BM-xx00-RM1K Wireless IO Radio Kit
How many times do you need to get a few points of digital or analog inputs and outputs from point A to point B, but can’t justify the cost of running the wires? The Radio Kit is a replacement for hardwired IO that is simple to deploy. The Kit requires no programming – just wire strippers and a screwdriver. There is no communication protocol to interpret. The radios are paired and secured at the factory, so there are no settings or configurations to figure out. It is bi-directional, so digital and analog signals can be sent in both directions between two connected IO stations. Inputs on one module are simply replicated as outputs on the corresponding module. Our wireless IO makes use of the unlicensed ISM band at either 868 MHz, 900 MHz, or 2.4 GHz (USA only). The radios can send IO up to 4 miles for the 900 MHz or 1 mile for the 868 MHz and 2.4 GHz models. Each radio pair can connect up to 16 IO modules, more than enough for most applications.
Feature : Save time and money: Eliminates trenching and running conduit / deploys in minutes,Easy to use: No software configuration needed
...moreSM General Communication Protocol Module MVI56-SMGC
The MVI56-HART Master Multi-drop Network Interface Module allows ControlLogix IO compatible processors to easily communicate with HART slave devices. The MVI56-HART module interfaces up to 15 devices on each HART channel with the ControlLogix processor. Four channels on the module support master protocol commands to interface with slave devices on their own networks. Each port is individually configurable. Data is exchanged between the HART network and the ControlLogix processor using the internal database contained in the module and direct control by the processor's ladder logic and pre-defined data objects (5000 registers maximum). The MVI56-HART module is the perfect solution for industrial applications in chemical and refining operations, gas and liquid distribution systems, and remote offshore monitoring stations, addressing virtually all aspects of control, data acquisition, and maintenance.
...moreSiemens Industrial Ethernet Communication Module
The MVI56E Siemens Industrial Ethernet Communication Module allows Rockwell Automation ControlLogix Programmable Automation Controllers (PACs) to interface easily as an Ethernet Client with up to a maximum of 20 Siemens S7-200, S7-1200, S7-300, and S7-400 PLCs operating as Ethernet servers. The module uses ProSoft Configuration Builder (PCB) which provides a graphical configuration tool for management of module configuration files, as well as viewing communication and module diagnostic information using the high-speed Ethernet port. Commands are enableddisabled from ladder logic enabling various Siemens S7 CPUs to support multiple applications without having to reconfigure the module. Data transfer to a ControlLogix ® PAC uses scheduled IO data for faster updates and better performance.
...moreSiemens 3964R Network Interface Module
The module is ideal in control configurations where there is a need for the CompactLogix processor to exchange data with other non-Rockwell Automation control devices in low speed applications. The MVI69-S3964R can communicate with devices using two RS-232, RS-422 communication lines (ports). The ports operate independently from each other.
Feature : The 3964R protocol was designed by Siemens for bidirectional data communication through a point-to-point connection
...morePSW-PWD ProSoft Wireless Designer software
ProSoft Wireless Designer simplifies the task of planning and specifying your ProSoft Wireless network. The easy to use, wizard-based interface creates a visual layout of your radios and sites, and generates a complete Bill of Materials including radios and accessories.
Features : Visual diagram of site layout Location (latitude/longitude, based on GPS coordinates)
...morePSW-PCB ProSoft Configuration Builder software
Use a single software tool to configure and test all ProLinx modules, as well as a growing selection of ProSoft inRAx and ProTalk modules. ProSoft Configuration Builder simplifies the task of managing the configuration files that control how your ProSoft module operates. ProSoft Configuration Builder also provides the following features: Graphical User Interface replaces the Hyperterminal download and monitor method. Provides error reduction in setting up configuration files. Extensive online help for module-specific configuration options.
Features : . Create plant-wide configurations of all ProSoft Technology products. Manage configuration of complex protocols and networks, including PROFIBUS DP.
...morePSW-AFC ProSoft AFC Manager monitoring tool
The AFC Manager is an easy-to-use Windows 98NT2000XP based configuration, reporting, and monitoring tool provided with the AFC modules. Project configurations may be uploaded, downloaded and saved to the PC under user selectable file names.
