Fume Hood
Get Price Quote
1 piece (MOQ)
Thick Wooden Board Fabricated, Outer is Finished with Laminated Mica and Inner Duly painted, Designed So as Throw Out all Toxic/harmful Vapors, Thus Protecting Costly instruments and the Person Working in the Lab. Working Table Top is Fitted With stainless Steel Top, Provided with Ss Sink and Tap. the Front Door Moves Vertically up & Down with Concealed Counterbalanced Weight/by Hingers the Unit is Fitted with Flourescent Light and a Gas Cock For gas/air Supply. the Space Under the Work Station Can Be Provided with Switches For exhaust System and Flourescent Lights. Workable On 220 Volts Ac Supply. working Size 2'x2'x2' 4'x2'x2' 6'x2'x2' 5'x3'x3' 7'x3'x3' optional Accessories : pvc Fume Duct per frp/ss Lining Onworking Walls
Platform Mounted Fume Hood
1 - 2 Per Piece
1 Piece (MOQ)
We are the prime Manufacturer and Exporter of the Platform Mounted Fume Hood, which is popular among clients for ensuring safety and results. Our Platform Mounted Fume Hoods are carefully designed by the experts, keeping varied requirements of clients in mind that make their demand consistent in the global markets. Why Our Platform Mounted Fume Hood ? Directly mounts on RCC platform Available For Easy use for daily purpose Non-standard fume hood Designed in conformity with the industry standards Ensure safety and inspected annually Robust construction Resistant to Water Fumes Termites Spacious Minimum maintenance Used For Safe handling of harmful or toxic fumes of vapors Capturing, containing, and removing contaminants Preventing contaminants escape into the laboratory Applications Biotech labs Pharmaceutical labs Educational institutes Chemical industry Research centers Paint and oil industry
Best Deals from Fume Hood
Fume Hood
Get Price Quote
10 Piece (MOQ)
AAS ICP Fume Hood
30,000 - 45,000 Per Piece
1 Piece (MOQ)
Details AAS/ICP deliver toxic fumes which needs to be exhaust outside the laboratory Fume Hood help for fumes exhaust outside the lab. Through Blower/Impeller MOC: SS304 fume hood canopy & ducting Capacity: As per Instrument & ducting Length. Standard supply 10 Ft. Length
PP Fume Hood
Get Price Quote
1 Piece (MOQ)
Laboratory Fume Hood
100,000 Per Piece
1 Piece (MOQ)
Kitchen Fume Exhaust Hood
24,000 Per Piece
1 Piece (MOQ)
Mild Steel Fume Hood
135,000 Per Piece
1 Piece (MOQ)
Stainless Steel Fume Hood
Get Price Quote
100 Piece (MOQ)
FUME HOOD Working table top is fitted with black Granite/SS 304 Grade and three side wall304 Grade SS sheet a small wash basin with connections provided for inlet and outlet of water. The outer Body is made of MS powder coated The front door moves vertically up and down with concealed counter balanced weight. The unit is fitted with fluorescent light and a gas and water tap supply. The space under the work station provided with storage compartments for storage purpose. The front facing panel is fitted with 15/5 Amp socket with switches for exhaust system and fluorescent light. Unit is provided with Plastic Elbow for Air outlet to connected to Suction system at site The suction system works on centrifugal blower TO WORK ON 220/230 volts A.C. Supply. Outer Size 910 mm x 750 x 1800mm Height; Other clean room equipments include - Laminar air flow, Fume Hood stainless steel, Cage Changing Hoods.Glove Boxes. Stain less steel mopping trolley, Biological Safety Cabinets, HEPA Filters, pass box ss, Stainless steel chairs ss made, Sampling kit for pharma, Trolley ss for pharma labs, Garment cubicle ss with uv light, lockers for labs changing rooms, Garment bin ss for labs, Mirrors ss for changing room pharma Companies.
