Earthing Transformers Dealers

(53 products available)
  • Earthing Transformers

    Earthing Transformers

    Get Price Quote

    • Phase: Single Phase
    • Brand Name: Urja Techniques
    • Application of Transformer: Power / Distribution / Furnace etc.
    • Capacity of Transformer: kV
    • Primary Voltage Ratio: kV
    • Range: 2 MVA - 33 kV
    • Cooling Type: Dry Type/Air Cooled,Oil Cooled
    • Secondary Voltage Ratio: Fremycetin Sulphate B.P. 1% w/w
    • Type of Transformer: Oil Cooled / Air Cooled VPI or CRT

    We are supplier and exporter of this product.

    more..
  • Earthing Transformers

    Earthing Transformers

    Get Price Quote

    Earthing Transformers are designed to serve the client’s purpose to the fullest. We manufacture Earthing Transformers as per the given specifications of the customers. Our products are highly acclaimed across the globe due to the fine functioning and comfortable services provided by us. We work as per the customers’ preferences and conditions.

    more..
  • Best Deals from Earthing Transformer

  • Esennar Earthing Transformers

    Esennar Earthing Transformers

    Get Price Quote

    We have gained complete customers satisfaction as we make maintain proper schedules for the delivery of the consignments We are a buyer's best bet when it comes to purchasing Esennar Earthing Transformers.. Our company is a promising supplier.

    more..
  • Earthing Transformer

    Earthing Transformer

    200,000 - 400,000 Per Nos

    1 Piece (MOQ)

    • Country of Origin: India
    • Type: Earthing Transformer
    • Certification: ISO 9001:2008
    • Application: Power
    • Color: Grey
    • Warrenty: 1 Year
    • Conditioin: New
    • Brand Name: ALLIANZ

    We have gained expertise in delivering a quality range of Earthing Transformers Earthing or Neutral Grounding Transformers are also manufactured by us. It is used large Sub Stations where Earthing is done through this Transformer. It is a special application Transformer.

    more..
  • Earthing Transformer

    Earthing Transformer

    Get Price Quote

    • Application: Lighting
    • Automatic Grade: Automatic
    • Phase: Single
    • Coil Number: Autotransformer
    • Voltae: 240v
    • Warranty: 1 Year

    Standard Fittings Include Lifting Lugs, Oil level Gauge, Rating & Diagram Plate, HV & LV Bushings with fittings, Skid Base/Roller Arrangement, Silica gel Breather, Drain/Filter Valves, Thermometer, Pressure Relief Device/Explosion vent.   Optional Fittings Include Terminal Connectors, Magnetic Oil Level Gauge, Oil Temperature Indicator, Winding Temperature Indicator, Buchholz Relay, RTCC Panel, Condenser Type Bushing for voltage class of 33 kV & 66 kV, Off circuit Tap Switch / On-load Tap Changer with RTCC, HV / LV Cable Boxes, Disconnecting, Epoxy / Touch proof Bushings with connector, Siphon Thermo Filter, Conservator, Lightening Arrester, Arcing Horns, Protective Fuse, Secondary Circuit Breaker, Bird Guard.

    more..
  • Earthing Transformer

    Earthing Transformer

    118,000 - 1,246,000 Per Number

    1 Pair (MOQ)

    • Country of Origin: India
    • Type: Earthing Transformer
    • Certification: 9001: 2015
    • Application: Power
    • Color: Grey
    • Phase: Three
    • Brand Name: True Power Limited
    • Capacity(KVA): 25

    True Power Limited manufactures transformers and supplies in India. We manufacture power, Isolation, Distribution transformers, and more at the best price.   

    more..
  • Earthing Transformer

    Earthing Transformer

    Get Price Quote

    Our organization is involved in supplying an eclectic array of products out of which is Earthing Transformer.   Details : 33 KV, Through fault current of 1000 A for 30 sec.

    more..
  • Electrical Earthing Transformer

    Electrical Earthing Transformer

    100,000 Per Unit

    • Phase: Three Phase
    • Country of Origin: Made in India
    • Brand Name: NGG Power Tech
    • Current: 21 A
    • Cooling Type: Oil Cooled
    • Power: Upto 4 MVA
    • Material: Mild Steel
    more..
  • Earthing Transformers