Features : Monitor the meter operation , Perform an audit scan , Configure the archives
...moreILX69 PROFIBUS Slave module
The ILX69 PROFIBUS Slave module is an in-chassis PROFIBUS DPV1 Slave for CompactLogix, supporting cyclic PROFIBUS IO data and acyclic messaging. Explicit ladder logic CIP message blocks provide slave status diagnostic data and the ability for acyclic messaging.The ILX69 interface appears to the CompactLogix controller as a standard IO module allowing it to be configured via StudioRSLogix™5000. The cyclic PROFIBUS IO data can be configured in StudioRSLogix™ 5000, or configuration can be transferred from the Master to the slave module. The Ethernet interface allows for remote diagnostic and troubleshooting. Complete program examples for simple and quick start-up are available.
Feature : Rockwell Automation Encompass Approved PI Certified Remote diagnostics via Ethernet
...morePROFIBUS DPV1 Slave for CompactLogix
The ILX69 PROFIBUS Slave module is an in-chassis PROFIBUS DPV1 Slave for CompactLogix, supporting cyclic PROFIBUS IO data and acyclic messaging. Explicit ladder logic CIP message blocks provide slave status diagnostic data and the ability for acyclic messaging.The ILX69 interface appears to the CompactLogix controller as a standard IO module allowing it to be configured via StudioRSLogix�5000. The cyclic PROFIBUS IO data can be configured in StudioRSLogix� 5000, or configuration can be transferred from the Master to the slave module. The Ethernet interface allows for remote diagnostic and troubleshooting. Complete program examples for simple and quick start-up are available.
...morePROFIBUS DPV1 PS69 Master Network Interface Module
The PS69 PROFIBUS DP Master module expands the functionality of ’s CompactLogix MicroLogix family of processors to include PROFIBUS. This module supports both IO control and messaging, thus integrating DPV0 and DPV1 functionality into CompactLogix MicroLogix. The PS69-DPM is a CompactLogix MicroLogix compatible, PROFIBUS certified module, which enables controllers to communicate with a PROFIBUS network. The configuration and diagnostic of the PROFIBUS system is done via the serial diagnostic interface of the module using the System Configuration tool . The data exchange between controller and module is done via the IO process data image using CompactLogix MicroLogix backplane technology.
...moreILX69-PBM PROFIBUS DPV1 Master module
The ILX69-PBM PROFIBUS DPV1 Master module provides all the advantages of in-chassis PROFIBUS communication, such as the inclusion of an AOI and the Autoscan features which greatly reduce your commissioning time, and ComDTM that provides remote Ethernet connectivity with asset management software. With these modules, CompactLogix™ processors can easily communicate with slave devices supporting PROFIBUS DPV0 and DPV1 protocol. The module acts as an inputoutput module between the PROFIBUS network and the processor supporting complete Master specifications according to IEC 61158.
...morePROFIBUS DPV1 Master for CompactLogix
The ILX69-PBM PROFIBUS DPV1 Master module provides all the advantages of in-chassis PROFIBUS communication, such as the inclusion of an AOI and the Autoscan features which greatly reduce your commissioning time, and ComDTM that provides remote Ethernet connectivity with asset management software. With these modules, CompactLogix� processors can easily communicate with slave devices supporting PROFIBUS DPV0 and DPV1 protocol. The module acts as an inputoutput module between the PROFIBUS network and the processor supporting complete Master specifications according to IEC 61158.
...moreN2 Systems Communication Module
The SlotServer ControlLogix Metasys N2 by JCI Communications Interface allows an Allen Bradley ControlLogix platform to pass data between a ControlLogix CPU and Johnson Controls Metasys N2 networks. The Metasys N2 SlotServer can be configured as a Metasys Slave or Master enabling exchange of information between Metasys Master devices such as NCM, N-30, NAE or NIE) or Metasys Slave devices such as UNT, VMA, DX9100, VAV or AHU. Physically configured to plug into a standard ControlLogix rack, the SlotServer Module is configured for the 1756 platform using standard RSLogix message block reads to allow for efficient transfer of large blocks of data. Specific configuration data is contained in the Configuration CSV file downloaded to the module. SlotServer is a flexible communications module that can be configured to communicate to a wide range of protocols found in the extensive FieldServer Technologies library of protocols. The SlotServer is recognized as an inputoutput module by ControlLogix and has access to processor memory for data transfer between processor and module.