Zexter Fume Hood
74,500 Per Nos
1 Nos (MOQ)
Product Overview: Our chemical fume hoods are conceptualized and designed to provide a work area which is free from all the potentially hazardous fumes or chemical effluents that may be emitted during the course of a given experiment or procedure in a laboratory. Our fume hoods capture the fumes released during an experiment by drawing fresh air from the environment, past the user into the unit.. This way the concentration of the chemical fumes/effluents are kept at the minimum possible levels in and around the breathing zone of the user. The vector of the air in the fume hood points to the inward direction and perpendicular to the face of the user. The velocity of the air is controlled at approximately 80 feet per minute, so as to control the particle kinetics of various aerosols and diffused gases. Features: Ergonomic Design Energy Efficient Mechanism Low Noise Levels Conforms To ASHRAE-110-1995 (British Standard) Testing Method. Construction Details: Our fume hoods are developed to be used as semi closed ventilated enclosures so as to protect the user from harmful and toxic fumes and vapors and to eliminate the possibility of accidental fire, which may be resulted due to the emission of inflammable gases during the course of a given experiment. Hence the material of construction of all our fume hoods are carefully chosen S.S-316 grade/ M.S duly Powder Coated. The work table is made of heavy gauges SS-316. Our entire fume hoods are provided with sliding sash made out of special grade shatter proof temper glass duly framed in aluminum frame with sliding motion and counter weight balanced mechanism. Our units ensure minimum illumination level of approx 800 lux on the work table. The unit is equipped very diligent heavy duty exhaust system, comprising of dynamically balanced centrifugal impeller with high speed motor of approx 1440 RPM (Heavy Duty 1/4 H.P A.C Motor/ 1/2 H.P A.C Motor/ 1 H.P A.C Motor/ 1.5 H.P A.C Motor ).
Fume Hood
Get Price Quote
1 Piece (MOQ)
“TEMPO” make fume hood is a type of local ventilation device that is designed to limit exposure to hazardous or toxic fumes, vapours or dust. Air is drawn from lab space into the fume hood then dispersed via a pipe to the outside atmosphere. Basically, it protects the user from inhaling toxic gases. Application Chemical lab Food manufacturer Drugs manufacturer company Paint manufacturing company Rubber industry Polymer industry Cement industry Construction Exhaust system Centrifugal blower with anti coregent coating Low noise blower Material of construction Double wall construction Inner body PP and outer body MS powder coated Inner body fibre and outer body MS powder coated Smooth black granite table Features Electrical socket Thich toughen glass window Vertical opening Sash Fluorescent lamp Centrifugal blower with Anti coregent coating Optional Features Tap for gas Tap for water Sink for water Castor wheels Storage cabinet at bottom PVC ducting pipe
FRP Fume Hood
Get Price Quote
Fume Exhaust Hood
108,000 - 270,000 Per Piece
1 Unit (MOQ)
Fume Hood
Get Price Quote
1 Piece (MOQ)
SIS-1315 Laboratory fume hoods are one of the most important components used to protect laboratory personal from exposure to hazardous chemicals and agents used in the laboratory. When used properly, they exhaust toxic, offensive or flammable materials when the containment of an experiment or procedure fails and vapors or dust escape from the apparatus being used. Cabinet is made of Thick Ply Board / M.S Duly Powder Coated / Stainless Steel (304). Interiors coated with Asbestos / Lead sheets and further coated with fire proof epoxy paint. Working table upto 2 feet is covered with Glazed Ceramic Acid resistant tiles. Working table is covered with Granite/Tiles / S.S. 304. Front door is made of 6mm clear toughened glass. Counter weight balance front door . Vertical sliding facility & the front door can be stopped at any point. Exhaust blower consists of single phase motor which is enclosed in a wooden casing connected with a PVC Exhaust Ducting. OPTIONS:- Base Storage Cabinet & Fire Proof Tiles Stainless Steel Sink (Wash Basin) with water inlet outlet system Working Size:2’x2’x2’3’x2’x2’4’x2’x2’6’x2’x2’8’x2’x2’ Or ANY NON STANDARD SIZE
ductless fume hood
70,000 Per Piece
1 Piece (MOQ)
Fume Hood
Get Price Quote
Bench Top Fume Hood
150,000 - 175,000 Per piece
1 PIECE (MOQ)
Laboratory Fume Hood
115,000 Per Piece
1 Piece (MOQ)
Fume Hood
Get Price Quote
1 Piece (MOQ)
Volume Of ExhaustOur fume hoods are capable of maintaining a constant exhaust volume. The maximum variation permissible due to baffle adjustment, in our in house test procedure is 6% of the given volume of exhaust.Pressure (Static)Our fume hoods are designed to minimize the loss of static pressure at a given baffle opening position.Noise/Sound LevelsOur fume hoods are designed to generate lower noise levels. The performance of our fume hoods are rated better than the industry standards of 75 db, at approximately 15 cm distance from the sash.Sash Counter Balance SystemsChain & Sprocket Systems - Typically a hardened chain (similar to a bicycle chain) runs over pockets to the counterweight.The sprockets are attached onto a single axle which allows them to turn at the same time.This system will travel smoothly no matter where the user chooses to lift the sash along the hood width. This is especially important on longer hoods where the user may be lifting the sash at one end.FRP Generally Used For Highly Toxic Chemicals Like Sulphuric Acid, Hydrochloric Acid, Nitric Acid Are Using In Fume Hood.