Soil Analyzer Kit Dealers in Delhi

(11 products available)
  • Water Analysis Kit, Soil Analysis Kit

    Water Analysis Kit, Soil Analysis Kit

    13,000 Per Piece

    1 Piece (MOQ)

    • Country of Origin: India
    • Packaging Type: Box
    • Usage/Application: For Water And Soil Testing
    • Type: Portable
    • Material: Plastic
    • Range: 0 - 14 pH
    • Model: 361R
    more..
  • Water and Soil Analysis Kit

    Water and Soil Analysis Kit

    Get Price Quote

    Water and Soil Analysis Kit that we manufacture, export and supply is very easy to operate by simply putting the F2 switch to standby position and switch on the instrument. The display will indicate 000 at the start. It is advisable to clean the membrane with a soft tissue paper after every use. Our Water and Soil Analysis Kit is appreciated for its accuracy in measurements and portable size. It is available in an easy-to-use kit.   pH Measurements : Put the function switch to pH / Orp mode. Wash the electrode with distilled water and dry it with filter water Connect the electrode BNC plug at the input socket Put the combination pH electrode in buffer solution 7.00 pH. Set the Temp. Knob to the Temp. Of the buffer solution. Now move the switch F2 to pH mode. Read the display value, adjust it with Cal control to 7.00 pH value. Again Move the selector switch F2 to Stand by mode. Take out the electrode from 7.00 pH buffer and wash it with distilled water and dry it with filter paper. Put the electrode in 4.00 pH solution. Set this value to 4.00 pH by setting Slope control. The instruments is ready to take measurements.   O.R.P. Measurements : Put the function Switch F1 to pH/ORP mode. Rinse the CRP electrode with distilled water and dry it with filter paper. Connect the ORP electrode BNC plug at Input socket. Take 0.00 mV buffer solution freshly prepared and calibrate with Cal knob. The instruments is calibrated and ready for taking ORP measurement of any other solution.   Conductivity Measurements : Put the function switch at Cell Const Position Adjust the display to the cell constant value marked on the conductivity cell supplied with the instrument. Now move the switch to the COND. Position Put the range switch at appropriate positions so that best possible resolution is obtained.   TDS Measurements : Put the function switch at TDS Position Clean the conductivity cell, dry it and connect in cond/TDS input socket. Adjust the display to cell constant value marked on conductivity cell by cell const, knob and function switch at Cell const position. Dip the cond. Cell in the unknown solution whose TDS value to be measured. Put the range switch at appropriate PPM/PPT position, so it best possible resolution is obtained.   Cell Constant Measurement : It is recommended that cell constant of the conductivity cell must checked off and on. This can be done as follows : Dip the conductivity cell in a solution of known conductivity. (1408µmhos) Keep the function switch Fat Cond position. Adjust the display to the value of known solution by rotating CE Constant Knob. Bring function switch F to Cell const. Position. The display will indicate the cell constant of the conductivity cell.   D.O. Measurements is done by following steps : D.O. Probe Assembly D.O. Probe consist of a silver and gold electrode cells, an electrolyte tube with thering.   The following procedure may be followed for assembly or D.O. Probe Be careful to handle its membrane. Fit the membrane on the lower part of the electrolyte tube. Fix the ring on the electrolyte tube covering the sides of the membrane. Fill Potassium chloride solution (7.5%) in the electrolyte tube to its top. Insert the electrode in the electrolyte tube and tightly screw it up. Now the probe is ready to use.   D.O. Operation : Put the function switch F1 to D.O. Mode and adjust the display to Co.o with Zero knob and insert the D.O. Probe in D.O. Sockets. Please keep colour code in consideration. Keep the Temp knob to the extreme left position and Cal Knob to extreme right position. Place the D.O. Probe in 2% sodium Sulphite solution. Allow the display to attain equilibrium. If the display does not read 000, set the zero knob to bring the display to read 000 by keeping the temp. Knob to actual temp. Of the solution. Calibrate knob should be at extreme right position. Now Calibrate the instrument with known value of D.O. Solution Take 250 ml. Flash and fill 2/3 of it with distilled water. Stopper the flash and shake it for 30 seconds. Remove the stopper back and siri the water back and repeat the procedure 4 times. Measure the temp. Of the water and set the temp. Knob at temp of water in the flask. Hold do probe in the flash and agitate the water. Note the reading of the display and check the value with that of the table below for given temperature. If necessary adjust the meter reading with CaL knob.   Note : Please refer to the saturation values of the dissolved Oxygen in distilled water as given in Table 1. it shows the values for dissolved oxygen which will be obtained when shaking the distilled water at different temp. In the air. Now the instruments is ready to take measurements of D.O. Value of any unknown solution   Caution : Since the measurement is based on the diffusion process, the agitation of the solution is must. Hand shaking of the solution may not give accurate readings, magnetic stirrer is recommended for this purpose. Movement of the solution should be about 2ft/sec for accurate measurement. BOD bottle is recommended as a container for measurement of sample solution in the laboratory. Because DO probe tight fits in BOD bottle and no atmospheric oxygen may dissolve during measurement.   Maintenance of D.O. Probe : Do not touch the silver electrode of the probe. The Membrane must not have any pin hole, puncture. The DO reading will be erratic at constant DO concentration and temperature, if the membrane has a puncture. Any accumulation of organic matter on the membrane will effect the Cal. It is advisable to clean the membrane with a soft tissue paper after use.

