Faulted Circuit Indicators Dealers

(17 products available)
  • fault passage indicator

    fault passage indicator

    Get Price Quote

    • Application: Laboratory
    • Brand Name: Powerinst
    • Voltage: 240 V
    • Frequency: 50 Hz
    • Packaging Type: Carton Box
    • Country of Origin: Made in India

    Fault Passage Indicators are useful for Failure Detecting and Condition-Monitoring in Power-Distribution Networks. The main function of fault passage indicating system is to identify faults occurring in the downstream section from the point of its installation in the medium voltage system. This is achieved by continuous monttoring of voltage presence and current flow In medium voltage line.   Features : Permanent Earth-faults : Indication of permanent earth-faults by double blinking of the Earth fault LED. 2nd short-circuit pass-through : Indication of a second short-circuit passing through by double blinking of the respective short-circuit LED Separate fault response delays: The fault response delay for short-circuits & earth-faults can be adjusted individually. Optional three relay contacts: The indicator can be equipped with two remote contact relays to indicate earth-faults and short-circuits separately and one contact for FPI healthy on battery. Optional power supplies : 24 V DC power supply wlth lithium rechargeable battery backup.   Specification : SHEET Adjustable phase to phase short-circuit trip current 200/ 400/ 500/ 600/ 800/1000A (+-10 %) Adjustable phase to phase Earth-fault tip current :10/ 20 /40 / 60 / 80 /100 * A (+-10 %) Adjustable short circuit response delay time 80 / 100 / 120 / 160 *ms Adjustable earth fault response delay earth-fault adjustable: 80 /100 /120 /160 * ms Indications Red Indication for short circuit and earth fault and yellow for battery low Manual push button Is provided to Reset of the Indicator On site function test Protection class; CT's IP67 EMI according to IEC 1000-4-2, IEC 1000-4-3 Operation temperature range -25°C to +70°C SCADA contact - 1 - Change-over contact 2-Optional NO contact for separate earth-fault and short-circuit indication 3 - Permanent/ wipe contact can be selected on site by a dip switch, time 100 m sec max. 230 V AC/ max. 2 A / max. 30 W.

    more..
  • fault passage indicator

    fault passage indicator

    Get Price Quote

    • Application: Industrial Use
    • Voltage: 0-12 VDC
    • Accuracy: 10-15%
    • Housing: Polycarbonate
    • Operating Temp: -30
    • Angle of Visibility: 0-180 Deg
    more..
  • Best Deals from Faulted Circuit Indicators

  • Faulted Circuit Indicator

    Faulted Circuit Indicator

    Get Price Quote

    • Condition: New
    • Angle of Visibility: 360 Degree flashing insight
    • Applicable Voltage Range: 7kV - 13 kV
    • Applicable Current Range: Up to 600A
    • Applicable Power Frequency Range: 50Hz +- 5 %
    • Fault Flashing Interval: 5s
    • Duration of Flashing: 50ms
    • Sensitivity and accuracy: (0 - 100)A +-3A, (100 - 600)A +-3%
    • Static Power Consumption: Less than 20uA
    • Auto Reset Time: (1 - 48)h - User-selectable
    • Resetting Facility: Self reset / Manual / Remote
    • Identification of Fault Current Duration: (20 - 40) ms
    • MTBF: Greater than 70000h
    • Impulse Current With Stand: 31.5kA for 2s
    • Degree of Protection: IP67
    • Weight: less than 500g, 5kg approx
    • Outline Dimension: (75 x 115)mm approx - cylindrical, (355 x 293 x 255)mm
    more..
  • faulted circuit indicators

    faulted circuit indicators

    Get Price Quote

    • Housing: Polycarbonate, UV-resistant
    • Brand Name: SIEMENS
    • Usage: Industrial
    • Protection class: IP65
    • Mounting: The SICAM FSI is clamped onto the overhead line via the hotstick.
    more..
  • fault indicator

    fault indicator

    Get Price Quote

    • Power Supply: 90 to 275 VAC/DC others on request
    • Size: 96(H)*96(W)*75(D) in mm
    • Weight: 200 gms, Approx
    • Optional Input: 230VAC, 110VAC, 12VDC or 24VDC etc
    • Number of Inputs: 8
    • Operating temp: 5-50 Deg C
    • Enclosure: ABS Plastic
    • Panel Cutout: 91(H)*91(W) in mm
    more..
  • fault passage indicator

