Antibiotic Zone Reader
50,000 - 160,000 Per Piece
1 Piece (MOQ)
The antibiotic zone reader provides a rapid accurate method for determining the strength of antibiotic materials by measuring the diameter of an inhibition zone in a petri-dish. This zone reader measures the diameter of the inhibition zone to 0.02 mm within range of 0 to 35 mm diameter. Light from a source from the top, passes through the transparent and semitransparent portions of the agar, then to a reflecting mirror supported by an arm above the unit. The mirror reflects the light to glass prism mounted at the front of the unit and magnified image of the zone of inhibition is clearly visible on the prism. Details: Accurate method for determining the strength of antibiotic material Microprocessor based design Average of Vertical diameter & Horizontal diameter of inhibited zone Magnified image of inhibited zone is clearly visible on the prism Screen Calibration facility with certified coins Parallel printer port & RS 232 port for taking Test Printer Report Password protection for Real Time Clock Membrane Keypad for easy operation Complies to cGMP (MOC-stainless steel -304 & Stainless Steel-316) IQ/OQ Documentation Elevate Your Antibiotic Strength Determinations with the RAZ-1C Antibiotic Zone Reader In the realm of pharmaceutical testing, precision and speed are of paramount importance. Introducing the RAZ-1C Antibiotic Zone Reader – a beacon of accuracy and efficiency that revolutionizes the determination of antibiotic material potency. Engineered to perfection, this model stands as a testament to cutting-edge technology and unwavering commitment to excellence. Unveiling Precision: At the heart of the RAZ-1C lies an ingenious method for gauging the strength of antibiotic materials with unprecedented precision. By meticulously measuring the diameter of an inhibition zone within a petri-dish, it renders results with an accuracy of 0.02 mm, within the expansive range of 0 to 35 mm. This means no more approximations – just definitive, reliable data that drives your research forward. Technological Brilliance: Bearing the hallmark of microprocessor-based design, the RAZ-1C is the pinnacle of technological sophistication. It seamlessly computes the average of vertical and horizontal diameters of the inhibition zone, ensuring results that leave no room for doubt. Visualize with Clarity: Witness the magic unfold as light journeys from the top source, piercing through transparent and semitransparent agar portions. A reflecting mirror, poised elegantly above the unit, guides this light to a glass prism at the forefront. The result? A magnified, crystal-clear image of the inhibition zone dancing upon the prism screen, providing insights at a glance. Empowering Features: Calibrate with Confidence: Immerse yourself in precision with the calibration facility, fortified by certified coins. Seamless Reporting: A parallel printer port and RS 232 port stand ready to immortalize your findings in detailed Test Printer Reports. Secure Your Data: Real Time Clock benefits from password protection, ensuring your invaluable data remains safeguarded. Effortless Control: Navigate through operations effortlessly with the membrane keypad, designed for intuitive use. Crafted to Perfection: The RAZ-1C not only meets but exceeds the rigorous standards of cGMP, boasting a construction of stainless steel -304 and Stainless Steel-316. This amalgamation of excellence guarantees longevity and resilience in the face of demanding environments. Documentation that Counts: IQ/OQ Documentation elevates your experience, offering comprehensive insights into the instrument’s performance and ensuring compliance with industry regulations. Step into a new era of antibiotic material strength determination with the RAZ-1C Antibiotic Zone Reader. Precision, innovation, and reliability converge to empower your pharmaceutical journey like never before. Your pursuit of excellence deserves nothing less.
1941 Digital Antibiotic Zone Reader
Get Price Quote
1 Piece (MOQ)
EI Digital Antibiotic Zone Reader provides the user, distance in mm with accurate and fast method for determining the strength of antibiotic material. It functions by measuring the diameter from 0 to 80.0 mm of an inhibition zone in a petri-dish. Wells are created on a petri-dish, prepared with agar – agar solution and inoculated with bacteria. After incubation, the bacterial growth cover the dish except for a circular inhibited zone around each disc, it being a function of the strength of the antibiotic. The zone reader accurately measures the diameter of the inhibited zone to 0.1 mm within range of 0 to 80.0 mm diameter. Light is passed through the transparent and semitransparent portions of the agar from a source at base towards up. It then passed to a reflecting mirror supported by an arm above the unit, which reflects the light to glass prism mounted at the front of the unit and magnified image of the zone of inhibition is clearly visible on the prism. Features Accurate method for determining the strength of antibiotic materials. Electronic ‘zero’ adjustment eliminate tedious zero setting on the scale. LED illumination for better visibility of zone. Fine focus adjustment for clear image on the viewing Glass. IQ /OQ Documentation. No effect of ambient light on image. No parallax so no human error in reading. Wide range of measuring diameters from 0 to 80.0 mm.