...moreMulti-Point Wireless I O Radio Kit
ProSoft Technologys Multi-Point Wireless IO system allows you to monitor IO from multiple locations without running long wires. This secure, reliable system is scalable and deploys quickly, allowing you to skip trenching, conduit, and permits. Three module types: Analog 0-10 V, Analog 4-20 mA, and DigitalDiscrete – give you the freedom to customize your setup based on your environment and needs. The system can be used in different methods: IO to IO, IO to Modbus serial communications, and Modbus® serial to Modbus Serial communications. This peer-to-peer system can move data from the IO or Modbus devices to any other node. The digital input module can act as a counter and send the accumulated value to another location.
Feature : Single power termination per station saves wiring time.,AES encryption ensures data is protected from intrusions
...moreMulti-Point Wireless input output Radio Kit
ProSoft Technology’s Multi-Point Wireless IO system allows you to monitor IO from multiple locations without running long wires. This secure, reliable system is scalable and deploys quickly, allowing you to skip trenching, conduit, and permits. Three module types: Analog 0-10 V, Analog 4-20 mA, and DigitalDiscrete – give you the freedom to customize your setup based on your environment and needs. The system can be used in different methods: IO to IO, IO to Modbus serial communications, and Modbus® serial to Modbus Serial communications. This peer-to-peer system can move data from the IO or Modbus devices to any other node. The digital input module can act as a counter and send the accumulated value to another location.
...moreModbus TCP Server Enhanced Network Interface Module
When you need Modbus TCPIP communications, the MVI56E- MNETCMNETCXT is the module of choice. The Modbus TCPIP Enhanced Communications Module allows Rockwell Automation® ControlLogix® Programmable Automation Controllers (PACs) to interface easily with Modicon® Programmable Automation Controller (PACs), as well as multiple Modbus TCPIP server-compatible instruments and devices. The multi-client module improves performance when controlling multiple servers on a Modbus TCPIP network, by supporting up to 30 Clients. It also supports up to 20 server connections providing the ability to communicate with other DCS and SCADA systems. Both client and server functionality can run simultaneously, allowing the module to operate as a powerful data concentrator. The MVI56E-MNETC and MVI56E-MNETCXT are functionally the same. The MVI56E-MNETC is designed for standard process applications. The MVI56E- MNETCXT is designed for the Logix-XT™ control platform, allowing it to operate in extreme environments. It tolerates higher operating temperatures, and has a conformal coating to protect it from harsh or caustic conditions. MVI56E enhancements include configuration and management through the module’s Ethernet port, and CIPconnect® technology for bridging though ControlNet™ and EtherNetIP™ networks.
...moreModbus TCP/IP Multi Client Enhanced Network Interface Module
The MVI56E Modbus TCPIP Multi Client Enhanced Communication Module for Remote Chassis allows Rockwell Automation ControlLogix Programmable Automation Controllers (PACs) to interface easily with multiple Modbus TCPIP server-compatible instruments and devices. The Multi Client module improves performance when controlling multiple servers on a Modbus TCPIP network, by supporting up to 30 clients. MVI56E enhancements include configuration and management through the module Ethernet port, CIPconnect technology for bridging through ControlNet and EtherNetIP networks, and has a web server to access on-board documentation, Add-On Instructions, and sample program files. This module uses a small IO data image for transfer of data between the module and the ControlLogix processor, making it ideal for ControlNet or Ethernet applications with the module in a remote rack.
