  • Blood Roller Mixer

    Blood Roller Mixer

    Get Price Quote

    5 Piece (MOQ)

    • Country of Origin: India
    • Voltage: 220 / 230 V
    • Dimensions: 455 x 265 x 120 mm
    • Frequency: 50 Hz
    • Maximum Load: 5 Kg
    • Rolling Speed: 10 - 30 RPM
    • Body Material: MS Coated

    Description: The BRADLEYVACUTUBE Blood Roller Mixer Tube Mixer, available in a convenient pack of 1 piece, redefines sample mixing with precision and reliability. Engineered for optimal performance in blood sample preparation, this mixer ensures thorough and consistent mixing, essential for accurate analytical results in clinical and research laboratories. Key Features: Variable Speed Control: The Blood Roller Mixer Tube Mixer by BRADLEYVACUTUBE features variable speed control, allowing users to tailor the mixing speed to the specific requirements of their applications. This adaptability is particularly valuable for diverse blood sample preparations, ensuring gentle yet effective mixing. Tube Capacity and Compatibility: Designed to accommodate a single tube, this mixer caters to the specific needs of laboratories requiring focused mixing of individual blood samples. The adjustable rollers ensure compatibility with various tube sizes, providing versatility in sample processing. Quiet and Smooth Operation: The mixer operates with minimal noise, creating a conducive laboratory environment. Its smooth and quiet operation is achieved through precision engineering, minimizing disturbance during critical sample processing procedures. Benefits: Uniform Sample Homogenization: The variable speed control and optimized roller design of the Blood Roller Mixer ensure uniform sample homogenization. This is crucial for obtaining consistent results in hematological analyses, facilitating accurate and reproducible data. Time-Efficient Processing: With its single-tube design and efficient mixing capabilities, the BRADLEYVACUTUBE Blood Roller Mixer expedites sample preparation workflows. Researchers can save valuable time without compromising the quality of sample homogenization, enhancing overall laboratory efficiency. Compact and User-Friendly: The compact design of the mixer allows for easy integration into laboratory spaces of varying sizes. Its user-friendly interface ensures straightforward operation, making it an accessible tool for both experienced researchers and laboratory professionals.  

    more..
  • Automatic Leak Test Apparatus

    Automatic Leak Test Apparatus

    Get Price Quote

    Features : Fully micro controlled operation, first time in india Simultaneous display of time and vacuum on display module Start delay / retention / vacuum hold time can be set as per requirement from 0-999 seconds 16 x 2 cm large size numerical from desiccators at the end of the test Automatic release of vacuum from desiccators at the end of the test Meet USP 28 packing practice specification Vacuum & time can be programmed Set required vacuum and countdown hold time Built in portable, maintenance free, oil free vacuum pump

    more..
  • Best Deals from Soil Testing Equipment

  • Water Analysis Kit, Soil Analysis Kit

    Water Analysis Kit, Soil Analysis Kit

    13,000 Per Piece

    1 Piece (MOQ)

    • Country of Origin: India
    • Packaging Type: Box
    • Usage/Application: For Water And Soil Testing
    • Type: Portable
    • Material: Plastic
    • Range: 0 - 14 pH
    • Model: 361R
    more..
  • leak test apparatus

    leak test apparatus

    28,000 Per Piece

    2 Piece(s) (MOQ)

    • Brand Name: Micronvac
    • Condition: New
    • Warranty: 1 Year
    • Material: Stainless Steel
    • Application: Leak Testing
    • Voltage (V): 220
    • Vacuum Level (mm): 760mmhg
    • Display: Digital
    • Speed (RPM): 1440rpm
    more..
  • Water and Soil Analysis Kit

