APM 550 Respirable Dust Sampler
Get Price Quote
The APM 550 system is a manual method for sampling fine particles (PM2.5 fraction) and is based on impactor designs standardized by USEPA for ambient air quality monitoring. Ambient air enters the APM 550 series samplers system through an omni-directional inlet designed to provide a clean aerodynamic cut-point for particles greater than 10 microns. Particles in the air stream finer than 10 microns proceed to a second impactor that has an aerodynamic cut-point at 2.5 microns. The air sample and fine particulates exiting from the PM 2.5 impactor are passed through a 47 mm diameter Teflon filter membrane that retains the fine particulate matter. The sampling rate of the system is held constant at 1 m3hr by a suitable critical orifice. The standard system is supplied with a Dry Gas Meter to provide a direct measure of the total air volume sampled. Special features: PM10 and PM2.5 Impactors of sampler based on designs standardized by US EPA Two part cabinet ensures that temperature of PM 2.5 filter remains close to ambient temperature Imported brush-less pump with a low noise Lower sampling rate of 1m3hr reduces filter choking even in areas having high FPM levels Critical Orifice maintains constant sampling rate of 1 m3hour Compact and portable
Respirable Dust Sampler
33,400 Per Piece
1 Pack(s) (MOQ)
Best Deals from Respirable Dust Sampler
Respirable Dust Sampler 22
Get Price Quote
We are offering respirable dust sampler. sle-rds103 suspended particles matter( spm) which is defined as particles less that 100 microns & respirable suspended particle less than 10 microns have emerged as the most critical among all the criteria air pollutants & is caused by number of sources like large, medium & small-scale industries, road dust construction activities, house hold fuel cooking, waste burning, vehicular emissions etc. in order to control the pollution, it is necessary to periodically monitor the air to determine the extent of pollution and to identify the source of emission sle-rds103 is designed to meet these needs. This model confirms to guidelines of central pollution control board. special features 1 low noise operations 2 brushless blower 3 portable for easy transportation 4 controlled flow 5 spm of particle size less than 100 microns 6 rspm of particle size less than 10 microns principles suspended particles in the air are sampled at constant rate of 0.9 to 1.3 m3 /min through the inlet of cyclone. By virtue of their momentum, particles greater than 10 microns are carried vertically upwards by the air flow and collected on a filter paper of 8 x 10 inch. technilcal specification flow rate 0.8 to 1.5 m3/min particle size up to 10 micron collected on filter and spm bigger than 10 micron collected in a separate collector cup blower continuous duty blower with brushless blower recommended filter gf/a(8” x 10”) for common use, epm 2000 for special research or equivalent time record 0 to 9999.99 hrs. Time totalizer records the running time in hours timer 24 hr programmable timer power requirement 220 volts, single phase ac sle-rds104 (nl) sharper cut off d50 system at 10 microns to separate coarser particles (> 10 microns) from air stream bfore filtering it on the glass micro fibre filter. special features 1 low noise operations. 2 brushless blower. 3 portable for easy transportation. 4 controlled flow. 5 spm of particle size less than 100 microns. 6 rspm of particle size less than 10 microns. 7 brush less & noise less blower without any belt. principle suspended particles in the air are sampled at 3 constant sampling rates of 0.9 to 1.4 m /min through the inlet of cyclone. By virtue of their momentum, particle greater than 10 microns are carried vertically upward by the air flow and collected on a filter paper of 8 x 10 inch. While coarse dust is collected in a cup placed under the cyclone. technical specification flow rate 0.9 to 1.4 m /min particle size up to 10 micron collected on filter and spm bigger than 10 micron collected in a separate collector cup under the cyclone accuracy + 2% of fsd blower continuous duty blower with noiseless & brushless without belt recommended filter gf/a (8” x 10”) for common use, epm 2000 for special research or equivalent time record 0 to 9999.99 hrs. Time totalizer records the running time in hours timer 24 hr programmable timer power requirement 220 volts, single phase, 50 hz ac main supply.
Respirable Dust Sampler
Get Price Quote
We are offering respirable dust sampler. Apm 460 bl is respirable dust sampler also called as pm 10 sampler is used for monitoring pm 10 in ambient air.
Respirable Dust Sampler
Get Price Quote
Suspended Particles Matter( SPM) which is defined as particles less that 100 microns & Respirable Suspended Particle less than 10 microns have emerged as the most critical among all the criteria air pollutants & is caused by number of sources like Large, medium & small-scale industries, Road dust construction activities, house hold fuel cooking, waste burning, vehicular emissions etc.