,10,20,30 mm Dia.
    • Sample Rotation: Using geared pulley to wound sample around the mandrel

    Cracks and deformation occur when the material is bend or wound under cold conditions. The apparatus is deigned to wound the cable samples on standardized mandrels under cold conditions.

    more..
  • Jar Testing Apparatus

    Jar Testing Apparatus

    9,000 Per Piece

    1 Piece (MOQ)

    • Material: Stainless Steel
    • Voltage: 220 V
    • Brand: Precious Techno Engineering
    • Automation Grade: Automatic
    • Power Source: Electric
    • Frequency: 50/60 hz
    • Speed: 20 to 180 RPM
    • Weight: 20 kg
    • Motor Power: 20 HP
    more..
  • Tablet Friability Apparatus

    Tablet Friability Apparatus

    66,000 Per Piece

    • Voltage: 220V AC
    • Type: Tablet Testing
    • Model: EF2W
    • Display: LCD
    • No. Of Drums: One / Two
    • Interfaces: RS232
    • Number Of Revolutions: 20 to 50 RPM
    • I deal in: New and Second Hand
    more..
  • Tablet Friability Apparatus

    Tablet Friability Apparatus

    Get Price Quote

    • Type: Tablet Friability Test Apparatus
    • Application: Friability Testing
    • Color: Brown, Light White, Off White, Silver
    • Voltage: 110V, 220V, 380V, 440V
    • Condition: New, Used
    • Power: 1KV, 2KV, 500W, 750W
    • Driven Type: Electric, Hydraulic, Mechanical, Pneumatic
    • Warranty: 1yrs, 2yrs
    • Material: Mild Steel, Stainless Steel
    • Phase: Double Phase, Single Phase, Triple Phase
    • Temperature: 0-50°C, 100-200°C, 200-400°C, 50-100°C
    more..
  • Density Meter

    Density Meter

    350,000 Per Piece

    • Density: 0 to 3 g/cm3
    • Temperature: 15 Degree C to 60 Degree C (controlled Via Peltier)
    • Pressure: 0 to 10 Bars
    • Measurement Modes: Continuous, Single, Multiple
    • Repeatability: 0.0001 g/cm3 (Extra Resolution Available)
    • Minimum Sample Volume: Less than 1 mL
    more..
  • Blood Roller Mixer

    Blood Roller Mixer

    Get Price Quote

    5 Piece (MOQ)

    • Country of Origin: India
    • Voltage: 220 / 230 V
    • Dimensions: 455 x 265 x 120 mm
    • Frequency: 50 Hz
    • Maximum Load: 5 Kg
    • Rolling Speed: 10 - 30 RPM
    • Body Material: MS Coated

    Description: The BRADLEYVACUTUBE Blood Roller Mixer Tube Mixer, available in a convenient pack of 1 piece, redefines sample mixing with precision and reliability. Engineered for optimal performance in blood sample preparation, this mixer ensures thorough and consistent mixing, essential for accurate analytical results in clinical and research laboratories. Key Features: Variable Speed Control: The Blood Roller Mixer Tube Mixer by BRADLEYVACUTUBE features variable speed control, allowing users to tailor the mixing speed to the specific requirements of their applications. This adaptability is particularly valuable for diverse blood sample preparations, ensuring gentle yet effective mixing. Tube Capacity and Compatibility: Designed to accommodate a single tube, this mixer caters to the specific needs of laboratories requiring focused mixing of individual blood samples. The adjustable rollers ensure compatibility with various tube sizes, providing versatility in sample processing. Quiet and Smooth Operation: The mixer operates with minimal noise, creating a conducive laboratory environment. Its smooth and quiet operation is achieved through precision engineering, minimizing disturbance during critical sample processing procedures. Benefits: Uniform Sample Homogenization: The variable speed control and optimized roller design of the Blood Roller Mixer ensure uniform sample homogenization. This is crucial for obtaining consistent results in hematological analyses, facilitating accurate and reproducible data. Time-Efficient Processing: With its single-tube design and efficient mixing capabilities, the BRADLEYVACUTUBE Blood Roller Mixer expedites sample preparation workflows. Researchers can save valuable time without compromising the quality of sample homogenization, enhancing overall laboratory efficiency. Compact and User-Friendly: The compact design of the mixer allows for easy integration into laboratory spaces of varying sizes. Its user-friendly interface ensures straightforward operation, making it an accessible tool for both experienced researchers and laboratory professionals.  