Best Deals from Antibiotic Zone Reader
Antibiotic Zone Reader
Get Price Quote
Digital antibiotic zone reader determines strength of antibiotic materials by measuring diameters from 0 to 80.0 mm of inhibited zones in petri dishes. Agar in petri dish is inoculated with bacteria, and then sensitivity dishes are dispensed onto dish. After incubation , bacterial growth covers dish except for circular inhibited zone around each disc. Zone diameter is a fiction of antibiotic strengh. Light from base passes up through transparent &semitransparent portions of agar. Adjustable rubber belt sliding , facilitates positioning of dish relative to light source. Light then passes Technical Specification Digital Display 4 digit (9999 max). Dish Size 110mmdia. Magnification 100 mm. / Standard Accessaries - Marking pen, Magnifier Lense Holder. to reflecting mirror which reflects image, on glass prism with horizontal line mark on it. Arc from one edge of circle zone is adjusted tangent with line on viewing glass by the “slider knob”. Now hold the left side knob & turn the right side dial & adjust zero.Then entire dish is to be moved by turning “slider knob” until are from opposite side of inhibited zone is brought tangentto same line. Take down the reading from the dial.
Antibiotic Zone Reader
Get Price Quote
1 Piece (MOQ)
Antibiotic Zone Reader
7,950 Per Piece
10 Piece (MOQ)
Antibiotic Zone Reader
Get Price Quote
1 Piece (MOQ)
SIS – 1347 Most suitable to measure the diameter of the inhibited zone in microbiology, botany, zoology, bacteriology and pathology labs. Unique in design and measures the diameter of the inhibited zone to 0.1 mm within the range of 0 to 35 mm. Light from a source in the base passes up through the transparent and Semi transparent portion of the agar-agar, then to a reflecting mirror supported by an arm above the unit. The mirror reflects the light to a glass prism mounted at the front of the unit and the magnified image of the zone of inhibitions can be clearly seen on the prism. Supplied complete with accessories like prism, petri dish. Suitable for operation on 230 V, 50 Hz single phase AC supply.
Antibiotic Zone Reader
60,000 Per Set
1 Set(s) (MOQ)
An ideal device for determination the strength of antibiotic activity, by measuring the diameter of inhibition zone in a Petri dish. It measures the diameter of inhibition zone to 0.1mm within the range of 0-35mm. Light from source in the base, passes through the transparent and semi transparent of agar, then to refluxed mirror supported an arm above the unit. The mirror reflects the light to the glass prism mounted at the front of unit and magnified image of the zone clearly visible on the prism.
Antibiotic Zone Reader
Get Price Quote
Antibiotic Zone Reader : Antibiotic zone reader, most suitable to measure the diameter of the inhibited zone in microbiology, botany, zoology, bacteriology and pathology labs. The instrument is unique in design and measures the diameter of the inhibited zone to 0.1 mm within the range of 0 to 35 mm. Light from a source in the base passes up through the transparent and semitransparent portion of the agar-agar, then to a reflecting mirror supported by an arm above the unit. The mirror reflects the light to a glass prism mounted at the front of the unit and the magnified image of the zone of inhibitions can be clearly seen on the prism. The instrument is supplied complete with all the required accessories like prism, petri dish, etc. The unit is suitable for operation on 230 V, 50 Hz, single phase AC supply
Digital Antibiotic Zone Reader
Get Price Quote
The antibiotic zone reader provides a rapid accurate method for determining the strength of antibiotic materials by measuring the diameter of an inhibition zone in a petri-dish. In use, the discs are placed on a petri-dish prepared with agar and inoculated with bacteria. After incubation, the bacteria cover the entire dish except for a circular inhibition zone around, it being a function of the strength of the antibiotic. This zone reader measures the diameter of the inhibition zone to 0.02 mm within range of 0 to 35 mm diameter. Light from a source from the top, passes through the transparent and semitransparent portions of the agar, then to a reflecting mirror supported by an arm above the unit. The mirror reflects the light to glass prism mounted at the front of the unit and magnified image of the zone of inhibition is clearly visible on the prism. Features Accurate method for determining the strength of antibiotic material Micro processor based design Average of Vertical diameter & Horizontal diameter of inhibited zone Magnified image of inhibited zone is clearly visible on the prism Calibration facility Printout facility Facility to store 4 zones (optional 6 zones) IQ / OQ Documentation . Advantages An accurate method of determining the strength of antibiotic materials. Magnified image of the inhibition zone is clearly visible on the prism. Less time-consuming for measuring the accurate diameter of an inhibited zone ( 0.1 mm). Easy to operate for single person. Display shows direct reading. Vertical & horizontal reading of the zone stored in memory
Antibiotic Zone Reader
Get Price Quote
Edutek Instrumentation offers antibiotic zone reader, most suitable to measure the diameter of the inhibited zone in microbiology, botany, zoology, bacteriology and pathology labs. The instrument is unique in design and measures the diameter of the inhibited zone to 0.1 mm within the range of 0 to 35 mm. Light from a source in the base passes up through the transparent and semitransparent portion of the agar-agar, then to a reflecting mirror supported by an arm above the unit. The mirror reflects the light to a glass prism mounted at the front of the unit and the magnified image of the zone of inhibitions can be clearly seen on the prism. The instrument is supplied complete with all the required accessories like prism, petri dish, etc. The unit is suitable for operation on 230 V, 50 Hz, single phase AC supply.