    Earthing Transformers

    Get Price Quote

    We manufacture Earthing transformers that are normally provided in 3-phase system, which is ideal for neutral and earth fault protection.The earthing transformer has zig-zag (interstar) winding to achieve the required zero phase impedance. In addition an auxiliary winding can also be provided to meet the requirement of auxiliary power supply. ONAN ONAF cooling with conventional pressed steel radiators. The range is offered as per the site requirements. Specifications: * 36 KV Class * ONAN ONAF cooling with conventional pressed steel radiators * Zig-zag (interstar) winding to achieve the required zero phase impedance * Auxiliary winding can also be provided to meet the requirement of auxiliary power supply

    more..
  • Earthing Transformers

    Earthing Transformers

    Get Price Quote

    Neutral Earthing transformers are normally provided in 3-phase system, which is without neutral and earth fault protection.Neutral earthing transformer is having zig-zag (interstar) winding to achieve the required zero phase impedance. In addition an auxiliary winding can also be provided to meet the requirement of auxiliary power supply.ONAN /ONAF cooling with conventional pressed steel radiators. The range includes up to 33 KV systems and as per the site requirements. A Earthing ( zigzag) transformer is a special purpose transformer with a zigzag or 'interconnected star' winding connection, such that each output is the vector sum of two phases offset by 120�. Its applications are for the creation of a missing neutral connection from an un-grounded, 3-phase system to permit the grounding of that neutral to an earth reference pointand also harmonic mitigation, as it can suppress triplet (3rd, 9th, 15th, 21st, etc.) harmonic currents, to supply 3-phase power as an autotransformer (serving as the primary and secondary with no isolated circuits), and to supply non-standard phase-shifted 3-phase power. Nine-winding three-phase transformers, typically have 3 primaries and six identical secondary windings which be used in zigzag winding connection as pictured. As with the conventional delta or wye winding configuration three-phase transformer, a standard stand-alone transformer containing only six windings on three cores can also be used in zigzag winding connection, such transformer sometimes being referred to as a zigzag bank. In all cases, six or nine winding, the first coil on each zigzag winding core is connected contrariwise to the second coil on the next core. The second coils are then all tied together to form the neutral and the phases are connected to the primary coils. Each phase, therefore, couples with each other phase and the voltages cancel out. As such, there would be negligible current through the neutral point, which can be tied to ground. Each of the three "limbs" are split into two sections. The two halves of each limb have the equal number of turns and they're wound in opposite directions. With the neutral grounded, during a phase to ground short fault, a third of current returns to the fault current and the remainder must go through two of the three phases when used to derive a grounding point from a delta source. If one phase, or more, faults to earth, the voltage applied to each phase of the transformer is no longer in balance; fluxes in the windings no longer oppose. (Using symmetrical components, this is Ia0 = Ib0 = Ic0.) Zero sequence (earth fault) current exists between the transformer’s neutral to the faulting phase.The purpose of a zigzag transformer in this application is to provide a return path for earth faults on delta-connected systems. With negligible current in the neutral under normal conditions, providing the defective load will be automatically disconnected in a fault condition, an undersized transformer may be used only as short time rating is required (i.e. the transformer can only carry full rated current for, say, 60 s). Impedance should not be too low for desired maximum fault current. Impedance can be added after the secondaries are summed to limit maximum fault currents(the 3Io path). 

    more..
  • Earthing Transformers

    Earthing Transformers

    Get Price Quote

    We manufacture earthing transformers that are normally provided in 3-phase system, which is ideal for neutral and earth fault protection.the earthing transformer has zig-zag (interstar) winding to achieve the required zero phase impedance. In addition an auxiliary winding can also be provided to meet the requirement of auxiliary power supply. Onan onaf cooling with conventional pressed steel radiators. The range is offered as per the site requirements. Specifications: 36 kv class onan onaf cooling with conventional pressed steel radiators zig-zag (interstar) winding to achieve the required zero phase impedance auxiliary winding can also be provided to meet the requirement of auxiliary power supply

