Fan Silencers Dealers

(26 products available)
  • fan silencer

    fan silencer

    Get Price Quote

    We are offering fan silencers industrial fan installations, small or large, produce noise. This fan noise is one of the most predominant noise sources in an industrial plant. The magnitude and intensity of noise will vary depending on fan size, horse power, air flow, type and number of blades, static pressure, rotational speed, etc. Fans normally deliver a large volume of air at relatively low static pressures usually measured in inches of water. The rotating action of vanes produce a broad band noise spectrum however, the noise in mid to high frequency range is heard to be louder and requires to be treated for achieving noise control. Generally, silencers are used at intake and discharge of fan installations for treating air borne noise. Fan silencers usually require absorptive type design as they are well known for better attenuation in mid and high frequency range (500-8000 hz). The effectiveness of absorption material progressively reduces at frequencies above and below this range.

    more..
  • Fan Exhaust Silencer

    Fan Exhaust Silencer

    Get Price Quote

    We are offering fan exhaust silencer, the fan exhaust silencers offered by us are designed with a series of rectangular circular baffles consisting of mineral wool, scrim cloth or wire mesh, used in reducing the airborne and structural noise. These are very effective in reducing high frequency noise levels to the acceptable sound frequency.

    more..
  • Best Deals from Fan Silencers

  • fan silencer

    fan silencer

    Get Price Quote

    The fan silencer is used to reduce the suction and discharge noise of the fan. It is an absorptive type silencer and is very effective for high frequency noise attenuation. Consequently fan silencers shall be supplied in rectangular shape.The internal of fan silencer is constructed with series of rectangular baffle with aerodynamic design to offer minimum pressure drop. The following data are required to design fan silencer. Application Flow rate Temperature Fan inlet / outlet size (Depending on application) Allowable pressure drop Silenced noise level requirements

    more..
  • CENTRIFUGAL FAN SILENCER MANUFACTURER

    CENTRIFUGAL FAN SILENCER MANUFACTURER

    Get Price Quote

    The centrifugal fan silencers are normally selected on the basis of maximum allowable pressure drop at rated flow and the silencing criteria. These silencers are usually sized for around 5000 to 5500 FPM velocity but not exceeding 7500 FPM velocity to prevent excessive self generated noise and aerodynamic noise generation. While selecting the centrifugal fan silencer, it must be ensured that the flow area throughout the silencer is sufficient to accommodate the air flow without imposing excessive restriction. Centrifugal Fan Silencers must be carefully matched to the fan inlet or outlet air profile to provide the most economical fan noise control with the lowest additional static pressure requirements. Galvanized, stainless steel and painted constructions are all available. Dissipative media filled, media filled with film liner, and No-Media designs are selected to suit the application. Numerous accessories are available for filtering, rain hoods, flow measurement, bird screens, and flange connection types. Baffles Cooling Systems works hard to make sure these concerns are alleviated with proper design regarding Centrifugal fan silencers.     Fan Noise Varies with Static Pressure Fan Efficiency Air Flow Fan Speed Major source of centrifugal fan noise are Air Inlet and Outlet of primary fans Inlet of FD fans and the outlet of ID fans Fan casing Motor       Centrifugal Fan Silencer Features: Heavy gauge perforated sheet is used. Lifting lugs and saddle are provided with proper calculating load and stress. Heat Resistant Aluminum Paint is applied on the surface area (800°C) based on customer requirement. Quality acoustic fills and Insulation is used. Sandblasting is done on the surface area. We have qualified welders for all types of welding joints for structural work. We have approval from third party inspection for WPS, PQR and WPQ records for all the welding positions like 1G, 2G, 3G, 4G, 6G. We have NDE LEVEL-II inspector for RT, UT, VT, PT, MT