Antibiotic Zone Reader
Get Price Quote
The antibiotic zone provides a rapid accurate method for determining the strength of antibiotic materials by measuring the diameter of an inhibited zone in Petri- dish In use, the discs are placed on Petri-dish prepared with agar and inoculated with bacteria. After incubation, the bacterial cover the entire dish except for a circular in – habited zone around being a function of the strength of the antibiotic. This zone reader measures the diameter of the inhibited zone to 0.02 mm within range of 0 to 35 mm diameter. Light from a source in the base, passes through the transparent and semitransparent portion of the agar, then to a reflecting mirror supported by an arm above the unit. The mirror reflects the light to glass prism mounted at the front of the unit and magnified image of the zone of inhibition is clearly visible on the prism. Digital Indications of antibiotic zone diameter using a micro-computer. Measurement range 00.00 to 35.00 mm diameter readability 0.01 mm. Average of two diameter readings in vertical and horizontal direction of inhibited zone. Recall average diameter of inhibited zone. Key operations are acknowledged by beep sound. S.S. calibrated coins for calibration IQ / OQ Documentation Advantages : An accurate method of determining the strength of antibiotic materials. Magnified image of the inhibited zone is clearly visible on the prism. Less time – consuming for measuring the accurate diameter of an inhibited zone. (+/- 0.1 mm) Easy to operate for single person. Display shows direct reading. Vertical & horizontal reading of the zone stored in memory.
Antibiotic Zone Reader
Get Price Quote
Product Description Antibiotic Zone Reader provides a rapid accurate method for determining the strength of antibiotic materials by measuring the diameter of an inhibited zone in petri dish. Features: Measures the diameter of the inhibited zone to 0.02mm with the range of 0 to 35mm. Work on 230volts A.C. 50 C/S
Antibiotic Zone Reader
Get Price Quote
as per order Piece (MOQ)
Antibiotic Zone Reader is most suitable to measure the diameter of the inhibited zone in microbiology, botany, zoology, bacteriology & pathology labs. Our Antibiotic Zone Reader is unique in design & suitable for measuring the diameter of inhibited zone within the range of 0 to 35 mm with accuracy 0.2 mm. Our Antibiotic Zone Reader determines the strength of antibiotic materials rapidly and results obtained are reliable. Highlights : Reliable Unique design Provides rapid result Accurate
Antibiotic Zone Reader
Get Price Quote
SITRO scientific is a leading manufacturer company of "ANTIBIOTIC ZONE READER". We can provide you best quality product at very competitive price.
Antibiotic Zone Reader
Get Price Quote
This Is Very Compact And Designed For Measuring The Diameter Of Finished Zone In Petri Dish, For Determining The Strength Of Antibiotic Materials. This Antibiotic Zone Reader Measures The Diameter Of The Inhibited Zone Within The Range Of 0 To 35mm With Accuracy Of 0.2mm. The Light From Inside Source If The Base Passes Up Through The Transparent And Semitransparent Of The Agar Then To A Reflecting Mirror Situated In An Arm Above The Unit. The Mirror Reflects The Light To A Glass Prism Mounted At The Magnified Image Of The Zone Of Inhibitions Is Clearly Invisible On The Prism.
Antibiotic Zone Reader
Get Price Quote
Antibiotic zone reader offers antibiotic zone reader, most suitable to measure the diameter of the inhibited zone in microbiology, botany, zoology, bacteriology and pathology labs. The instrument is unique in design and measures the diameter of the inhibited zone to 0. 1 mm within the range of 0 to 35 mm. Light from a source in the base passes up through the transparent and semitransparent portion of the agar-agar, then to a reflecting mirror supported by an arm above the unit. The mirror reflects the light to a glass prism mounted at the front of the unit and the magnified image of the zone of inhibitions can be clearly seen on the prism. The instrument is supplies complete with all the required accessories like prism, petri dish, etc. The unit is suitable for operation on 230 v, 50 hz, single phase ac supply.
