Long Body Single Phase Solid State Relays
Get Price Quote
ADR131A Ashida Earth Fault Relay
15,000 Per Piece
1 Piece (MOQ)
Best Deals from Ground & Phase Protection Relay
Cable Fault Locator
445,000 Per Piece
1 Piece (MOQ)
PSCS Single Phase Switch
9,500 Per Piece
1 Piece(s) (MOQ)
real time clock:programmable street light control switch has in built real time clock with battery backup sufficient for five years minimum. It displays the day and date along with on and off time, on led display and maintain the timing accuracy of ± 1 (one) second over the entire range of environmental operating conditions. programming features: switch on and off the streetlight loads, at rated power factor at pre-determined time. have facilities of default program (company installed)based on “astronomical timer” means daily change of program as per sun rise and sunset timing, as well as pre- defined (user programmable) to pre-program and switch the on and off time for one year with minimum 12 programs, spread over a year. streetlight on / off timing accuracy is maintained within 60 seconds from preset time under the entire range of environment conditions. facilities to switch on/off the streetlight loads, manually by-passing the programmed circuit. protection: over voltage / under voltage: have protection from over voltage i.e. Load switch off when voltage goes above 260±5v (adjustable at factory end) and auto restart when normal voltage is sensed i.e. 250±5v. have protection form under voltage i.e. Load switch off when voltage goes below 160±5v (adjustable at factory end) and auto restart when normal voltage is sensed i.e. 180±5v. over load and short circuit protection:
cable locator
320,000 Per Piece
Single Phase Digital Current Protection Relay (Din Rail)
1,300 Per piece
01 piece (MOQ)
Pipe Cable Locator EP-Tech Canada
Get Price Quote
Sophisticated Electronic Receiver is equipped with a search coil and able detect coated pipeline signal for a great long distance by using null method theory. Transmitter conductively connected to the pipe by a remote ground and equipped with Interruption mode to eliminate noise and stray currents. The Transmitter has different output levels to match the impedance to all soil conditions.
phase failure relays
Get Price Quote
We are a prime Distributor of Phase Failure Relays, based in Andhra Pradesh. These relays are suitable for monitoring incoming 3-phase supply from Mains (Electricity distribution line). Being independent of load, they can be used for any HP/KW rating of load.
Over Current Earth Fault Relay
11,500 Per Piece
1 Piece(s) (MOQ)
We are the exporter and supplier of this products.
fault passage indicator
Get Price Quote
Fault Passage Indicators are useful for Failure Detecting and Condition-Monitoring in Power-Distribution Networks. The main function of fault passage indicating system is to identify faults occurring in the downstream section from the point of its installation in the medium voltage system. This is achieved by continuous monttoring of voltage presence and current flow In medium voltage line. Features : Permanent Earth-faults : Indication of permanent earth-faults by double blinking of the Earth fault LED. 2nd short-circuit pass-through : Indication of a second short-circuit passing through by double blinking of the respective short-circuit LED Separate fault response delays: The fault response delay for short-circuits & earth-faults can be adjusted individually. Optional three relay contacts: The indicator can be equipped with two remote contact relays to indicate earth-faults and short-circuits separately and one contact for FPI healthy on battery. Optional power supplies : 24 V DC power supply wlth lithium rechargeable battery backup. Specification : SHEET Adjustable phase to phase short-circuit trip current 200/ 400/ 500/ 600/ 800/1000A (+-10 %) Adjustable phase to phase Earth-fault tip current :10/ 20 /40 / 60 / 80 /100 * A (+-10 %) Adjustable short circuit response delay time 80 / 100 / 120 / 160 *ms Adjustable earth fault response delay earth-fault adjustable: 80 /100 /120 /160 * ms Indications Red Indication for short circuit and earth fault and yellow for battery low Manual push button Is provided to Reset of the Indicator On site function test Protection class; CT's IP67 EMI according to IEC 1000-4-2, IEC 1000-4-3 Operation temperature range -25°C to +70°C SCADA contact - 1 - Change-over contact 2-Optional NO contact for separate earth-fault and short-circuit indication 3 - Permanent/ wipe contact can be selected on site by a dip switch, time 100 m sec max. 230 V AC/ max. 2 A / max. 30 W.
Fiber Optic Visual Fault Locator 5wm,10wm, 20wm, 30wm
700 - 1,800 Per piece
10 piece (MOQ)
Rechargeable optical power meter maximum wave length 1650 nm Wavelength to 850 Nm With 10 Wavelength Optical Power Range -50 dbm To +26dbm VFL:10 mw
Underground Cable Fault Locator
1,000,000 Per piece
1 p (MOQ)
Solve these problems with the new RD8200. Designed with the operator in mind, it is our most advanced and capable range of precision locators.
Overcurrent & Earth Fault Protection IDMT Relay
Get Price Quote
-1 Piece(s) (MOQ)
Cable Fault Locator
8,000 Per Piece
We are Offering Cable Fault Locator.We are Offering Cable Fault Locator.We are Offering Cable Fault Locator.We are Offering Cable Fault Locator.We are Offering Cable Fault Locator.
