Ground & Phase Protection Relay Dealers

(445 products available)
  • Long Body Single Phase Solid State Relays

    Long Body Single Phase Solid State Relays

    Get Price Quote

    • Material: Aluminium, Plastic
    • Certification: CE Certified
    • Color: Metallic, Black
    • Voltage: 110V, 220V
    • Frequency: 60Hz
    • Warranty: 1yr
    • Current Type: AC, DC
    • Type: Solid State Relays
    • Application: Industrial Use
    • Feature: Accuracy, Auto Controller, Dipped In Epoxy Resin, Durable, Heat Resistance, High Performance
    more..
  • ADR131A Ashida Earth Fault Relay

    ADR131A Ashida Earth Fault Relay

    15,000 Per Piece

    1 Piece (MOQ)

    • Country of Origin: India
    • Switching Voltage For Zero: 415 V
    • Finishing: Polished
    • Phase: Single Phase
    • Warranty: 1 Year
    • Number of Poles: 4 Pole
    • Brand Name: Ashida
    • Current: 10 Amp
    more..
  • Best Deals from Ground & Phase Protection Relay

  • Cable Fault Locator

    Cable Fault Locator

    445,000 Per Piece

    1 Piece (MOQ)

    • Color: Yellow
    • Power Source: Electric
    • Application: Industrial Use,Underground Fault Locator
    • Feature: Proper Working, Superior Finish
    • Frequency: 50Hz
    • Country of Origin: India
    • Operation Temperature: -15 DegreeC
    • Weight: 1.20 KG
    more..
  • PSCS Single Phase Switch

    PSCS Single Phase Switch

    9,500 Per Piece

    1 Piece(s) (MOQ)

    • Type: Single Phase Switch, Real Time Systems
    • Shape: Rectangular
    • Condition: New
    • Rated Power: 5KW
    • Driven Type: Electric
    • Phase: Single Phase
    • Warranty: 1Years
    • Certifications: ISO 9001:2008
    • Country of Origin: India

    real time clock:programmable street light control switch has in built real time clock with battery backup sufficient for five years minimum. It displays the day and date along with on and off time, on led display and maintain the timing accuracy of ± 1 (one) second over the entire range of environmental operating conditions. programming features: switch on and off the streetlight loads, at rated power factor at pre-determined time. have facilities of default program (company installed)based on “astronomical timer” means daily change of program as per sun rise and sunset timing, as well as pre- defined (user programmable) to pre-program and switch the on and off time for one year with minimum 12 programs, spread over a year. streetlight on / off timing accuracy is maintained within 60 seconds from preset time under the entire range of environment conditions.  facilities to switch on/off the streetlight loads, manually by-passing the programmed circuit.   protection: over voltage / under voltage: have protection from over voltage i.e. Load switch off when voltage goes above 260±5v (adjustable at factory end) and auto restart when normal voltage is sensed i.e. 250±5v. have protection form under voltage i.e. Load switch off when voltage goes below 160±5v (adjustable at factory end) and auto restart when normal voltage is sensed i.e. 180±5v. over load and short circuit protection:

    more..
  • cable locator

    cable locator

    320,000 Per Piece

    • Operating Temperature: -20 + 60 deg C
    • Brand: Technoac
    • Model: CBI-309N
    • Maximum Measured Depth: 9,9 meters
    • Depth Measurement Accuracy: +-5%
    • Utility Location Accuracy: +-5%
    • Max Gain Factor: 120 dB
    • Sensitivity: mkA at 1m distance (at 33 kHz)
    • Display: LCD display, 320x240 pix., with LED backlight
    • Operation Time: 20 hrs
    • Dimensions: 330 x 140 x 700 mm
    • Weight: 2.4 Kg
    more..
  • Single Phase Digital Current Protection Relay (Din Rail)

    Single Phase Digital Current Protection Relay (Din Rail)

    1,300 Per piece

    01 piece (MOQ)

    • Brand Name: MISTURA
    • Material: Plastic
    • Current Type: AC
    • Shape: Square
    • Color: Black
    • Condition: New
    • Voltage: 220V
    • Mounting Type: Din Rail Mounting
    • Specialities: Stable Performance, High Performance, Durable
    • Phase: Single Phase
    • Warranty: 1 Year
    • Country of Origin: India
    • Overall Weight: 200gm
    more..
  • Pipe Cable Locator EP-Tech Canada

    Pipe Cable Locator EP-Tech Canada

    Get Price Quote

    • 32 Watt Dual transmitter frequency: 745 HZ and 4Hz

    Sophisticated Electronic Receiver is equipped with a search coil and able detect coated pipeline signal for a great long distance by using null method theory. Transmitter conductively connected to the pipe by a remote ground and equipped with Interruption mode to eliminate noise and stray currents. The Transmitter has different output levels to match the impedance to all soil conditions.

