Model 660 Air Velocity Monitor
Get Price Quote
model 660 air velocity monitor continuously measures fume hood airflow model 660 air velocity monitors are a practical, affordable way to continuously monitor for safe air flows through laboratory fume hoods. They are typically installed in the fume hood side fascia and connected to the interior sidewall via 1-18" flexible tubing. As the exhaust fan draws air through the device, a sensitive constant temperature thermistor measures flow and lights a green (normal), yellow (high) or red (low) led. An audible alarm also warns of low flow and requires manual resetting. Mounting holes fit standard single gang electrical box. product applications : warns user if insufficient fume hood face velocity is encountered. specifications service:air and non-combustible, non-corrosive gases. high setpoint range:0-275 fpm (0-1.397 m/s). low setpoint range:0-150 fpm (0-.792 m/s). repeatability:±7% of full span, 0-50 and 150-275 fpm; ±5% of full span, 50-150 fpm. compensated temperature range:50 to 90°f (10 to 32.2°c). operating temperature range:32 to 120°f (0 to 48.9°c). power supply:24 vac, 3 watts maximum. response time:6-10 seconds. warm-up time:3-5 minutes (no flow). audible alarm:75 db between 3-10 feet. weight:3 oz (85 g). mounting hardware:(2) #6 x 1" sheet metal screws, (2) 6-32 x 7/8" machine screws. related products model vt120 integral vane thermo-anemometer model vt120 integral vane thermo-anemometer model 480 vaneometer™ swing vane anemometer model 480 vaneometer™ swing vane anemometer model vt-200 vane thermo-anemometer model vt-200 vane thermo-anemometer
Model 660 Air Velocity Monitor
Get Price Quote
Best Deals from Velocity Monitor
Digital Velocity Monitor
Get Price Quote
We are offering digital velocity monitor is designed to determine velocity of air/flue gas in duct /pipe/chimney. Where determination of the rate of flow inside a chimney is of interest. This instrument can be conveniently used to measure the total quantity/volume of emissions. sle – dvm174 is provided with a digital pyrometer and thermocouple for measurement of temperature. A digital pressure cell is incorporated in a hand held unit for the measurement of pressure in mm of h2o directly along with a pitot tube. The pitot tube has been provided with an extendable arm for easy transportation. features : • compact hand held velocity monitor • digital pressure cell in place of cumbersome liquid manometer • highly accurate & reliable readings • carrying case • measures velocity as high as 100 m/s technical specifications stack temperature range: ambient to 600 ⁰ c read on a digital pyrometer. stack velocity range: 2 to 1 00 m/sec. thermocouple: thermocouple sensor in ss 304 casing, length of insertion: 0.6m with 2m long cable manometer: digital with 0-1300mm of h, o range with 0.1mm least count. pitot tube: modified calibrated s-type pitot tube fabricated from ss 304, 0.6m length with extension of 0.6m. list of components sle – dvm174 : instrument panel consisting of digital pyrometer & digital manometer, pitot tube, thermocouple, connecting pipe, carrying case etc.