Ground Fault Monitoring System
Get Price Quote
At Neelkanth you will get the best ground fault monitoring system Mumbai at an affordable price. We are a reliable and trusted manufacturer and supplier of electrical devices that are required in different sectors. When planning for electrical system protection, the ground faults present far more common and in aggregate potentially more dangerous occurrences for personnel and the equipment that are used. Bonding, grounding and ground fault protection are extremely vital for reducing the hazards of electrical shocks to the personnel during a ground fault like when a current carrying conducting insulator fails or inadvertently faults to the ground. Choosing our products for ground fault protection will allow the electrical system to stay maintained and in a reliable manner matching the needs or loads that it serves to isolate undesirable fault conditions In a quick and ideally selective way. Why Choose Us? Our products are tested and certified by experts. These are made with advanced machines and technologies and helps in ground fault protection for specific equipment like transformers, generators, motors and much more. A ground fault usually occurs when the conductor at a voltage other than the earth reference comes in contact with another conductive material that is connected to the ground. Depending on those of the installed grounding system, this can lead to the sustained or transient overvoltage and under-voltage to an undesirable single like to the ground fault currents. These faults can often harm the systems and cause event losses. This is the reason why choosing our products is the best choice for different customers and clients. Following are some more reasons why you should choose our products and use them for detecting ground faults. • Provides you with a common reference point • Improves safety • Protects your equipment in the best way possible • Ground fault locations can be detected easily • Allows you better control of transient overvoltages • Electrostatic accidents can be better avoided We have a micro-controlled based ground fault detector in our company as well. Choose us and get our products today.
Cable Fault Locator
Get Price Quote
We have own cable fault locating kit & excellent testing engineer for fault locating of under ground control & power cable up to 33KV.
Cable Fault Locator
Get Price Quote
underground Live cable locator
150,000 - 180,000 Per
01 Box (MOQ)
We are pioneers in the manufacturing since 2011 and only one to offer unprecedented warranty of 5 years on our products A) Underground Live Cable Locator, Pacetrace P700 a) It is the most simplest ever, b) It is the ONLY ONE to have a penetration of 5 metres of underground depth c) Without any fancy and hence complicated features like transmitter and receiver for which we have to find the starting point of the cable(which is not possible to find generally) to transmit and receive the signal. d) The decibel of the buzz depends upon the magnitude of current. More the current, shriller is the buzz. e) Unlike the above you can start detecting the cable from any point in the middle of the road. You need not search for the starting point. Just walk with the Locator ON moving right and left; if you hear the beep, the cable lies just under the sensor. Is it not simple? It is as easy as walk in the park. Easy to operate and easier to maintain. It has zero maintenance! It can map underground cable network in factory premises without any excavation; which will be useful for laying new cable underground safely in future.
Voltage Miniature Relay
Get Price Quote
3.5VA Model Name/Number: Os-ex-2g /We77/Ex-eru(eru) Osna Smart Tanker Earthing Relay, Wall Mounted,
45,000 - 55,000 Per piece
1 Piece (MOQ)
Earth Fault Relay
Get Price Quote
Prok devices pvt ltd an iso 9001-2008 company introduces digital microprocessor micro controller based idmt definite time instantaneous earth fault relay (efr). It is a current sensing device which is semitropical professionally designed and tested for protection of generators, transformers and feeders. Prok dv's make digital microprocessor micro controller based idmt definite time instantaneous earth fault relay (efr) can be employed with various earth fault protective schemes
Earth Leakage Relay
Get Price Quote
Cable Fault Locator
Get Price Quote
We are offering cable fault locator we have great pleasure to inform to you, we provide complete set of equipments in the field of cable laying projects. Along with the same, as we discussed, we also deal in fault detection for u/g & o/h lines with pre warning facilities on the live line before the actual fault occurs & various testing equipments for electrical parameters on hv transformers, cables, ct, pt, gis, etc. Van mounted with all in one set of equipments.
8KV Cable Fault Locator
Get Price Quote
1 Piece (MOQ)
STATOR EARTH FAULT PROTECTION FOR GENERATORS BY 20HZ INJECTION METHOD
Get Price Quote
1 piece (MOQ)
In order to implement a 100 % stator earth fault protection based on sub harmonic injection, a 20Hz voltage is injected into the generator star point. The 20-Hz generator SGEN-1001 is used in combination with the band pass filter SBPF-1001 in the Stator Earth fault protection. Injection can be performed by connecting the SGEN-1001 and the SBPF-1001 to the load resistor of an earthing or neutral transformer. If an earth fault occurs in the generator star point, the 20 Hz voltage drives a current through the fault resistance. From the driving voltage and the fault current, the protective relay determines the fault resistance.
Overcurrent & Earth Fault Protection IDMT Relay,
Get Price Quote
1 Pack (MOQ)
Miniature Power Relay
Get Price Quote
Single Phase Protection Relay
Get Price Quote
Protection of induction motors against single phasing or reverse phasing or unbalance supply is one of the major problems in electrical systems. For safe running of 3-phase motors, special protections that keep a continuous watch on supply conditions are very essentials. The major cause of maxium motors burn-out is overloading which occurs due to unbalance supply or single phasing. Phase failure occurs in case of fuse blown-off, loose connections or loss of phase from supply itself.
Definite Time Earth Leakage Relay
100 - 19,219 Per
1 Piece (MOQ)
Features Bar graph indication of leakage current Remote reset and test facility Wide range of settings Low burden Principle of Operation: JRC 974 provides earth leakage protection for power systems. The relay operating time is determined by a programmable definite time delay. The relay measures the earth leakage current from the CBCT and if it exceeds the set threshold, it extends a trip signal after the operating time. The relay output contacts are self reset type. TEST button facilitates verification of relay contacts.
Earth Fault Relay
1,799 Per Piece