    more..
  • Best Deals from Soil Analyzer Kit

  • Water and Soil Analysis Kit

    Water and Soil Analysis Kit

    Get Price Quote

    Water and soil analysis kit is based on advance electronic technology for water analysis, pollution control, laboratory analysis, soil testing etc. The complete unit is housed in a briefcase to work on battery rechargeable cum mains. Unit is supplied without O.R.P. electrode with instruction manual. (a) Six Parameters :(pH, Conductivity, TDS, ORP, DO and Temp) (b) Five Parameters : (pH, Conductivity, , ORP, DO and Temp) (c) Seven Parameters : (pH, Conductivity, TDS, Salinity, DO, Temp. and Turbidity)

    more..
  • Water and Soil Analysis Kit

    Water and Soil Analysis Kit

    Get Price Quote

    A great portable equipment for measuring pH, mV(ORP), Conductivity, temperature, TDS, Dissolved Oxygen (DO), Salinity and turbidity.pH Range: 0 - 14 pH Resolution: 0.01pH Accuracy: ±0.01 pH ±1 digit Temp Compensation: 0-100°C (Manual) Calibration Manual mV (ORP) Range: 0 to ±1999mV Resolution: 1mV Accuracy: ±1mV ±1 digit Conductivity (EC) Range: 0 to 1000 mmho in 5 ranges Resolution: 0.01 umho Accuracy: ±0.5% FS±1 digit Cell Constant: Adjustable (0.4 to 1.5) Reference Temp.: Adjustable (25°C) Temperature: 0 to 100° C Resolution: 0.1° C Accuracy: ±0.5° C ± 1 digit TDS Range: 0 to 10,000 mg/litre Resolution: 10 mgs/litre Accuracy: ±1% FS ±1 digit DISSOLVED OXYGEN (O2) Range: 0 to 20 ppm Resolution: 0.1 ppm Accuracy: ±0.2 ppm ±1 digit Temp. Comp.: 10° C to 50° C (Manual) DO Sensor Gold/Silver Amperometric Calibration Manual SALINITY Range: 0 to 40 ppt Resolution: 0.1 ppt Accuracy: ±0.5% ±1 digit TURBIDITY Range: 0 - 100 JTU Resolution: 1 JTU Accuracy: ±3% FS ±1 digit Sample size: 30 mm glass tube Light: 6.8 V Tungston lamp Detector: Photodiode GENERAL Display 3 1/2 digit (LCD) Operation Temp. 0° to 50° C Housing Materials ABS briefcase Power Supply 230 V ±10%, 50 Hz AC, 9V Battery (Dry cell) Standard Accessories Include the following:pH electrode, Conductivity/TDS/Salinity probe , Temp. probe, DO probe, Set of DO membranes, Test tube for turbidity (3)

    more..
  • Water and Soil Analysis Kit

    Water and Soil Analysis Kit

    Get Price Quote

    A great portable equipment for measuring pH, mV(ORP), Conductivity, temperature, TDS, Dissolved Oxygen (DO), Salinity and turbidity.pH Range: 0 - 14 pH Resolution: 0.01pH Accuracy: ±0.01 pH ±1 digit Temp Compensation: 0-100°C (Manual) Calibration Manual mV (ORP) Range: 0 to ±1999mV Resolution: 1mV Accuracy: ±1mV ±1 digit Conductivity (EC) Range: 0 to 1000 mmho in 5 ranges Resolution: 0.01 umho Accuracy: ±0.5% FS±1 digit Cell Constant: Adjustable (0.4 to 1.5) Reference Temp.: Adjustable (25°C) Temperature: 0 to 100° C Resolution: 0.1° C Accuracy: ±0.5° C ± 1 digit TDS Range: 0 to 10,000 mg/litre Resolution: 10 mgs/litre Accuracy: ±1% FS ±1 digit DISSOLVED OXYGEN (O2) Range: 0 to 20 ppm Resolution: 0.1 ppm Accuracy: ±0.2 ppm ±1 digit Temp. Comp.: 10° C to 50° C (Manual) DO Sensor Gold/Silver Amperometric Calibration Manual SALINITY Range: 0 to 40 ppt Resolution: 0.1 ppt Accuracy: ±0.5% ±1 digit TURBIDITY Range: 0 - 100 JTU Resolution: 1 JTU Accuracy: ±3% FS ±1 digit Sample size: 30 mm glass tube Light: 6.8 V Tungston lamp Detector: Photodiode GENERAL Display 3 1/2 digit (LCD) Operation Temp. 0° to 50° C Housing Materials ABS briefcase Power Supply 230 V ±10%, 50 Hz AC, 9V Battery (Dry cell) Standard Accessories Include the following:pH electrode, Conductivity/TDS/Salinity probe , Temp. probe, DO probe, Set of DO membranes, Test tube for turbidity (3)

    more..
  • Soil Analysis Kit

    Soil Analysis Kit

    Get Price Quote

    Digital water & soil analysis kit npc 361d: lcd display for ph,orp,tds,salinity, conductivity.dissolved oxygen & temperature . Main cum battery operation with inbuilt abs briefcase.complete with standard accessories.

    more..
  • Soil Analysis Kit

    Soil Analysis Kit

    Get Price Quote

    Water and Soil Analysis Kit (1072) • Measures pH, Conductivity,TDS, DO, Salinity, mV & Temperature • Turbidity measurement • Turbidity measurement • Available in 3 ½ digit LCD display

    more..
  • Soil Analysis Kit

    Soil Analysis Kit

    Get Price Quote

    Soil Analysis Kit, Air Permeability Apparatus, Vicat Needle Apparatus

    more..
  • Water and Soil Analysis Kit

    Get Price Quote

    Water and Soil Analysis Kit, Humidifier, Dehumidifier, Moisture Analyzer

    more..
  • soil analysis kits

    Get Price Quote

    soil analysis kits, biotech instruments, Water Testing Kits

    more..
  • Water & Soil Testing Analysis Kits

    Get Price Quote

    Water & Soil Testing Analysis Kits, Water Still, geared stirrer, rotamantles

    more..
Filter by Locality
top