22kV Package Substation
1,500,000 Per Piece
1 Piece(s) (MOQ)
Features : Self-contained package substation All the equipment packed in a separate compartment All compartments are individually accessible Individual Door Operated lamp for illumination purpose Benefits : Complete weather Proof solution Ready to position solution Four lifting eyes for ease of lifting Minimum site work The following equipment can be accommodate inside the panel : Air Circuit Breaker (ACB’s) Moulded case circuit breakers (MCCB’s) LV Fuse switches / Fuse ways Instrumentation and metering APFC Panel (optional)
315kVA Distribution Transformer
Get Price Quote
1 Piece (MOQ)
Best Deals from Distribution Transformer
7 Amp Charging Transformer
500 Per Piece
20 Piece (MOQ)
Outdoor Oil Cooled Current Transformer
15,000 Per Nos
50 Piece (MOQ)
oil immersed distribution transformers
Get Price Quote
1 Piece (MOQ)
Convection moves oil through the coil and core assembly ducts and around the coil. In small ratings, the oil is cooled by the tank's exterior, and in more significant ratings, by an air-cooled radiator. Outdoor oil-type transformers can be ground, pad, or pole-mounted. They perform well in a variety of applications, including transmission and distribution networks, renewable energy generation, and small industries. We are one of the prominent oil immersed distribution transformer manufacturers in India.
solar transformer
Get Price Quote
Compact Substation
Get Price Quote
We provide Compact Substation in the market that is highly efficient in feeding power. Made as per the set industrial standards by using quality well-tested material, this Compact Substation is high in performance. The compact size of the Substation acquires minimum space, due to which this can be installed at roof top of the building or construction sites. Details : Mounted on skid frame or channels, with lifting hooks or portable trolley Compartmentalized with suitable medium voltage, low voltage sections & transformer section with separate doors for each compartment The doors are secured with double point Godrej type closing device with flush-mounted handles for padlocking Available in outdoor/indoor type
400kVA 3-Phase Oil Cooled Distribution Transformer
200,000 - 400,000 Per Piece
1 Piece (MOQ)
Compact Substation
450,000 Per Piece
1 Piece (MOQ)
The Compact Sub-Station (CSS) is also known as Unitised Sub-Station (USS) or Packaged Sub-Station (PSS). The Compact Sub-Staton is a compact arrangement, which replaces conventional sub-station arrangement consisting of Load Break Switch / Vacuum Circuit Breaker, Transformer, Distribution.
500 kVA Oil Filled Transformer
575,000 - 1,045,000 Per Piece
1 Piece (MOQ)
Compact Substation - Css
Get Price Quote
1 Piece (MOQ)
We are offering compact substation - css. css is a prefabricated secondary substation with type-tested equipment and includes a distribution transformer, medium voltage switchgear, low-voltage switchboard, connections and associated equipment in a compact unit. The enclosure is typically divided into three sections or compartments – medium voltage switchgear, low voltage switchboard and distribution transformer. application- power secondary distribution rated operational voltage – 11kv 33kv type- indooroutdoor-oildry type power rating- up to 2.5 mva
mobile substations
Get Price Quote
We are manufacturers, & Exporters of COMPACT SUBSTATIONS / Mobile Substations. We manufacture these Mobile Substations of different capacity. We can customise these Substations as per the client's requirement and clients's design
Three Phase HT Current Transformer
Get Price Quote
Electrical Transformer
Get Price Quote
Single & Three Out Door Oil Cooled Voltage Transformer
Get Price Quote
1 Piece (MOQ)
Following are main factors for selecting Voltage Transformer. Service Voltage:System Voltage in which V.T is to be installed e.g. 11kv, 22kv, 33kv etc. Installation:Whether OUTDOOR or INDOOR Atmospheric Conditions:Such as condition of Pollution, Altitude, Ambient Temperature etc. Insulation Level:If insulation level other than associated with service voltage is required, it should be specifically mentioned. Rated Primary Voltage:Rated primary voltage is generally rated system voltage for unearthed type V.Ts. and rated system voltage divided by square root of three for earthed type V.Ts. The V.Ts. can be manufactured suitable for more than one system voltage. In such cases, different primary voltages required may be