    fault passage indicator

    Get Price Quote

    SICAM Fault Passage Indicator (FPI) is a device that is used for detection and signalling of short circuit and earth-fault on medium voltage cable networks.4 external current sensors detect the phase faults (R, Y, B) and earth-fault (E).The current sensor detects phase fault and earth-fault current based on the set current threshold detection and communicate to SICAM FPI via an optical signal.By using the rotary switch available on the individual sensor, you can set the fault current threshold for phase sensors from 200 A to 1200 A (Type 1 Series), 200 A to 800 A (Type 2 Series) and for earth sensor from 10 A to 100 A (Type 1 Series), 40 A to 300 A (Type 2 Series).When the current exceeds the set threshold level, the current sensor provides an input via plastic fibre-optic cable to SICAM FPI. In this condition, the corresponding LEDs blink. In normal operating condition, there is no LED indication.SICAM FPI is used as a fault detection and indication unit. SICAM FPI is used in the feeder and distribution automation of secondary medium-voltage systems that ranges from 10 kV to 36 kV.

    more..
  • fault passage indicator

    fault passage indicator

    Get Price Quote

    CSFPI, Fault Passage Indicator — Earth is designed to detect and indicate Earth fault on a cable system, in RMU networks with one input / open ring arrangement. The unit will indicate a fault condition when current is detected above set trip current settings. Fault current is sensed by cable mounted sensor, which gives signal to indication unit. Sensor must be mounted on screened cable and can be retrofitted on the cable.If the Earth current exceeds programmed set current for programmed response time the fault will be indicated by red flashing LED and relay contact will be activated. Reset occurs automatically by preset time passage or by a external potential free input or by recovering of 230V AC (Not a Aux. Supply) Voltage or by manually via push button. A ‘Functional Test’ can also be carried out on field by pressing for more than 8 Sec and ‘Battery Test‘ by pressing the Push button for more than 6 Sec. The sensor for earth fault detection is a summation type current sensor and it is dimensioned in such a way that if can be mounted around all three phases of the network. Programmable parameters can be set through DIP switches which are accessible by opening the Front Cover of the CSFPI indication unit. Exit (Disable) option is available for fault detection.   Benefits Self Reset in the event of momentary fault (By monitoring current after a fault) Reset through Potential free input & AC/DC voltage recovery Reset manually by push button Reset automatically by a field configurable timer (hour). FEATURES Programmable Earth fault pickup level (wide range 10A to 100A) Indication of earth-fault by blinking of Earth-fault LED Programmable response delay for Earth-fault Up-to Two potential free contacts to indicate earth»fault. (remote indication for SCADA) Various Reset option for Fault Reset  

    more..
  • fault passage indicator

    fault passage indicator

    Get Price Quote

    The main function of fault passage indicating system is to identify faults occurring in the downstream section from the point of its installation in the medium voltage system. This is achieved by continuous monitoring of voltage presence and current flow in medium voltage line. Any increase in current along with absence of voltage is signaled by the equipment. Fault condition is indicated by flashing lights in FPI; this information is sent using radio signals to the communication gateway installed nearby for onward transmission to SCADA system at the control centre through a suitable communication channel. Using this system, the utility acquires information regarding the section of the line having fault. This identification helps eliminate the patrolling of entire line for finding the fault, ultimately reducing restoration time.

    more..
  • fault passage indicator

    Get Price Quote

    We are leading manufacturer and supplier of fault passage indicator

    more..
  • fault passage indicator

    Get Price Quote

    fault passage indicator, Transmission Line Analyser, pqp energy tester

    more..
  • faulted circuit indicators

    Get Price Quote

    faulted circuit indicators

    more..
  • Underground Type Faulted Circuit Indicators

    Get Price Quote

    Underground Type Faulted Circuit Indicators, High Voltage Disconnecting Switch

    more..
  • fault passage indicator

    Get Price Quote

    fault passage indicator, gas insulated switch gears, automatic meter reading

    more..
  • fault indicator

    Get Price Quote

    fault indicator, industrial display systems, fault annunciation system

    more..
  • faulted circuit indicators

    Get Price Quote

    faulted circuit indicators, Frequency Response Analyzer, Gm Counter

    more..
  • faulted circuit indicators

    Get Price Quote

    faulted circuit indicators, high voltage cable accessories, HT Isolator

    more..
  • fault passage indicator

    Get Price Quote

    fault passage indicator, lapp cables, meter reading instrument

    more..