    more..
  • Neutral Earthing Transformers

    Neutral Earthing Transformers

    Get Price Quote

    Neutral Earthing transformers are normally provided in 3-phase system, which is without neutral and earth fault protection. We provide Earthing transformer up to 2MVA current rating and voltage class of 33kV. Other higher specifications are manufactured on demand basis against specification. Neutral Earthing transformer is having zig-zag (inters tar) winding to achieve the required zero phase impedance. In addition an auxiliary winding can also be provided to meet the requirement of auxiliary power supply in these electrical Earthing transformers.   Grounding transformer is used to provide a ground path to either an ungrounded “Y” or a delta connected system & serves to limit the magnitude of transient over voltages when re-striking ground faults occur. provide relatively low impedance path to ground, thereby maintaining the system neutral at or near ground potential Provide a source of ground fault current during line to ground faults. Permit the connection of phase to neutral loads is desired. Technical Specifications Manufactured under specification of IS:3151 Current rating up to 2 MVA. High voltage up to 36 kV. Low voltage up to 0.69 kV. Classes E2, E3, C2, F1. Frequencies: 50 Hz, 60 Hz and 16 2/3 Hz. Cooling: ONAN/ONAF/AN / ANAN / ANAF. Insulation system temperature: F and H. Partial discharges Protection degree: IP00 – IP54. Features: capable of withstanding a fault current at rated voltage and frequency through the neutral for a time duration of 30 seconds without using neutral grounding resistor and without exceeding the temperature. withstanding the mechanical and thermal stresses caused by the rated short time current flowing in the windings under fault conditions. Standard Fittings: Prime Bushings Secondary Bushings Conservator Silica Gel Breather Cable Terminations Oil Level Indicator Filling Device Thermometer pocket Marshalling Box Earthing Terminal Rating & Diagram Plate Lifting Lugs Drain Plug Buchholz Relay Inspection Cover Optional Fittings: HV / LV Cable Box Magnetic Oil Level Gauge Winding Temperature Indicator Off circuit Tap Switch Siphon Thermo filter Rollers (Uni-Directional / Bi-Directional) Drain Valve Conservator and Silica gel Breather Pressure Relief Device Off Circuit Tap changer / OLTC

    more..
  • Earthing Transformer

    Earthing Transformer

    Get Price Quote

    • Certification: ISI Certified
    • Application: Industrial
    • Automatic Grade: Automatic
    • Phase: Single
    • Warranty: 1 year
    • Features: Vector groups are zigzag or wye/delta and No phase Displacement

    We are the main supplier of this product.

    more..
  • Earthing Transformers

    Earthing Transformers

    Get Price Quote

    • Features: Vector groups are zigzag or wye/delta and No phase Displacement

    It is a special – purpose transformer with a Zigzag or interconnected star winding connection, such each output is the vector sum of two phases offset by 120°. When a neutral earthing is required in a 3 phase system and no suitable neutral is available, a neutral earthing to be provided by using a Grounding transformer.