    more..
  • Reynolds Apparatus

    Reynolds Apparatus

    Get Price Quote

    The flow may be laminar or turbulent. Osborne Reynolds (23 August 1832 - 21 February 1912) was a prominent innovator in the understanding of fluid dynamics and mechanics. Osborne Reynolds Apparatus consists of water resource for the system supply, fix-head water input to big and small transparent pipes, dye input by injection unit, and water output unit to determine water flow rate. The laminar, transition and turbulent flows can be obtained by varying the water flow rate using the water outlet control valve

    more..
  • Soil Permeability Apparatus

    Soil Permeability Apparatus

    Get Price Quote

    Soil Permeability Apparatus is used for the laboratory determination of permeability of soils using a constant or a variable head. This test is recommended for soils with coefficient of permeability in the range of 10-3 to 10-7 cm/sec. The maximum particle size of the soil which can be tested in the mould is 10 mm. Standard: IS: 2720 (Part XBII), ASTM D 2434. SPECIFICATIONS: The equipment comprises one each:   Gun metal mould, 100 mm I.D x 127.3 mm high x 1000 ml volume. Extension collar, 100 mm dia x 60 mm high for the above mould. Drainage base plate with a recess for a porous stone and with an outlet valve. Metallic clamping ring. Drainage cap (Top plate with a recess for a porous stone and fitted with an inlet valve and an air release valve.) Dummy plate to serve as a false bottom during compaction. Porous stone for drainage cap. Porous stone for base plate. Set of Three glass stand pipes approximately 6 mm dia., 10 mm dia and 20 mm dia mounted on a wooden board. Each glass tube is longer than 1 meter and has a serrested end at the bottom. To read water head 2 Nos. meter scales are fixed between the tubes.   A length of 3 meter long rubber tubing with pinch cock is also supplied. 

    more..
  • Tablet Friability Apparatus

    Tablet Friability Apparatus

    Get Price Quote

    Features : Automated sample discharging Filling of samples into the drum without removing the drum Unique front loading system Supports the friabilator and the abrasion drum 10 deg till of the bench top as per USP Variable speed from 20 to 40 RPM Programmable counter/ timer- validation of RPM and count. 24 x 2 character LCD display Calculation of result like % friability, weight- lost RS-232 interface for weighing scale, supports mettle, Sartorius. Parallel port for complete test report with validation printout. Real time clock

    more..
  • Fume Hood

    Fume Hood

    Get Price Quote

    Fume Hoods are designed to ensure good working condition by protecting from toxic fumes. Vapours, dust, chemical spillage, Over run of reaction, Flames. Bio Gene uses very powerful exhaust fan blower to suck the contamination and dispose along with water curtain.

    more..
  • bitumen testing equipment

    bitumen testing equipment

    Get Price Quote

    • Features: Easy to installed, Low maintenance, Strong construction, Excellent finish, High strength
    more..
  • Speedy Moisture Meter MACHINE

    Speedy Moisture Meter MACHINE

    Get Price Quote

    Our organization is well known in the market and has managed to carve a niche in the industry for the supply of a wide range of Speedy Moisture Meter. Following industry norms and standards, the range is designed and manufactured in different technical specifications based on the requirements of the clients.Precision designed, the range comprises: A pressure vessel with clamp for sealing cap, capacity is 20gms Rubber sealing gasket Pressure gauge calibrated in percentage moisture content 0-25% x 25% on the wet weight basis, An electronic balance for weighing sample A scoop for measuring carbide reagent A bottle of reagent One cleaning brush and a set of 4 steel balls for through mixing Complete in highly polished wooden carrying case with handle

    more..
  • Triaxial Cell

    Triaxial Cell

    Get Price Quote

    Triaxial Cell, analytical equipment, Turbiscan Tower Dispersion Analyser

    more..
  • Aggregate Impact Testing Apparatus

    Get Price Quote

    Aggregate Impact Testing Apparatus, Rockwell Hardness Testing Machine

    more..
  • Fume Hood

    Get Price Quote

    Fume Hood, autoclave instrument, Laboratory Instruments

    more..
  • Jar Test Apparatus

    Get Price Quote

    Jar Test Apparatus, Rotary Vacuum Evaporator

    more..
Filter by Locality
top