    Water and Soil Analysis Kit

    Get Price Quote

    Water and Soil Analysis Kit that we manufacture, export and supply is very easy to operate by simply putting the F2 switch to standby position and switch on the instrument. The display will indicate 000 at the start. It is advisable to clean the membrane with a soft tissue paper after every use. Our Water and Soil Analysis Kit is appreciated for its accuracy in measurements and portable size. It is available in an easy-to-use kit.   pH Measurements : Put the function switch to pH / Orp mode. Wash the electrode with distilled water and dry it with filter water Connect the electrode BNC plug at the input socket Put the combination pH electrode in buffer solution 7.00 pH. Set the Temp. Knob to the Temp. Of the buffer solution. Now move the switch F2 to pH mode. Read the display value, adjust it with Cal control to 7.00 pH value. Again Move the selector switch F2 to Stand by mode. Take out the electrode from 7.00 pH buffer and wash it with distilled water and dry it with filter paper. Put the electrode in 4.00 pH solution. Set this value to 4.00 pH by setting Slope control. The instruments is ready to take measurements.   O.R.P. Measurements : Put the function Switch F1 to pH/ORP mode. Rinse the CRP electrode with distilled water and dry it with filter paper. Connect the ORP electrode BNC plug at Input socket. Take 0.00 mV buffer solution freshly prepared and calibrate with Cal knob. The instruments is calibrated and ready for taking ORP measurement of any other solution.   Conductivity Measurements : Put the function switch at Cell Const Position Adjust the display to the cell constant value marked on the conductivity cell supplied with the instrument. Now move the switch to the COND. Position Put the range switch at appropriate positions so that best possible resolution is obtained.   TDS Measurements : Put the function switch at TDS Position Clean the conductivity cell, dry it and connect in cond/TDS input socket. Adjust the display to cell constant value marked on conductivity cell by cell const, knob and function switch at Cell const position. Dip the cond. Cell in the unknown solution whose TDS value to be measured. Put the range switch at appropriate PPM/PPT position, so it best possible resolution is obtained.   Cell Constant Measurement : It is recommended that cell constant of the conductivity cell must checked off and on. This can be done as follows : Dip the conductivity cell in a solution of known conductivity. (1408µmhos) Keep the function switch Fat Cond position. Adjust the display to the value of known solution by rotating CE Constant Knob. Bring function switch F to Cell const. Position. The display will indicate the cell constant of the conductivity cell.   D.O. Measurements is done by following steps : D.O. Probe Assembly D.O. Probe consist of a silver and gold electrode cells, an electrolyte tube with thering.   The following procedure may be followed for assembly or D.O. Probe Be careful to handle its membrane. Fit the membrane on the lower part of the electrolyte tube. Fix the ring on the electrolyte tube covering the sides of the membrane. Fill Potassium chloride solution (7.5%) in the electrolyte tube to its top. Insert the electrode in the electrolyte tube and tightly screw it up. Now the probe is ready to use.   D.O. Operation : Put the function switch F1 to D.O. Mode and adjust the display to Co.o with Zero knob and insert the D.O. Probe in D.O. Sockets. Please keep colour code in consideration. Keep the Temp knob to the extreme left position and Cal Knob to extreme right position. Place the D.O. Probe in 2% sodium Sulphite solution. Allow the display to attain equilibrium. If the display does not read 000, set the zero knob to bring the display to read 000 by keeping the temp. Knob to actual temp. Of the solution. Calibrate knob should be at extreme right position. Now Calibrate the instrument with known value of D.O. Solution Take 250 ml. Flash and fill 2/3 of it with distilled water. Stopper the flash and shake it for 30 seconds. Remove the stopper back and siri the water back and repeat the procedure 4 times. Measure the temp. Of the water and set the temp. Knob at temp of water in the flask. Hold do probe in the flash and agitate the water. Note the reading of the display and check the value with that of the table below for given temperature. If necessary adjust the meter reading with CaL knob.   Note : Please refer to the saturation values of the dissolved Oxygen in distilled water as given in Table 1. it shows the values for dissolved oxygen which will be obtained when shaking the distilled water at different temp. In the air. Now the instruments is ready to take measurements of D.O. Value of any unknown solution   Caution : Since the measurement is based on the diffusion process, the agitation of the solution is must. Hand shaking of the solution may not give accurate readings, magnetic stirrer is recommended for this purpose. Movement of the solution should be about 2ft/sec for accurate measurement. BOD bottle is recommended as a container for measurement of sample solution in the laboratory. Because DO probe tight fits in BOD bottle and no atmospheric oxygen may dissolve during measurement.   Maintenance of D.O. Probe : Do not touch the silver electrode of the probe. The Membrane must not have any pin hole, puncture. The DO reading will be erratic at constant DO concentration and temperature, if the membrane has a puncture. Any accumulation of organic matter on the membrane will effect the Cal. It is advisable to clean the membrane with a soft tissue paper after use.

