solar pv railway signal
Solar Power Plants
Module Wattage 0.5 KWp to 500 KWp Battery Bank Voltage Options 24, 48, 96, 110, 120, 240 Volts DC. Or 220 / 240 Volts 50 Hz A/C Type of Battery Bank Consisting of 2/6 Volts cells of Positive tubular plate type conforming to IS 1651 or any other type as per customer's requirements PCU (Inverter+Charge Controller) As per customer requirements Distribution Underground / overhead as per customer requirements Earthing Single conductor (positive or negative) Earthing or centre tap Earthing Loads As per customer's requirements
...moresolar power conditioning units
These conform to the requirements of MNRE for performance, environmental and IP Testing. These can be applied to systems for MNRE’s NABARD and allied schemes as well as remote site applications where grid may or may not be available.Inverter Overload Grid Chg. Inverter On PV Chg. Battery Voltage Low Inverter Short circuit Over Load Battery under over voltage No Load Shutdown
...moreSolar Lanterns
PROVISIONS On-Off Switch Fuse LED indications for :- battery deep discharge (Load disconnect) battery overcharge (Charging disconnect) (optional) Charging in process Plug and socket for the connection of PV module to the lantern for charging Solder free installation GENERAL SPECIFICATIONS
...moreSolar Lamp
On-Off Switch,Fuse,battery deep discharge (Load disconnect),battery overcharge (Charging disconnect) (optional),Charging in process,Plug and socket for the connection of PV module to the lantern for charging,Solder free installation.
...moreSolar Controller
Chg. Topology,PWM Type (µc based,System Voltage,12V24V automatic,Max solar current or load current,5A 10A,15A 20,Boost voltage 14.4V28.8V (+-0.2V)
...moreSolar CFL Street Light
offers a wide range of Solar PV Street Lighting Systems with standard and custom built versions. The Standard model generally conforms to MNES specification.600 lumens (nominal) for each Luminaire of CFL 09W lamp
...morePower Conditioner
PCUs are designed for small Solar Power Applications. These conform to the requirements of MNRE for performance, environmental and IP Testing. These can be applied to systems for MNRE’s NABARD and allied schemes as well as remote site applications where grid may or may not be available.
...moreOthers Power Conditioning Units
RITIKA PCUs are designed for small Solar Power Applications. These conform to the requirements of MNRE for performance, environmental and IP Testing. These can be applied to systems for MNRE’s NABARD and allied schemes as well as remote site applications where grid may or may not be available. FEATURES Micro Controller based Technology. PWM (Pulse Width Modulation) design. Grid Charger & Inverter with Bi-Directional operation. Pure Sine-wave output with low THD. Short Circuit Protection. No Load Shutdown. Battery Deep Discharge Protection. Reverse Polarity Protection. Under/Over Output Voltage Protection. Battery Over-Charging Protection. High efficiency DC – DC power conversion. Fast Changeover time. Data Logging (Optional) LED/LCD Display for metering, I/P & O/P Parameters.
...moreSolar PV Interfaces
RITIKA Systems Solar PV Interfaces are designed for customers who have already invested in a domestic inverter and battery set, and now desire to switch to solar power. They may use this system to integrate solar PV charging in a simple and cost efficient manner. Being an-add on to the existing domestic inverter, this offers a very cost efficient way of converting an existing domestic inverter (already owned by the customer) into Solar Power Conditioning Unit (Solar Inverter + Battery Charge Controller). Interface can automatically sense 12V/24V system and work accordingly. OBJECTIVE:- To promote Solar Energy and thus contributing to the environment. To make Solar Energy more affordable. To develop and manufacture an easy to install/maintain system that works with existing domestic inverter/storage batteries. To monitor battery charge levels at all times. To give preference to Solar PV charging. This helps in reducing AC grid electricity units consumed by the customer. CONNECTION DIAGRAM
...moreSolar Charge Controllers
Solar Garden Lights
RSPL offers a wide range of Solar Garden Lights & Lamp Post with standard and custom built versions.
...moreLED Solar Street Lighting Systems
Led Solar Lanterns
PROVISIONS On-Off Switch Fuse LED indications for :- battery deep discharge (Load disconnect) battery overcharge (Charging disconnect) (optional) Charging in process Plug and socket for the connection of PV module to the lantern for charging Solder free installation.
Weight : 2.5 to 4 Kg
...moreLED Solar Home Lighting Systems
Lcd Inverter
Operation Mode,PCU must be designed to work in 1. Stand Alone Mode 2. Hybrid Mode 3. OFF-LINE Mode (500VA, 1 KVA & 2KVA),Indications Inverter Overload Grid Chg. Inverter On PV Chg. Battery Voltage Low Inverter Short circuit Over Load Battery under over voltage No Load Shutdown
...morecompact fluorescent
Lantern Housing material,AluminiumABSas required,Chimney Material Acrylic Polycarbonate,Lamp 57 Watts compact fluorescent lamp in four pintwo pins version,SPV Module 81012 Wp module depending upon the model,Battery Sealed Maintenance Free Battery of Absorbed Electrolyte type
...moreCFL Solar Street Lighting Systems
RSPL offers a wide range of Solar PV Street Lighting Systems with standard and custom built versions. The Standard model generally conforms to MNES specification.
...moreCFL Solar Lighting Systems
solar pv street lighting
solar electric luminaries
electronic charge controllers
Battery Chargers
solar photovoltaic power plants
Be first to Rate
Rate ThisOpening Hours