    more..
  • Earthing Transformers

    Earthing Transformers

    Get Price Quote

    Neutral Earthing transformers are normally provided in 3-phase system, which is without neutral and earth fault protection. Neutral earthing transformer has zig-zag (interstar) winding to achieve the required zero phase impedance. In addition an auxiliary winding can also be provided to meet the requirement of auxiliary power supply. ONAN / ONAF cooling with conventional pressed steel radiators. The range includes up to 33 KV systems and as per the site requirements. A Earthing ( zigzag ) transformer is a special purpose transformer with a zigzag or 'interconnected star' winding connection, such that each output is the vector sum of two phases offset by 120°. ts applications are for the creation of a missing neutral connection from an un-grounded, 3-phase system to permit the grounding of that neutral to an earth reference point and also harmonic mitigation, as it can suppress triplet (3rd, 9th, 15th, 21st, etc.) harmonic currents, to supply 3-phase power as an auto transformer (serving as the primary and secondary with no isolated circuits), and to supply non-standard phase-shifted 3-phase power. Nine-winding three-phase transformers, typically have 3 primaries and six identical secondary windings which be used in zigzag winding connection as pictured. As with the conventional delta or wye winding configuration three-phase transformer, a standard stand-alone transformer containing only six windings on three cores can also be used in zigzag winding connection, such transformer sometimes being referred to as a zigzag bank. In all cases, six or nine winding, the first coil on each zigzag winding core is connected contrariwise to the second coil on the next core. The second coils are then all tied together to form the neutral and the phases are connected to the primary coils. Each phase, therefore, couples with each other phase and the voltages cancel out. As such, there would be negligible current through the neutral point, which can be tied to ground. Each of the three "limbs" are split into two sections. The two halves of each limb have the equal number of turns and they're wound in opposite directions. With the neutral grounded, during a phase to ground short fault, a third of current returns to the fault current and the remainder must go through two of the three phases when used to derive a grounding point from a delta source. If one phase, or more, faults to earth, the voltage applied to each phase of the transformer is no longer in balance; fluxes in the windings no longer oppose. (Using symmetrical components, this is Ia0 = Ib0 = Ic0.) Zero sequence (earth fault) current exists between the transformer’s neutral to the faulting phase. The purpose of a zigzag transformer in this application is to provide a return path for earth faults on delta-connected systems. With negligible current in the neutral under normal conditions, providing the defective load will be automatically disconnected in a fault condition, an undersized transformer may be used only as short time rating is required (i.e. the transformer can only carry full rated current for, say, 60 s). Impedance should not be too low for desired maximum fault current. Impedance can be added after the secondaries are summed to limit maximum fault currents(the 3Io path). An application example : A combination of Y (wye or star), delta, and zigzag windings may be used to achieve a vector phase shift. For example, an electrical network may have a transmission network of 110 kV/33 kV star/star transformers, with 33 kV/11 kV delta/star for the high voltage distribution network. If a transformation is required directly between the 110 kV/11 kV network an option is to use a 110 kV/11 kV star/delta transformer. The problem is that the 11 kV delta no longer has an earth reference point. Installing a zigzag transformer near the secondary side of the 110 kV/11 kV transformer provides the required earth reference point. Application in following industries : Chemical, Pharmaceuticals, Steel, Textile, Engineering, Plastic, Cement, Refineries, Mining, Captive Power Projects, Hydro Power Projects, Wind Mill Farms, Construction Houses, Pharma, Electrical, Electronics, Renewable Energy, Automobile.

    more..
  • Earthing Transformer

    Earthing Transformer

    Get Price Quote

    We are into offering clients a dependable range of Earthing Transformer. The Earthing Transformers are available in both oil cooled and dry type and extensively used for various battery chargers. These Earthing Transformers are manufactured with the best quality raw materials and are highly appreciated by clients across the country. We are known as prominent Earthing Transformer Manufacture and Supplier. Attributes : Easy to operateMaintenance freeLonger working lifeEffectual performance Used In : Textile Industry Steel IndustrySugar IndustryFoundry SmeltingTea EstatesGeneral Engineering

    more..
  • Earthing Transformers

    Earthing Transformers

    Get Price Quote

    Neutral Earthing transformers are normally provided in 3-phase system, which is without neutral and earth fault protection. Neutral earthing transformer is having zig-zag (interstar) winding to achieve the required zero phase impedance. In addition an auxiliary winding can also be provided to meet the requirement of auxiliary power supply. ONAN /ONAF cooling with conventional pressed steel radiators. The range includes up to 33 KV systems and as per the site requirements. A Earthing ( zigzag) transformer is a special purpose transformer with a zigzag or 'interconnected star' winding connection, such that each output is the vector sum of two phases offset by 120°.  Its applications are for the creation of a missing neutral connection from an un-grounded, 3-phase system to permit the grounding of that neutral to an earth reference pointand also harmonic mitigation, as it can suppress triplet (3rd, 9th, 15th, 21st, etc.) harmonic currents, to supply 3-phase power as an autotransformer (serving as the primary and secondary with no isolated circuits), and to supply non-standard phase-shifted 3-phase power. Nine-winding three-phase transformers, typically have 3 primaries and six identical secondary windings which be used in zigzag winding connection as pictured. As with the conventional delta or wye winding configuration three-phase transformer, a standard stand-alone transformer containing only six windings on three cores can also be used in zigzag winding connection, such transformer sometimes being referred to as a zigzag bank. In all cases, six or nine winding, the first coil on each zigzag winding core is connected contrariwise to the second coil on the next core. The second coils are then all tied together to form the neutral and the phases are connected to the primary coils. Each phase, therefore, couples with each other phase and the voltages cancel out. As such, there would be negligible current through the neutral point, which can be tied to ground. Each of the three "limbs" are split into two sections. The two halves of each limb have the equal number of turns and they're wound in opposite directions. With the neutral grounded, during a phase to ground short fault, a third of current returns to the fault current and the remainder must go through two of the three phases when used to derive a grounding point from a delta source. If one phase, or more, faults to earth, the voltage applied to each phase of the transformer is no longer in balance; fluxes in the windings no longer oppose. (Using symmetrical components, this is Ia0 = Ib0 = Ic0.) Zero sequence (earth fault) current exists between the transformer’s neutral to the faulting phase. The purpose of a zigzag transformer in this application is to provide a return path for earth faults on delta-connected systems. With negligible current in the neutral under normal conditions, providing the defective load will be automatically disconnected in a fault condition, an undersized transformer may be used only as short time rating is required (i.e. the transformer can only carry full rated current for, say, 60 s). Impedance should not be too low for desired maximum fault current. Impedance can be added after the secondaries are summed to limit maximum fault currents(the 3Io path). An application example: A combination of Y (wye or star), delta, and zigzag windings may be used to achieve a vector phase shift. For example, an electrical network may have a transmission network of 110 kV/33 kV star/star transformers, with 33 kV/11 kV delta/star for the high voltage distribution network. If a transformation is required directly between the 110 kV/11 kV network an option is to use a 110 kV/11 kV star/delta transformer. The problem is that the 11 kV delta no longer has an earth reference point. Installing a zigzag transformer near the secondary side of the 110 kV/11 kV transformer provides the required earth reference point.