...moreIP Lite Communication Module
The MVI69L-MBTCP Modbus TCPIP module is ideal for smaller applications that utilize the CompactLogix L2 controllers. The module has an Add-on Profile and an Add-on Instruction to reduce commissioning time. The MVI69L-MBTCP has a single Ethernet port for diagnostic and application data. It supports both Client and Server connectivity to interface with a variety of devices using the Modbus TCPIP Protocol
...moreModbus TCP/IP Enhanced Communication Module MVI69E-MBTCP
The MVI69E-MBTCP Modbus TCPIP module for the CompactLogix™ series of controllers is designed for all applications requiring Modbus TCP connectivity. This module comes with an Add-on Profile and an Add-on Instruction to reduce commissioning time. The MVI69E-MBTCP has a single Ethernet port for diagnostic and application data. The module supports both Client and Server connectivity to interface with a variety of devices using the Modbus Protocol.
...moreIP Client Server Network Interface Module
MVI46-MNET The MVI46 Modbus TCPIP Network Interface Module is designed to allow SLC processors to interface easily with other Modbus TCPIP protocol-compatible devices using client and server functionality. Compatible devices include not only Modicon processors (which support the Modbus TCPIP protocol) but also a wide assortment of other clients and server devices.
...moreModbus TCP/IP Client/Server Enhanced Network Interface Module for ControlLogix
The MVI56E Modbus TCPIP ClientServer Enhanced Communication Module allows Rockwell Automation ControlLogix processors to interface easily with Modicon Programmable Automation Controllers (PACs) and a wide variety of Modbus TCPIP-compatible instruments and devices. MVI56E enhancements include local and remote configuration and diagnostics through the module's Ethernet port, CIPconnect technology for bridging though Rockwell Automation ControlNet and EtherNetIP networks, and an on-board web server for access to module documentation and sample program files. The MVI56E-MNET and MVI56E-MNETXT are functionally the same. The MVI56E-MNET is designed for standard process applications. The MVI56E-MNETXT is designed for the Logix-XT control platform, allowing it to operate in extreme environments, at higher operating temperatures, and has a conformal coating to protect it from harsh or caustic conditions.
...moreCompactLogix L1 Modbus Serial Module
ProSoft Technology’s ILX34-MBS485 module is ideal to connect multiple devices up to 4,000 feet (1,219 meters) from your processor. These include SCADA and field device interface applications. The module can be used in CompactLogix L1 processors or Distributed 1734 Point IO systems. In addition, the module can be configured as a Master or Slave.
Features : Suitable for SCADA and field device interface applications,Supports up to 1,000 words of data
...moreModbus Serial Lite Communication Module
MVI69L-MBS The MVI69L-MBS, Modbus Serial module for the CompactLogix™ series of controllers is designed for smaller applications where communication between a few Modbus Serial devices is required. This module has an Add-on Profile and an Add-on Instruction to reduce commissioning time. The MVI69L-MBS has a single serial port and can support either Master or Slave connectivity to interface with a variety of devices using the Modbus Protocol.
...moreModbus Plus Dual Port Network Interface Module
The MVI46 Modbus Plus Dual Port Network Interface Module allow Rockwell Automation SLC processors to connect directly on Modbus Plus networks as a peer. The module acts as an inputoutput module between the Modbus Plus network and the processor. Compatible devices can be found in most industries and include devices such as drives, relays and power monitor hardware.
...moreMessage Manager for Industrial Communication ILX56-MM
The ProSoft Technology inRAx Message Manager is a single-slot solution that connects and transfers Factory and Plant Process Automation monitoring and control data between islands of automation across diverse platforms, networks and protocols. The inRAx Message Manager is an easy-to-use data transfer engine for the ControlLogix 1756 platform, supporting Rockwell Automation Programmable Logic Controller (PLC) and Programmable Automation Controller (PAC) network protocols, as well as platforms and devices that use Siemens Industrial Ethernet and Modbus TCPIP protocols. The ILX56-MM makes it easy for System Integrators and End Users to reduce the engineering effort required to coordinate data transfers between multiple control systems in Factory and Plant Automation applications. The Message Manager simplifies and streamlines data connection and transfer operations by enabling PLCPAC data exchanges without the need for additional message-specific PLC programming.
Features : The Message Manager acts as a communication interface as well as a message transaction engine
...moreBe first to Rate
Rate This