Fresh Air Units
145,000 Per Piece
1 Piece(s) (MOQ)
treated fresh air unit
75,000 Per Piece
1 Piece (MOQ)
Best Deals from Air Treatment Units
Floor Mounted Tfa Unit
65,500 Per Piece
1 Piece (MOQ)
fresh air unit
Get Price Quote
1 Piece (MOQ)
fresh air unit
60,000 - 400,000 Per Piece
1 Piece (MOQ)
Discription :- Double skin Air washer fresh air cooling system with 25 mm thick puff insulated panel outer skin 6mm. Precoated sheet, inner sheet 6mm. Plain gi and fan size as per requirement make Amca certified blower with motor make ABB/CG squirrel cage IE2 electric s.s. 202/304 grade 20/22/24 gauge Tank, 200mm, think cooling pad submersible and monoblock type single phase pump 2" thik dry pad for saving drift water on fan section area aluminium wiremess filter with aluminium/ gi frame and taper lock pully balt complete package Rates:- as per requirement of CFM
Treated Fresh Air Units
160,000 Per Piece
ULTIMATE Efficient TFA. With VIRTUAL Sensors. Cools Heats Humidifies Dehumidifies. Adapts to Ever Changing Outdoor Conditions! Using '100% Outdoor Air' these TFAs include the BEST of Vapour Compression with Multi-Compressor Options and Ultimate Psychrometric Programming to deliver Super Efficient Pre-Engineered Package with Air Side Filtration from Pre to HEPA! Multi-Compressor Fan Blower - TFA Designs for Effciency & Redundancy! TFA with Hot Gas for Air Heating and Water Preheating [for Steam Humidification]! Sandwich Panel Construction TFA INCLUDING Pre 2 HEPA Filtration. TFA Capacity Range 500 to 5000 CFM for DBRH Down To 15 deg C 50% RH Efficient Multi-Blower TFA Design suitable for Clean Air + Room Pressurization at Lowest Energy!
air treatment units
Get Price Quote
MODULAR AIR HANDLING SYSTEMS, SHELL AND TUBE TYPE CHILLER & 
 CONDENSERS, CLEAN ROOMS FOR LAB AND 
 OPERATION THEATRES, HVAC & Refrigeration Engineering Design.
air treatment units
Get Price Quote
5 Piece (MOQ)
Systems Handled :- Air Conditioning spaces SALIENT FEATURES Air Treatment Units consists of a Cooling coil , Blower, Motor and starter all enclosed in Aluminium Housing for rectangular shaped ATUs and Axial fans in Circular ATUs. Heat Transfer is --- Ambient Air / Chilled Water Interchangeability achieved in Flow Directions (Inlet/Outlet), Chilled water(Left/Right) & Mounting Material of Construction is Cupro Nickel (90/10-70/30) Coils housed in Al Mg Alloy Housings with extruded frame sections
treated fresh air unit
600,000 - 900,000 Per
4 Set (MOQ)
Price will be discussed on call. Â We have 4 sets of TFA unit1 Set = TFA 30000 CFM, Negative pressure unit 17000 CFM, Ventilation Unit 4000 CFM Â Treated fresh air unit used in temporary hospitals for over 2 months. Seeking to sell these units as soon as possible. Full cash payment preferred other means can also be entertained.Â
fresh air unit
Get Price Quote
Features: Highly suitable for fresh air Specially designed for pharmaceutical Available with pre-filters
Fresh Air Units
Get Price Quote
Fresh Air Units Casing : Main frame of self supporting hollow extruded Aluminum profile. Single Skin & 25mm thick double skin CFC free PUF injected panel. Fans : Belt drive driven DIDWSISW, forward and backward curved construction and direct drive fan.
treated fresh air unit
Get Price Quote
Removes particles like PM2.5 and treats bacteria/viruses, No byproduct generated, Very low Power consumption, Safe, Tested and certified by international agencies.
Treated Fresh Air Units
Get Price Quote
Double skin casing with choices of GSS SS304 for inner skin & Pre-painted Powder coated for outer skin.Choice of Al, SS & Screw less Al profile is also available, Choice of heat recovery wheel plate type heat exchanger heat pipe is also available,Wide mix of components like Pre Fine Hepa Carbon filters, heating coils, wet deck pad, drift eliminators, electric heaters, sound attenuation section with sound attenuators, dehumidifiers, humidifiers, UV light, cold plasma units is available as optional,Compact units upto 8000 CFM in both ceiling suspended and floor mounted vertical units are available, Also available with anti microbial , anti fugal coating and high resistant coating .
