Fire Siren
1,150 - 6,500 Per Piece
1 Piece (MOQ)
Buyers can rely on us for the best in line products as we prepare them using the finest grade raw material and modern techniques. Also, the basic material is sourced from the reliable places. In order to meet urgent and voluminous requirements of the customers, we have installed all the in-house facility at our premises. Laced with modern facilities, it helps us in securing the product line from factors like, moisture, dust, sunlight, etc. Features: Great Strength High-Durability Corrosion Resistance
Fire Siren
Get Price Quote
50 Piece (MOQ)
Best Deals from Fire Siren
Electric Fire Siren
3,500 - 5,500 Per piece
1 Piece (MOQ)
Manual Fire Siren
Get Price Quote
Our quality control strategies are carefully executed. Thus, our whole range of product is amongst the most sought-after in the industry. Whether it is a bulk or retail order, we can deliver it on time. We have transportation resources on standby all year round to ensure hassle free distribution of our product.
fire alarm siren
Get Price Quote
Explore the superlative range of the Fire Alarm Sirens offered by us. We are in association with the distinguished vendors of the markets that enable us to provide the best Fire Alarm Sirens. The offered Fire Alarm Sirens are designed using the latest technology so as to ensure efficient performance and utter compliance. Besides that, we keep nominal price quotes and can take up bulk orders as well.
Electric Fire Siren
Get Price Quote
Fire Siren
2,900 - 3,500 Per Piece
fire strobe siren
Get Price Quote
Fire Strobe Siren, 24V with supersix bright LED's; CE marking Technical Specification Sound Level : 100 db +/- 5dB (at 24VDC,1 mtr) Strobe : 8,000mcd, 6 super bright LED’s
Electric Fire Siren
Get Price Quote
ES-G1 Siren Cum Strobe
Get Price Quote
We have the latest equipment and technology for the strict checking of raw material at the initial stage only. We ensure that prior to manufacturing the material is checked on the grounds of quality. Engaged in the industry as a prominent Supplier of ES-G1 Siren Cum Strobe, we present the finest range of products.
Industrial Fire Alarm Siren
2,200 Per Piece(s)
1 Piece(s) (MOQ)
System Components Extra as applicable Alarm Volume upto 1 km Usage/Application for Alarm & Emergency Current 220 v Body Material Aluminium Color Red & Grey Material Casting Brand National Voltage 220-240 V Alarm Range 1 km Reset Time 10 sec Warranty 1 Year Industrial Hooter 1 Km Range Works on 220V AC has Loud Sound Generated using Motor Should not be used continuously for more than 30 seconds. Additional Information: Item Code: IndHoot1KM Production Capacity: As per order Delivery Time: As per order Packaging Details: Box Packing
Electric Fire Siren
Get Price Quote
fire strobe siren
3,000 Per Piece
Wireless Sounders and Strobe Sirens
Get Price Quote
Power supply: AC 220V and battery powered*. Current consumption: 70μA (sounder off) Ambient temperature: -10°C to +55°C Dimensions W × H × D 108 × 108 × 95 (mm)* Weight 255g
Fire Siren
999 Per Piece
Fire Siren
3,200 Per
fire alarm horns
Get Price Quote
Siren Beacon
10 - 11 Per Piece
06 Piece(s) (MOQ)
fire alarm siren
Get Price Quote
Audible Alarm Signals Audible fire alarm signals must provide a clear warning of a fire to all those for whom the signal is intended. For category M an L systems this would normally imply all occupants of a building, however in some sites this may not apply, for example in hospitals or rest homes, residents might need assistance to evacuate, in which case it may be sufficient to alert staff.The general requirement for the volume of audible alarm signals is that they should provide a Sound Pressure Level (SPL) of at least 65dB(A), but not more than 120dB(A) throughout all accessible areas of building.Exceptions to this general rule are as follows:In stairways the SPL may be reduced to 60dB(A)Enclosures less than 60m² may be reduced to 60dB(A)There is no minimum for enclosed areas less than 1 m²At specific points of limited extent the SPL may be reduced to 60dB(A)Where a continuous background noise level greater the 60dB(A) is present the fire alarm signal should be 5dB above the ambient, but not greater than 120dB(A).Where the alarm is intended to wake people, an SPL of 75dB(A) is required at the bed head. Generally this will require a sounder to be place within the room.Where it is not possible to place a sounder within a room, there will be a loss of approximately 20dB(A) through a standard door, and 30dB(A) through a fire door.Warning: Volumes greater than 120dB(A) will cause damage to hearing.In Open Space, as the distance from a sounder doubles, the sound level will be reduced by 6dB(A).It is Preferable to use multiple quieter sounders to achieve the required sound level, rather than a smaller number of loud devices. This is to prevent points of excessive volume, which may lead to disorientation or damage to hearing. Two sounder providing equal sound levels will combine to add 3dB(A) to the SPL.Visual alarms are required in order to satisfy the Disability Discrimination Act (DDA) as well as being used in areas of high background noise where hearing protection is likely to be worn. Just as audible alarms should be placed through all accessible areas of a building, visual alarms should be placed such that they can be seen in order to alert the hearing impaired.Visual alarms should be clearly distinguishable from other warning lights, preferably red and should flash at a rate of 30 to 130 flashes per minute. The recommended mounting height is above 2.1m; however they should not be mounted closer than 150mm from the ceiling. They should be positioned so that any alarm is clearly visible from all locations within the area protected.
Fire Siren Controller
28,500 Per Piece