    more..
  • Dissolution Test Apparatus

    Dissolution Test Apparatus

    250,000 - 260,000 Per Piece

    1 Piece (MOQ)

    • Material: Mild Steel
    • Certification: CE Certified, ISO 9001:2008
    • Application: Dissolution Testing
    • Color: Grey, Light White, Off White
    • Voltage: 220V
    • Condition: New
    • Dimension: 340mmx330mmx475mm
    • Power: 1KV
    • Driven Type: Electric
    • Phase: Single Phase
    • Warranty: 1yrs
    • Temperature: 0-50°C
    more..
  • Jar Testing Apparatus

    Jar Testing Apparatus

    9,000 Per Piece

    1 Piece (MOQ)

    • Material: Stainless Steel
    • Voltage: 220 V
    • Brand: Precious Techno Engineering
    • Automation Grade: Automatic
    • Power Source: Electric
    • Frequency: 50/60 hz
    • Speed: 20 to 180 RPM
    • Weight: 20 kg
    • Motor Power: 20 HP
    more..
  • Cold Bend Test Apparatus (as per IS)

    Cold Bend Test Apparatus (as per IS)

    Get Price Quote

    • Model: : SSI 506 CBIS (Cold Bend Test apparatus as per IS)
    • Stand Construction: :  Made of MS, hard chromed / Painted
    • Mandrels: :  4 Mandrels of 5,10,20,30 mm Dia
    • Sample Rotation: :  Manual
    •  :  
    • Delivery : 2 to 3 weeks: Packing : One Wooden Box

    Model Number: SSI 506 CBIS Standard Number: IS :10810 Pt 20   Cracks and deformation occur when the material is bend or wound under cold conditions. The apparatus is deigned to wound the cable samples on standardized mandrels under cold conditions.   Instrument Principle The instrument is designed to test the flexibility or bending quality of cable under low temperatures. The cable is wrapped on the mandrel and is subjected to  very low temperatures. The cable should not develop cracks or cuts after the cable is unwrapped form the mandrel. The test is applicable for specimen of diameter up to and including 12.5 mm, above which the test is considered impracticable. Standard The instrument conforms to IS 10810 Pt 21 Instrument   The Instruments consist of      Metal Mandrel.      Metal Frame for mandrel attachment The sample is cooled in the cold chamber for specified time and then wound on the mandrel. The sample is then checked for any cracks or scales visible to the unaided eye.

    more..
  • Tablet Friability Apparatus

    Tablet Friability Apparatus

    Get Price Quote

    • Type: Tablet Friability Test Apparatus
    • Application: Friability Testing
    • Color: Brown, Light White, Off White, Silver
    • Voltage: 110V, 220V, 380V, 440V
    • Condition: New, Used
    • Power: 1KV, 2KV, 500W, 750W
    • Driven Type: Electric, Hydraulic, Mechanical, Pneumatic
    • Warranty: 1yrs, 2yrs
    • Material: Mild Steel, Stainless Steel
    • Phase: Double Phase, Single Phase, Triple Phase
    • Temperature: 0-50°C, 100-200°C, 200-400°C, 50-100°C
    more..
  • Soil Testing Equipment

    Soil Testing Equipment

    Get Price Quote

    • Features: Easy installation, Dimensional accuracy, Fine finish, Smooth operation, Sturdy design
    more..
  • Tablet Friability Apparatus

    Tablet Friability Apparatus

    66,000 Per Piece

    • Voltage: 220V AC
    • Type: Tablet Testing
    • Model: EF2W
    • Display: LCD
    • No. Of Drums: One / Two
    • Interfaces: RS232
    • Number Of Revolutions: 20 to 50 RPM
    • I deal in: New and Second Hand
    more..
  • Aggregate Impact Testing Apparatus

    Get Price Quote

    Aggregate Impact Testing Apparatus, Rockwell Hardness Testing Machine

    more..