Antibiotic Zone Reader
Get Price Quote
Mvl Instruments is one of the trustworthy Exporters & Suppliers of Antibiotic Zone Reader. We offer designs and colors that are user friendly and make for a good product for the long run. We also provide for bulk assignments and long distance delivery for the industry. We specialize in providing Antibiotic Zone Reader across global markets, at reasonable price.
Antibiotic Zone Reader
14,500 Per Piece
ANTIBIOTIC ZONE READER (DIGITAL MODEL)
Get Price Quote
Product Description Suitable for measuring the diameter of inhabited zone within the range of 0 to 35 mm with accuracy of 0.1mm, to fix up the strength of antibiotic material. Works on 230 volts single phase AC.
Antibiotic Zone Reader
Get Price Quote
We are a prominent Manufacturer and Supplier of Antibiotic Zone Reader in Haryana, India. These are known for their precise results, durability, perfect finish, sturdy structure, and long life span. These are manufactured in compliance with the latest industrial standards and norms. We are backed by a team of diligent professionals, who thoroughly observe it against the predefined quality parameters before forwarding it to our clients.
Antibiotic Zone Reader
Get Price Quote
Leveraging on our industrial experience, we are chiefly engaged in manufacturing antibiotic zone reader. Available in varied specifications, the antibiotic zone readers supplied by us are extensively used for measuring the diameter of inhibited zone for scientific processes. Furthermore, our antibiotic zone readers are well designed and can be availed at most competitive prices in the markets. suitable for measuring range of 0 to 35 mm. With accuracy of 0.02 mm specifications the equipment operates on 230 volts single phase 50 cs. A.c.
Antibiotic Zone Reader
40,000 - 70,000 Per pc
1 Piece (MOQ)
antibiotic zone reader
Antibiotic Zone Reader
40,000 Per Piece
Antibiotic Zone Reader
Get Price Quote
Most suitable to measure the diameter of the inhibited zone in microbiology, botany, zoology, bacteriology and pathology labs. Unique in design and measures the diameter of the inhibited zone to 0.1 mm within the range of 0 to 35 mm. Light from a source in the base passes up through the transparent and Semi transparent portion of the agar-agar, then to a reflecting mirror supported by an arm above the unit. The mirror reflects the light to a glass prism mounted at the front of the unit and the magnified image of the zone of inhibitions can be clearly seen on the prism. Supplied complete with accessories like prism, petri dish. Suitable for operation on 230 V, 50 Hz, single phase AC supply.
Digital Antibiotic Zone Reader
49,000 Per Piece
1 Piece (MOQ)
Antibiotic Zone Reader
Get Price Quote
ANTIBIOTIC ZONE READER : P-A6 Antibiotic Zone Reader : The Antibiotic zone reader provides a rapid accurate method for determining the strength of antibiotic materials by measuring the diameter of an inhibited zone in petri dish.This zone reader measures the diameter of the inhibited zone to 0.02mm with the range of 0 to 35mm. It works on 220V AC 50Hz. Additional Information: Item Code: P-A6
Antibiotic Zone Reader
Get Price Quote
We offer exclusive range of Antibiotic zone reader. These are fabricated with due perfection using high grade raw material, which is sourced from authorized vendors only. The range is made available in various configurations suiting the needs of different applications. our range is provided for its easy installation and maintenance time to time. Available as per specifications of clients at reasonable market prices.
Antibiotic Zone Reader
Get Price Quote
Antibiotic Zone Reader
Get Price Quote
Suitable for measuring the diameter of inhibited zone within the range of 0 to 35 mm. with accuracy of 0.02 mm. The equipment operates on 230 Volts Single phase 50 c/s. A.C.
Antibiotic Zone Reader
Get Price Quote
Digital antibiotic zone reader determines strength of antibiotic materials by measuring diameters from 0 to 80.0 mm of inhibited zones in petri dishes. Agar in petri dish is inoculated with bacteria, and then sensitivity dishes are dispensed onto dish. After incubation , bacterial growth covers dish except for circular inhibited zone around each disc. Zone diameter is a fiction of antibiotic strengh. Light from base passes up through transparent &semitransparent portions of agar. Adjustable rubber belt sliding , facilitates positioning of dish relative to light source. Light then passes Technical Specification Digital Display 4 digit (9999 max). Dish Size 110mmdia. Magnification 100 mm. Standard Accessaries - Marking pen, Magnifier Lense Holder. to reflecting mirror which reflects image, on glass prism with horizontal line mark on it. Arc from one edge of circle zone is adjusted tangent with line on viewing glass by the “slider knob”. Now hold the left side knob & turn the right side dial & adjust zero.Then entire dish is to be moved by turning “slider knob” until are from opposite side of inhibited zone is brought tangentto same line. Take down the reading from the dial.