    more..
  • phase failure relays

    phase failure relays

    Get Price Quote

    • Material: Plastic
    • Certification: CE Certified
    • Voltage: 220V
    • Frequency: 50Hz
    • Warranty: 1Year
    • Weight: 1-2kg
    • Application: Industrial
    • Power: 3-6kw

    We are a prime Distributor of Phase Failure Relays, based in Andhra Pradesh. These relays are suitable for monitoring incoming 3-phase supply from Mains (Electricity distribution line). Being independent of load, they can be used for any HP/KW rating of load.

    more..
  • Over Current Earth Fault Relay

    Over Current Earth Fault Relay

    11,500 Per Piece

    1 Piece(s) (MOQ)

    • Frequency: 50 Hz
    • Number of Poles: 2 Pole
    • Phase: Three Phase
    • Relay Type: APFC Relay, Overload Relay
    • Voltage type: AC
    • Voltage: 380 - 415 V

    We are the exporter and supplier of this products.

    more..
  • fault passage indicator

    fault passage indicator

    Get Price Quote

    • Application: Laboratory
    • Brand Name: Powerinst
    • Voltage: 240 V
    • Frequency: 50 Hz
    • Packaging Type: Carton Box
    • Country of Origin: Made in India

    Fault Passage Indicators are useful for Failure Detecting and Condition-Monitoring in Power-Distribution Networks. The main function of fault passage indicating system is to identify faults occurring in the downstream section from the point of its installation in the medium voltage system. This is achieved by continuous monttoring of voltage presence and current flow In medium voltage line.   Features : Permanent Earth-faults : Indication of permanent earth-faults by double blinking of the Earth fault LED. 2nd short-circuit pass-through : Indication of a second short-circuit passing through by double blinking of the respective short-circuit LED Separate fault response delays: The fault response delay for short-circuits & earth-faults can be adjusted individually. Optional three relay contacts: The indicator can be equipped with two remote contact relays to indicate earth-faults and short-circuits separately and one contact for FPI healthy on battery. Optional power supplies : 24 V DC power supply wlth lithium rechargeable battery backup.   Specification : SHEET Adjustable phase to phase short-circuit trip current 200/ 400/ 500/ 600/ 800/1000A (+-10 %) Adjustable phase to phase Earth-fault tip current :10/ 20 /40 / 60 / 80 /100 * A (+-10 %) Adjustable short circuit response delay time 80 / 100 / 120 / 160 *ms Adjustable earth fault response delay earth-fault adjustable: 80 /100 /120 /160 * ms Indications Red Indication for short circuit and earth fault and yellow for battery low Manual push button Is provided to Reset of the Indicator On site function test Protection class; CT's IP67 EMI according to IEC 1000-4-2, IEC 1000-4-3 Operation temperature range -25°C to +70°C SCADA contact - 1 - Change-over contact 2-Optional NO contact for separate earth-fault and short-circuit indication 3 - Permanent/ wipe contact can be selected on site by a dip switch, time 100 m sec max. 230 V AC/ max. 2 A / max. 30 W.

    more..
  • Fiber Optic Visual Fault Locator 5wm,10wm, 20wm, 30wm

    Fiber Optic Visual Fault Locator 5wm,10wm, 20wm, 30wm

    700 - 1,800 Per piece

    10 piece (MOQ)

    • Power Source: 810nm
    • Application: Optical power measure
    • Wavelegth Range: 1100-1600 nm
    • Display Type: Led
    • Number Of Selectable Wavelength: 10 Wavelength

    Rechargeable optical  power meter maximum wave length 1650 nm Wavelength to 850 Nm With 10 Wavelength Optical Power Range -50 dbm To +26dbm VFL:10 mw 

    more..
  • Underground Cable Fault Locator

    Underground Cable Fault Locator

    1,000,000 Per piece

    1 p (MOQ)

    • Brand Name: Aerica engineer
    • Color: Sky Blue
    • Condition: New
    • Automation Grade: Automatic
    • Application: Industrial Use
    • Country of Origin: India

    Solve these problems with  the new RD8200. Designed with the operator in mind,  it is our most advanced and capable range of precision locators.

    more..
  • Overcurrent & Earth Fault Protection IDMT Relay

    Overcurrent & Earth Fault Protection IDMT Relay

    Get Price Quote

    -1 Piece(s) (MOQ)

    • Packaging Type: Carton Box, Wooden Box, Metal Sheet Box
    • Overall Weight: 100gm, 200gm, 300gm
    • Usage: Factories, Power Plants, Shopping Malls
    • Specialities: Stable Performance, Shocked Proof, High Performance, Heat Resistance, Durable, Dipped In Epoxy Resin
    • Size (Inches): 4-6 Inches, 6-8 Inches, 8-10 Inches
    • Overall Dimension: 275x90x285mm, 480x190x285mm
    • Witdh: 50-80mm, 80-120mm
    • Country of Origin: India
    more..
  • Cable Fault Locator

