Trafag Gas Density Monitor
13,000 Per Piece
100 Piece (MOQ)
FIXED-GAS-MONITOR
Get Price Quote
Model 2620 single channel digital control modules are designed to supervise and display the status of a single integral or remote (2620 R) sensor assembly. Model 2620 is housed in a NEMA AX wall mount enclosure or Ex- proof enclosure. Model 2620R Single Channel controllers interface with industry standard two or three wire 4-20 mA sensor or other standard voltage / current sensor transmitters and provide the user with concentration display and two independent adjustable alarm levels. The 3 J4 digit LCD or Alphanumeric LCD display can read the concentration. LEDs on the front panel provide indication of all three alarms. The alarm relays can be programmed to be either latching or non-latching and to activate either as a rising or failing alarm. The relays are SPDT Form C type rated at 5 Amps, to provide direct alarm action, reducing the need for interposing relays. Local Alarm devices can be connected to the configurable on board alarms. The Fail Safe Supervisory provides a reliable indication that the Monitor is fully operational. I he "hail Safe" design monitors the input power and status of the power supply for the amplifiers. A failure of any one of these functions illuminates a "Fault" Light Emitting Diode. The HEART of any Analytical system is the SENSOR. It is the most critical component in overall system performance. Because no single sensor technology is ideal for all applications, ENDEE offers TEN different sensor technologies. This capability is mandatory in today's complex industrial market. Command of each of these technologies enables us to "FITTHE PRODUCTTO THE APPLICATION", and assure long-term service and reliability & optimal performance in every application. The Monitor is a Single Gas Multi-purpose monitor that combines simplicity and high performance in a low cost low maintenance package. The rugged NEMA 4X or 7X assembly is suitable for a variety of industrial, commercial and general purpose applications to monitor HAZARDOUS,Toxic gases or Oxygen iri Process Fuel Gas or Ambient Air. Fast and accurate response. Long Life Applications Specific Gas Sensor Tech. Solid State Electronics Continuous Monitoring Two Alarm Levels Fail Safe Protection Recorder Output Integra or Remote Sensing Sensor Un-attended Operation Sampling by Diffusion or sample Draw Pump. Flexibility to fit your application needs Interfaces with Industry Standard Transmitters. The HEART of any Analytical system is the SENSOR. It is the most critical component in overall system performance. Because no single sensor technology is ideal for all applications, ENDEE offers TEN different sensor technologies. This capability is mandatory in today's complex industrial market. Command of each of these technologies enables us to "FITTHE PRODUCTTO THE APPLICATION", and assure long-term service and reliability & optimal performance in every application.
Best Deals from Fixed Gas Monitor
Fixed Gas Monitor
Get Price Quote
fixed gas monitor Electrical Measuring Instruments – Multimeter, Voltage Detector, Insulation Tester, Earth Tester, Portable Appliance Tester, Leakage Clamp meter, Low resistance Ohm-meter, Loop tester, Multifunction tester, Motor & Phase Rotation Tester, RCD Tester, Loop Tester… Dielectric Oil Test Set Flue Gas Analyser Combustion Analyser Gas Leak Detector Fixed Gas Monitor Indoor Environment Air Quality Monitor Thermal Imager
Fixed Gas Monitors
Get Price Quote
We are offering fixed gas monitors nationwide. The efficiency of the fixed gas monitors consist clarity in digital displays that transparently depicts the necessary information as per your requirement. We are offering these fixed gas monitors in different shapes, sizes and colors. We want you to select the best place to invest. features available as common card designdurablelong time usesensitiveeasy maintenance uses detectorprovides protectiondepict able fixed single / multi gas monitoring the fixed monitoring system consists of two parts : monitoring model gazalarmsensing model gazsens model gazalarm the monitoring unit consists of power supply card : size - 220 mm x 100 mm supplies power (9 v dc to 24 v dc) to complete system including gas detector assembly (field unit) with a current carrying capacity of one card is maximum up to 5 amp. This can cater up to 10 cards in one rack. Multiple numbers of cards in multiple numbers of racks in one panel can be provided if the numbers of channels are more than ten.control card : control card provides fixed voltage & current required to the field unit. It also accepts 4-20 ma signal from field unit. This signal is then processed by control card using instrumentation amplifier. The processed signal corresponding to the gas concentration available in the field is displayed by two or three digit 7 segments led on control card display section. Two level alarms (latching/non latching type) are generated if the gas concentration is above preset limit. Fault alarm also is provided on the control card in case of sensor open/ short, cable from sensor is open/ short & under range/ over range conditions appear. The control card also delivers 4-20 ma.(repeater) output signal for plc / dcs.facility card : this card receives the alarm condition signal from control card. Depending upon the alarm conditions it activates the relays mounted on it & hoots the buzzer or siren or sends control signal to the pre-desired device. It also consists of alarm accep, reset & lamp test conditions. The push buttons are provided on the fascia plate to achieve the desired job.mother board : this board is provided on the back of 19” rack. The mother board pcb is provided with the copper tracks & euro connectors to hold all the cards like control card, power supply card & facility card. With the help of proper design reduces the back panel wiring of all cards..
