Syringe Pump
Get Price Quote
Technical Specifications : Injection Rate : 50(60)ml Syringe: 0.1 - 999.9 ml/h (0.1ml/h step) 1000 - 1500ml/h (1ml/h step) 30ml Syringe: 0.1 - 900 ml/h (0.1ml/h step) 20ml Syringe: 0.1 - 600 ml/h (0.1ml/h step) 10ml Syringe: 0.1 - 300 ml/h (0.1ml/h step) 5ml syringe: 0.1 - 100ml/h (0.1ml/h step) Rate Accuracy : Within ±3% (after correct calibration) Mechanical Accuracy : Within ±2% Purge Rate : 50(60)ml Syringe: 1500ml/h 30ml Syringe: 900ml/h 20ml Syringe: 600ml/h 10ml Syringe: 300ml/h 5ml Syringe: 100ml/h Bolus Rate : 50(60)ml Syringe: 1200ml/h 30ml Syringe: 720ml/h 20ml Syringe: 480ml/h 10ml Syringe: 240ml/h 5ml Syringe: 100ml/h Occlusion : High: 800mmHg±200mmHg Medium: 500mmHg±100mmHg Low: 300mmHg±100mmHg Volume Limit / Total Injection : 0.1 - 999.9ml (0.1ml step) KVO Speed : 0.1 ~ 5ml/h (0.1ml/h step). KVO Rate : 1ml/h Power Source : 100-240VAC, 50/60Hz. Power Consumption : 30VA. Dimension : 280(L)x210(W)x130mm(H). Net Weight : 2.2Kg. Winning Advantages: HD LCD Dynamic Displays working status. High Capacity Words. User Friendly Interface. Alarm : Audible / Visual for Occlusion, Empty, Near Empty, Low Battery, End of Injection, Syringe Loose, Wrong Settings. Preset Solution Volume greatly reduces nurses workload. Working Modes : Rate mode, Time Volume mode, Dosage Weight mode. Freely Stackable upto a maximum of 8 to provide multiple solutions for wide range of clinical applications. One - key Operation makes setup easy and simple. Automatically records the settings of last injection. Syringe plunger grabble detector, operable with one hand in a No - Germ Environment. DC12V car charge. Internal Rechargeable Li Battery ≥1, 600mAh 4 hours backup. KJ-810D stores 2000 Injection records. Drug Library Available.
Syringe Infusion Pump
62,000 Per Pound
Best Deals from Veterinary Syringe
PERFUSOR COMPACT
Get Price Quote
Features: All standard syringes of 10ml\20ml\50ml are compatible. The machine diagnoses the syringe size automatically, and with a simple syringe specification setting, the syringe pump can guarantee an accurate and safe injection. Unique function of bedside injection supervision which makes patients and their relatives as well as nurses more assured. Excellent injection function and operation. Even small-volume injection is accurate. Double CPU system ensures safe and reliable injection process. Driven by precision step motor, no pulsating waves shall occur during even low-rate injection. Accurate and sensitive pressure sensor detects occlusion pressure accurately. Alarms are given in case of malfunction or operation error and the machine stops operation automatically. Specifications: Feasible injection rate range:10ml:0.1-100ml/h 20ml:0.1-200ml/h 50ml:0.1-500ml/h Maximum power consumption: 25VA,running more than 5h after being fully charged. Injection increment: 0.1ml/h Injection accuracy: ±3% Bolus: The fastest rate of the size of syringe in use Displayed information: Rate, accumulated injection volume, Syringe size Battery capacity, Bed No., AC power indicator, Battery charge indicator. Accumulated injection volume: 0-999.9ml Alarm functions: Near, Over, OCCL., low battery, syringe installation error, control abnormal, machine malfunction Electrical safety: Comply with the requirement of GB9706.1-1995, EN60601-1and UL60601-1 EMC(Electromagnetic compatibility); Comply with the requirement EN60601-1-2,EN60601-2-24 Power supply: 50/60Hz AC100V-240V Maximum weight:
Syringe Infusion Pump
Get Price Quote
Small size, low weight and high technology, incorporated into a compact design. Stackable, with a built-in locking mechanism. Due to its high flexibility, changing tasks are simply and easily solved. Quick and simple mounting at the patient's bedside, via universal clamp. Integratable in fm anesthesia fm intensive workstations.
syring pump
Get Price Quote
syring pump, PATIENTS MONITOR 5PARA, Hospital Bedside Locker, Hospital Bed