Wall Mounted Chlorine Gas Sensor
34,000 Per Piece
1 Piece (MOQ)
Chlorine Sensor
Get Price Quote
Best Deals from Chlorine Sensor
Dissolved Chlorine Sensors
Get Price Quote
We are an eminent Manufacturer, Exporter, Wholesaler and Supplier of Automation and Instrumentation Products. These products are technologically advanced and are known for their durability and efficient performance.We offer Dissolved Chlorine Sensors. Application:Free Chlorine, Inorganic Chlorine Cannot measure with Cyanuric Acid present• Amperometric Two and Three electrode systems with replacement membranes.• 30/40 L/h Flow rate required.• 1 Bar permissable pressure• Single point calibration• Sample must be free of surfactants With the exception of the 4-20mA sensors, where the length is 220mm, the sensors have a length of 175mm and a diameter of 25mm, with plug adaptor connection. They are designed to fit into the available flow cells. The low current produced by the sensors is electronically amplified in the measurement cell. No zero point calibration is necessary, and measurements can be taken in pressure up to 1 BAR. The sensors are temperature compensated, and will operate in the range 0 to 45 degrees C (for the 7 Series, 0-55). The water has to be flowing to obtain a reading, which is why flow cells are recommended. Changes to the minimum flow rate will only slightly affect the measurement signal. Surfactants should not be present in the water being measured (does not apply to the 7 Series probes). For the dual electrode system, the measurement cell is made of gold, and the counter and reference electrodes of silver with silver halogenid coating. A bias voltage (polarisation) is applied between the two electrodes. For the potentiostatic 3 electrode system, the measurement electrode is made of gold, the reference electrode is made of silver with a silver halogenid coating, and the counter electrode of stainless steel. • Handling, commissioning and service are extremely easy. The electrode system has a very long working life, with just the membrane cap subject to wear and tear. This needs to be replaced every year. However, maintenance costs are very low.• The time needed to polarise most of the probes is less than 2 hours.• No zero point calibration is necessary, and it is only necessary to have a single point calibration, only a slope test is required.• Because the flow dependence is so low, various in-line probe housings can be used, and it is possible to fit "in-line".• For most of the probes it is possible to operate up to 1 Bar (higher on request), and this enables the water to be easily returned.• Temperature compensation is integrated in every probe.• 90% of the final value of the measurement can be reached in less than 2 minutes for most measurement probes.• Long term stability is excellent, slope loss is approximately 1% per month.
Chlorine Sensors
Get Price Quote
Made from supreme quality stainless steel, the Chlorine Sensors are used in conjunction with pressure sheath. Our company shares glorious credentials with best Suppliers and Exporters of Chlorine Sensors from Maharashtra, India. High accuracy repeatability and long service life makes our Chlorine Sensors the first choice among customers. We source these Chlorine Sensors from trusted vendors only. Bulk orders of the Sensors are also catered by us within the stipulated time.
Chlorine Dioxide Amperometric Sensors
Get Price Quote
We are offering chlorine dioxide amperometric sensors.
CHLORINE DIOXIDE SENSOR
80,000 Per Piece
CL5: Free Chlorine Sensors
Get Price Quote
The CL series (free chlorine sensors) feature amperometric measurement technology. Designed for disinfection applications in water treatment,for,pools,etc.,these sensors are available in three ranges for detecting ppm level of free chlorine. Choose the CL502 for 0-2ppm, CL505 for 0-5ppm and CL510 for 0-10ppm of free chlorine Typical applications include: Industrial wastewater Cooling water Bottle rinsing Irrigation water in agriculture Sensors output a 4-20mA signal scaled to 0-2 or 0-10ppm. Membrane cap and fill solution are easily replaceable to maximize sensor life. Sensors can be used in new installations with Omicron's flow cell or installed as replacement for other 4-20mA output free chlorine sensors. (Consult Omicron for compatibility). An optional flow meter (FM001) is available to help provide consistent flow for added system stability. Special Features : Amperometric Sensor Technology Real Time Continuous Measurement Ranges: 0-2, 0-5 or 0-10ppm Built-In Temperature Compensation Large Electrolyte Reservoir Replaceable Membrane and Electrolyte
Chlorine Sensors
Get Price Quote
FREE CHLORINE SENSORS
Get Price Quote
FREE CHLORINE SENSORS, AMMONIUM SENSOR, CHLORINE DIOXIDE SENSOR