Fixed Online Gas Detection module
Get Price Quote
The RAEGuard EC is a permanently mounted (fixed) toxic gas or oxygen sensor/transmitter that operates from a 9 to 36 VDC power source and provides an analog (4 to 20mA) and digital (RS-485) signal output. Housed in an explosion-proof enclosure, the RAEGuard EC is equipped with a local digital display of the gas concentration and function keys for performing calibration. The RAEGuard EC is operated with a standard 4 to 20mA/RS-485 controller or as a stand-alone sensor module.
Fixed Dual Channel Gas Monitor
22,000 Per Piece
10 Piece (MOQ)
Fixed Gas Monitor
17,500 Per Piece
IR SENSOR FIXED GAS DETECTOR
Get Price Quote
These single-gas, multi-gas, PID monitors, controllers, and wireless alarm bar can be installed to provide continuous, always-on monitoring for toxic gases and gamma radiation. Gas Detector Features no false alarms utilizing stable, field-proven sensor technologies Highly selective for specified target Gas No zero drifts with changes in ambient conditions Self-Calibration adjusts span based on sensor life curve Non-Intrusive field Calibration using magnet LCD display: 12 characters x 2 lines. Provides user interface with magnetic switches Not affected by temperature -40 deg. C to +50 deg. C Offsite sensor calibration with sensor embedded memory chip Peak value, 15-min. , Remaining Sensor Life, Replace Sensor indication and number of days since last gas calibration Optional Relay Module in same enclosure with low, mid, high and fault relays; rated 10 Amps. Gas alarm relays can be programmed latching or non-latching, energized or non-energized, time delays Available suitable for SIL 2 environments Continuous Advanced Diagnostics Sensor Technology Electrochemical, Photo-Ionization,Catalytic, Infrared, Solid-State Detection Range Varies with gas type Resolution 0.01 ppm; 0.1 ppm; 1 ppm;0.1 %Volume; 1 %LEL(depends on gas type) Response Timeless than 30 sec. 90% Recovery Timeless than 30 sec. 10% Temperature Range-40 deg. C to +50 deg. C Humidity Range10 - 90% RH, non-condensing Zero Driftless than 1% of full-scale typical Power Requirements12-30 VDC 1.08 - 1.82 W (24 VDC) Outputs4-20 mA Standard Modbus RTU Option Relay Module Option Sensor Service Life>2 years typical under normal conditions, depends on sensortype and conditions
Fixed Gas Monitor
Get Price Quote
Fixed Gas Monitor, Dew Point Meter, Water Quality Monitors
Fixed Gas Monitors
Get Price Quote
Fixed Gas Monitors, Nagman 14+ Temperature Calibrator
Fixed Gas Monitor
Get Price Quote
Fixed Gas Monitor, Frequency Response Analyzer, Gm Counter
Fixed Gas Monitor
Get Price Quote
Fixed Gas Monitor, bitumen drum filling system, FRLS Flamegard Wires