    more..
  • Silencers & Fans

    Silencers & Fans

    Get Price Quote

    Commercial Silencers: We provide excellent range of Silencers. Under this range, we include ResidentialSilencer and many more. These products are extensively used in generators for making low noise while operating. The offered range are appreciated for their features such as durability, high performance and low maintenance. Residential Silencer We are reckoned as a reliable firms offering Residential Silencer to our valuable customers. These products are manufactured using quality mild steel and is dome shaped, which provides more durability. Available in different specifications, our range can also be customized to meet the specific application requirements of our client's.   Application: Internal Combustion Engines Enclosures / canopy’s Blowers Features: Advanced Acoustical Design Heavy duty all welded constriction and long life Heat resistance painted Mality chambered Drain connection Available in: Inline Inlet and outlet Middle side in, End out Side inlet & Inline out let Side Inlet & Side out let Specifications: Noise range: Bellow 75 dBa Expected Attenuation – 18 to 25 dB     Hospital Grade Silencer Avail from us a comprehensive range of Hospital Grade Silencer that are can manufactured in different sizes and specifications. These products are extremely effective where noise level required very low. These Silencers are widely used in hospitals for reducing noise of generators installed in the hospital premises. Most supercharged & turbo charged engines are silenced with this design.   Application: Residential area where ambient noise levels are very low Features:   Advanced Acoustical Design Heavy duty all welded constriction and long life Heat resistance painted Mality chambered Drain connection Available in: Inline Inlet and outlet Middle side in, End out Side inlet & Inline out let Side Inlet & Side out let   Details: Expected Attenuation (Hospital Grade Silencer): 35 to 40 dB Expected Attenuation (Critical Grade Silencer): 30 to 38 dB   Low Pressure Drop Silencers   We are engaged in offering all types of Low Pressure Drop Silencers that are available in different sizes and technical specifications. These products are manufactured by making use of advanced technology and premium quality raw material. Owing to their features like corrosion-resistance, durability, long service life and high performance, these products are highly appreciated by the clients. Details: Expected Attenuation (PLPS Model) - 18to 25 Db Expected Attenuation (Semi Critical Grade)-25 to 32 Db Application: Internal Combustion Engines Blower intakes and discharges Vacuum pump discharges Turbo charged reciprocating engines with low allowable back pressure Features: Advanced Acoustical Design Heavy duty all welded constriction and long life Heat resistance painted Drain connection Available in: Inline Inlet and outlet Middle side in, End out Side inlet & Inline out let Side Inlet & Side out let     Duct Silencers We offer a range of superior quality Duct Silencers that provides complete acoustic and thermal insulation. These Duct Silencers are widely appreciated by our clients which are situated all round the nation. The silencers permit air to flow through while reduces the noise by absorbing it. In selecting a silencer, a balance between noise attenuation and pressure drop need to be considered carefully. Specifications: Temperature Range: -30 °C/+150 °C Operating Pressure: 3000 Pa Maximum Air Velocity: 30 m/s Thickness of Duct: 25 ~ 27 micron     Exhaust Silencers We are the eminent manufacturer and supplier of Exhaust Silencers that are precise manufactured using high-grade basic material and the latest technologies. We are backed by cutting edge technology which helps us manufacture best quality products out of raw materials. Our quality controllers conduct tests based on the parameters including structural durability, crack detection. Specifications: Material: Mild steel Noise reduction: 30 dB Tube size: 04~16 mm   Vent Silencers Our Vent Silencer are made by using superior quality raw material, this range of Vent Silencers our clients can avail from us. The unwanted sound of these vent moves to the atmosphere and increases the noise pollution. These Vent Silencers are widely appreciated by our clients which are situated all round the nation. Application: Oil & Gas Processing Industrial Processing Chemical Processing Heat recovery Systems Steam Boilers Features: Advanced Acoustical Design and High efficiency Acoustic Pack Heavy duty all welded constriction and long life Heat resistance painted High quality sound absorbing material Available in: Inline Inlet and outlet Side inlet & Inline out let   Air Silencers We are engaged in manufacturing Air Silencers that is appreciated by the clients for high quality standards and optimum performance. The raw materials we use are of best quality and are known for their robust and resistant to nature. Our range is known for its excellent quality and finest results. We offer straight through absorptive silencer with intake filters. Specifications: Operating Pressure: 0 ~ 1.0 MPa Temperature Range: 5 ~ 60 °C Material: Brass, Plastic     Rotary Blower Silencers Owing to our expertise, we are manufacturing and supplying superior quality Rotary Blower Silencers. As these Rotary Blower Silencers, more often than not, run continuously to meet operational requirements, emit continuously noise levels. Used in internal combustion engines, compressors and blowers, the products are easy to install and require minimal maintenance. Specifications: Resistance loss:

    more..
  • Industrial Fan Silencers

    Industrial Fan Silencers

    Get Price Quote

    Primary air fans, forced draft fans, and induced draft fans generally require some form of acoustical treatment. Most applications require inlet andor outlet silencers to meet Noise Standards and other noise requirements. For continuous exposure, a maximum of 90 dBA is generally specified to avoid hearing damage. When conversation near the fan is desired, levels of 80 dBA and less are often needed. We designs and manufactures a complete line of silencers for application on all fan types. Computer-enhanced technology developed for fan, turbine, and other air-moving equipment enables Us do offer a cost-effective solution to every fan silencing application. We offers four designs, each with unique advantages, depending upon application-specific requirements for octave band attenuation, pressure drop, and space utilization.