Treated Fresh Air Units
25,000 Per Piece
We are offering Treated Fresh Air Units
Treated Fresh Air Units
Get Price Quote
Our company is reputed as one amidst the prime Manufacturers of Treated Fresh Air Units, based in India. Our Treated Fresh Air Units are designed to serve as ultimate solution for IEQ and Energy Saving in a single modular unit with option to add modules for cooling, heating, humidification, high efficiency filtration, mixing, sound attenuation, etc. The advance configurations make our Treated Fresh Air Units easy to operate and ensure excellent performance. Treated Fresh Air Units (TFA) are also sometimes referred to in the industry as Fresh Air Handing Untis FAHU, Fresh Air Units, Rooftop Units, Outdoor Air Handing Units OAHU, Energy Recovery Units or simply Air Handling Units. Advantages with new series DRI TFA Time tested Reliability : The DRI TFA . . . . FlexAir Series comes from plant having over 10 years' experience in making two stream systems.Casing Air Leakage : The casing air leakage is of prime importance in two tier systems i.e. systems with two streams with high latent difference between both. The FlexAir Series TFA from DRI is designed in accordance with European Standard for leakage Class B.Maintenance-free Reliable Operation : Assured problem free operations even under tough circumstances as a result of solid construction with tight sealing between supply and exhaust air ensures minimal leakage.Very Low Pressure Drops : All functions like coils, heat exchangers etc. are optimised to give lowest possible pressure drop in proportion to highest possible efficiency resulting in very low LCC. Easy to Maintain Fan Assembly Fan assembly slides out for servicing. Saves time and money !Reliable solid transmission construction saves belts and bearing High Quality Standardised Filters Deep folded bag filters with big filter areas and good sealingThe good tightness ensures clean air supply to the room is of high quality Uniquely Designed Connection System : The unique design makes it possible for the assembler to choose from two different ways of connection when he assembles the unit in the machine room. Best Technology in Casing Manufacturing : The DRI TFA is manufactured in accordance with the best technology in casing manufacturing. New Modular Design . . . More Model Options : The new design allows several functions to be placed in the same casing. The FlexAir series has a wider range to cover the flow range better making it possible for you to easily select the right unit with the lowest LCC. Molecular sieve coated Heat Wheels Almost no cross contaminationOver 80% energy recovery, both latent and sensible. Ideal for tropical climates where latent loads are 2-3 times the sensible loadTotal energy recovery, recovers both latent and sensible energySpecially, adjustable purge section rules out cross contamination of air stream (less than 0.04%)Special labyrinth sealing arrangement ensure no cross leakage of air stream between the supply and exhaust sectionMost advanced technologyCertified/ Tested in international labsWheels edges hardened to suit marine/ coastal application needsBest LCC (Life Cycle Cost) How does the DRI Treated Freah Air Unit work? The heart of the FlexAir Treated Fresh Air Unit is the EcoFresh desiccant coated energy recovery wheel, which slowly rotates between its two sections. In one section, the stale, conditioned air is passed through the wheel, and exhausted in the atmosphere. During this process, the wheel absorbs sensible and latent energy from the conditioned air, which is used to condition (cool / heat) the incoming fresh Air in the other section, during the second half of its rotation cycle. Thus, you can have more fresh Air at lower humidity levels and energy costs inside your conditioned space. Ideal For Hospitality – Hotels, Restaurants, Pubs, Bars, DiscothequesHealthcare – Hospitals, Nursing Homes, Operation Theatres, Nurseries, Burn WardsCommercial Areas – Supermarkets, Departmental Stores, Office Buildings, Conference Facility Educational and Recreational Areas – Schools, Auditoriums, Bowling alleys
fresh air unit
8,000 Per Piece
Treated Fresh Air Units
Get Price Quote
When global temperatures are rising continuously, all that people desire is a cooling system that can give them the comfort and freshness. With the emergence of companies like Wave Aircon Private Limited, people can take a sigh of relief. The company has emerged to be highly efficient in matching the demand of the clients in the best way and providing superior quality fresh air treatment unit. The fresh air handling unit offered by the company performs excellent and serves the clients in the best way. The company has a dedicated that ensures that the needs of the clients are met in the most efficient manner. Wave Aircon Private Limited provides products that conform to superior quality standards and serve the clients in the best way.
Air Source Treatment Unit
Get Price Quote
We are offering best Air Source Treatment Unit
Treated Fresh Air Units
Get Price Quote
Airref treated fresh air units are equipped with the latest of components and fitments that impart smooth working and easy maintenance capabilities to them. The flexibly designed units are available in single and double skin casings fitted with statically and dynamically balanced impellers, ISI marked motors, high quality filters and high efficiency cooling heating coils of various capacities.
Treated Fresh Air Units
Get Price Quote
TFA's are meant to cater to large fresh airflow and recovery needs, Treated Fresh Air Units are supplied with various inbuilt options for all HVAC needs, some of the sections/modules/ features are standard modules & others are available as an optional. Heart of the TFA is energy recovery wheel only which recovers Total Enthalpy i.e. both Sensible & latent energy Â