indicated. Rated Secondary Voltage:Standard Values of Secondary voltages are 110v or 110v/\13 depending on application of the secondary winding. V.Ts. with different secondary voltages other than those mentioned above can be manufactured and supplied. Voltage Factor:All V.Ts, are manufactured suitable for continuous voltage factor of 1.2. As per I.S. / L.E.C. Specifications, short time voltage factor is different for different earthing systems. Therefore appropriate system earthing conditions may be specified. Number of secondary windings. Their burdens & accuracy classes:Number of secondary windings, their burdens and accuracy classes are selected on the basis of application. Two types of classes are available, one for metering and other for protection. Unlike current transformers, accuracy of one winding is influenced by loading of other winding. Due to this reason burden of each winding should be correctly mentioned. Accuracy of V.T. is guaranteed at the secondary terminals of the V.T. The impedance of cable connecting secondary terminal to load (Relay or Meter) offers series drop in output voltage. This causes additional errors in secondary winding at the measuring end of cable and is proportional to the load on the secondary. Therefore, it is advisable to select separate metering and protection winding. Alternatively, single winding can be used for metering and protection if separate cables are used for connections. (Cable of 4 sq. mm. cross section offer 2% voltage drop at 100 metres distance will 100 VA burden for secondary voltage of 110v/A).
Power Distribution Transformer
100,000 - 600,000 Per piece
Electrical Transformer
Get Price Quote
We understand that the use of finest grade raw material brings forth high quality product line. In addition to this, we make sure that the material is sourced from the reliable places only. We have hired a team of professionals who take care of the entire lot and make sure that it remains protected from air, dust, water and other damaging factors. Power transformers : 11 kV to 500 kV Voltage Level 1 MVA to 1000 MVA Power Handling Capacity with ONAN and/or ONAF cooling Distribution transformers : 0.2 kV to 33 kV Voltage levels Single or Three phase 15 MVA up to 1 MVA Power Handling capacity Oil immersed Copper and Aluminium Wound Resin/Dry Type transformer Pole mount and ground mount Voltage and Current Transformers of any configuration required Reactors and Earthing resistors Power Capacitors and Capacitor Banks for Network Compensation
25kVA 3-Phase Oil Cooled Distribution Transformer
42,000 Per Piece
1 Piece (MOQ)
kirloskar unitised substation
89,500 Per Set
1 Set (MOQ)
We are counted among the top Kirloskar Unitised Substation Suppliers in india. Features : High performance Made from high quality raw materials Durable Availed at highly competitive prices Specifications : Range : 11 KV -1000 KVA It comprises of a single factory built substation package having Transformer, HT & LT controls all Housed in a single enclosure. Indoor and Outdoor versions are available with safety features and mandatory requirements The Unitised Package Substation(USS) is provided with the following : Free standing metal enclosure fabricated out of high quality sheet steel mounted on rigid base frame and painted with epoxy paint of suitable colour. Kirloskar Make Resin cast, dry type, naturally air cooled, step down Transformer of rated capacity copper double wound having delta primary and star secondary with neutral brought out and having no load voltage ratio of 11kv/433v, type tested at CPRI. The CRT will be provided with tap links on HV winding to vary the voltage by +/-5%. We can also offer OLTC for transformer rating upto 500 kVA on request. Scanner type winding temperature indicator with 3 nos. RTD to measure/protect the winding against the set temperature. Suitable rated Vacuum Circuit Breaker / SF6 Circuit Breaker Load Break/ RMU/ Switch with interlocked Earth switch/ Shunt trip coil & Aux. Contacts. Main HT fuses in case of LBS. Potential Transformer. Current Transformers. Voltmeter with selector switch. Space heater with thermostat. TOD meter (Optional) O/C&E/F relay (in case of VCB) LT ACB of suitable rating with built in overload and short circuit and shunt trip coil. LT MCCBs/ Switch Fuse units of suitable rating for feeder controls. Ammeter with selector switch. Indicating lamps.
3 Kva Three Phase Transformer For Servo Drive
15,800 Per Piece
1 Piece (MOQ)