    more..
  • Earthing Transformers

    Earthing Transformers

    Get Price Quote

    we ofer Earthing Transformers. Our company is recognized as one of the most preeminent neutral earthing transformers suppliers and exporters from India. The earthing transformers are counted among the most economical products as these are available at reasonable prices and do not require frequent maintenance. We use superior quality material in the manufacturing of grounding transformers that help us in providing a product that is highly durable and resistive to corrosion. The delivery of these transformers is made with the stipulated time period.

    more..
  • Earthing Transformer

    Earthing Transformer

    Get Price Quote

    We have gained expertise in delivering a quality range of Earthing Transformers with various capacities. The wide range of Earthing Transformers offered by our firm is well designed by experts in compliance with the international quality standards.   In cases where the neutral point of three phase system is not accessible like the system connected to the delta connected side of an electrical power transformer, an artificial neutral point may be created with help of a zigzag connected Earthing Transformer. This is a core type transformer with three limbs. Every phase winding in zigzag connection is divided into two equal halves. One half of which is wound on one limb and other half is wound on another limb of the core of transformer. End point of all three windings ultimately connected together and forms a common neutral point. Now if any fault occurs at any of the phases in delta connected system, the zero sequence fault current has close path of circulating through earth as shown in the figure. In normal condition of the system, the voltage across the winding of the Earthing Transformer is 1/V3 times of rated per phase voltage of the system. But when single line to ground fault occurs on any phase of the system, as shown in the figure, zero sequence component of the earth fault current flows in the earth and returns to the electrical power system by way of earth star point of the Earthing Transformer. It gets divided equally in all the three phases. Hence, as shown in the figure,    the currents in the two different halves of two windings in the same limb of the core flow in opposite directions.  And therefore the magnetic (lox set up by these two currents will oppose and neutralize each other. As there is no increase in flux due to fault current, there is no extra dcp/dt means no extra voltage induced across the winding   and no choking effect occurs to impede the tow of fault current. So it can be concluded like that, the zigzag type Earthing or grounding transformer maintains the rated supply voltage at normal current as well as when a solid   single line to ground fault current flows through it. The rated voltage of an Earthing or grounding transformer is the line to line voltage on which it is intended to be used. Current rating of this transformer is the maximum neutral current in Amperes that the transformer is designed to carry in fault condition for a specific time. Generally the time interval, for which transformer designed to carry the maximum fault current through it safely, is taken as 9 second.  

    more..
  • Earthing Transformer

    Earthing Transformer

    Get Price Quote

    We are offering earthing transformer. Specification 3 phase, oil immersed zig-zag connected transformers with voltage class upto 33kv class. vector group – zn0zn0yn11zn0yn11d application – indooroutdoor continuous operation standards – is 2026iec 60076 fittings & accessories – as per customer requirements. special features design ensures the zero phase impedance & fault current. limits the magnitude of transient over voltages. long life span

    more..