    more..
  • fan silencers

    fan silencers

    Get Price Quote

    Both suction and discharge silencers shall be supplied either in circular or rectangular construction for fan blower and turbo blowers. The rectangular silencer shall be of absorptive type installed either at suction side or at discharge side of fan blower. The internals of the silencer comprises a series of acoustic splitter elements arranged in parallel inside the rectangular steel casing. This would ensure the flow of airgases through the rectangular air gap between acoustics splitters and thus offering a minimum pressure drop. The leading and trailing edge of the acoustic splitters will be designed aerodynamically to offer minimum resistance to the flow medium.

    more..
  • fan silencers

    fan silencers

    Get Price Quote

    Leveraging on our extensive market knowledge, we are providing a high quality range of Industrial Fan Silencer. However, in any mechanical device that requires components to rotate at high speeds, noise can become problematic.

    more..
  • fan silencers

    fan silencers

    Get Price Quote

    In order to have the basic data input for design-noise level measurements are carried out under normal load conditions, full load conditions and also with damper closed conditions. The measurements are carried out at number of locations at fan inlet and at distances of 1 or 2 or 3 metres. The noise contour at number of octave frequency bands are plotted and the Silencer is designed on the following considerations. - The source noise level at fan inlet under full load conditions shall be brought down nearer to NC80 Curve by suitable combination of acoustic systems. - The pressure loss across the silencer shall be around 25 mm wcl. The selected combination of acoustic systems may consist of any one or a combination of two or three components. Multiple duct baffles with acoustic material of resin bonded fibre glass mineral wool supported inside perforated sheets at fan inlet. Alternatively circular central core intake Silencer with centre core , baffle supports and housing, lined with mineral wool inside the perforated sheet. Outlet Silencer- baffle type or Centre core type Sound insulation with mineral wool inside perforated sheets in the scroll portion of the casing , inlet duct , suction Chamber and outlet duct Coating of all the fan parts in flow area with sound insulation material. For improved noise insulation a fan enclosure with silencer lining and weather protection

    more..
    Isel
    Chennai
    0.0 View Profile
  • Blower and Fan Silencer

    Blower and Fan Silencer

    Get Price Quote

    Inlet and outlet silencers for rotary, roots type, blowers, screw compressors and centrifugal fans. Units are designed to eliminate the tonal noise produced by these types of equipment.

    more..
  • fan silencer

    Get Price Quote

    The construction of the fan silencer will be circular or rectangular type. The fan silencer shall be absorptive type silencer . We can install at suction or discharge side of the fan . It is very effective for high frequency noise attenuation.

    more..
  • fan silencers

    fan silencers

    Get Price Quote

    fan silencers, Throttle Body, Connecting Rod, Engine Fan

    more..
  • fan silencer

    Get Price Quote

    • Color: Custom
    • Size: Custom

    Fan’s inlet and outlet will have a lot of noise due to huge amount of working fluid and due to fan speed. The silencer shall be of absorptive type installed either at suction side or discharge side of the fan.

    more..
  • fan silencers

    fan silencers

    Get Price Quote

    fan silencers, Reciprocating engine, Rocker Lever, timing belt tensioner

    more..
  • FD FAN SILENCERS

    FD FAN SILENCERS

    Get Price Quote

    FD FAN SILENCERS

    more..
  • fan silencers

    fan silencers

    Get Price Quote

    fan silencers, Engine Fan, Cut Section Model of Reciprocating Pump

    more..
  • fan silencers

    fan silencers

    Get Price Quote

    fan silencers, Acoustic Enclosures, Guillotine Gates

    more..
  • Fan- Blower Silencer

    Get Price Quote

    Fan- Blower Silencer, Start Up Vent Silencer

    more..
  • Blower Fan Silencers

    Get Price Quote

    Blower Fan Silencers, Suction and Discharge Silencer

    more..
  • PA Fan Silencer

    Get Price Quote

    PA Fan Silencer, sound proof cabin, Start Up Vent Silencer

    more..
Filter by City
top