    Cable Fault Locator

    8,000 Per Piece

    • Country of Origin: India
    • Color: Black, Brown, Creamy, Dark Brown, Grey, Ivory, Light Grey, Off White, White
    • Warranty: 1 Year, 2 Year, 5 Year
    • Frequency: 50Hz, 60Hz
    • We are Offering Cable Fault Locator.: We are Offering Cable Fault Locator.
    • Packaging Type: Box, Plastic Packet, Plastic Bag
    • Specialities: Waterproof, Rust Proof, High Acurace, Heat Resistant, Hard Structure
    • Corrosion Resistance: Yes, No
    • Rust Proof: Yes, No

    We are Offering Cable Fault Locator.We are Offering Cable Fault Locator.We are Offering Cable Fault Locator.We are Offering Cable Fault Locator.We are Offering Cable Fault Locator.

    more..
  • Ground Fault Monitoring System

    Ground Fault Monitoring System

    Get Price Quote

    • Current Setting Range: 300 mA to 12 Amps. In step - 300mA / 500mA / 750mA / 1.00A / 1.25 / 1.50 / 1.75 / 2.50 / 3.00 / 4.00 / 5.00 / 6.00 / 7.00 / 8.00 / 9.00 / 10.00 / 11.00 / 12.00
    • Tripping Time: 0.0 Second top 5 Seconds in step of 0.05 Sec
    • Instantaneous Tripping Time: less than 35 msec.
    • Core Balance Current Transformer: Moulded case CBCT with open circuit detection.
    • Communication: RS. 485 (Optional)
    • Potential Free contact: 2 Change Over Contact for Tripping and Alarm.
    • Operating Temperature: -5 to 55 C.

    At Neelkanth you will get the best ground fault monitoring system Mumbai at an affordable price. We are a reliable and trusted manufacturer and supplier of electrical devices that are required in different sectors. When planning for electrical system protection, the ground faults present far more common and in aggregate potentially more dangerous occurrences for personnel and the equipment that are used. Bonding, grounding and ground fault protection are extremely vital for reducing the hazards of electrical shocks to the personnel during a ground fault like when a current carrying conducting insulator fails or inadvertently faults to the ground. Choosing our products for ground fault protection will allow the electrical system to stay maintained and in a reliable manner matching the needs or loads that it serves to isolate undesirable fault conditions In a quick and ideally selective way. Why Choose Us? Our products are tested and certified by experts. These are made with advanced machines and technologies and helps in ground fault protection for specific equipment like transformers, generators, motors and much more. A ground fault usually occurs when the conductor at a voltage other than the earth reference comes in contact with another conductive material that is connected to the ground. Depending on those of the installed grounding system, this can lead to the sustained or transient overvoltage and under-voltage to an undesirable single like to the ground fault currents. These faults can often harm the systems and cause event losses. This is the reason why choosing our products is the best choice for different customers and clients. Following are some more reasons why you should choose our products and use them for detecting ground faults. • Provides you with a common reference point • Improves safety • Protects your equipment in the best way possible • Ground fault locations can be detected easily • Allows you better control of transient overvoltages • Electrostatic accidents can be better avoided We have a micro-controlled based ground fault detector in our company as well. Choose us and get our products today.

    more..
  • Cable Fault Locator

    Cable Fault Locator

    Get Price Quote

    We have own cable fault locating kit & excellent testing engineer for fault locating of under ground control & power cable up to 33KV.

    more..
  • Cable Fault Locator

    Cable Fault Locator

    Get Price Quote

    • Features: Consists of a transmitter and a receiver, Conductor tracing in the soil, Detecting fuses and assigning current circuits, Tracing metallic water and heating piping, Auto-Power-Off function
    more..
  • underground Live cable locator

    underground Live cable locator

    150,000 - 180,000 Per

    01 Box (MOQ)

    • Color: Grey
    • Condition: New
    • Power Source: Battery
    • Automation Grade: Automatic
    • Feature: Easy To Use
    • Operating Temperature: High Temperature
    • Type: Underground Cable Fault Locator
    • Warranty: 5years
    • Country of Origin: India

    We are pioneers in the manufacturing since 2011 and only one to offer unprecedented warranty of 5 years on our products    A) Underground Live Cable Locator, Pacetrace P700  a) It is the most simplest ever, b) It is the ONLY ONE to have a penetration of 5 metres of underground depth c) Without any fancy and hence complicated features like transmitter and receiver for which we have to find the starting  point of the cable(which is not possible to find generally) to transmit and receive the signal. d) The decibel of the buzz depends upon the magnitude of current. More the current, shriller is the buzz. e) Unlike the above you can start detecting the cable from any point in the middle of the road. You need not search for the  starting point. Just walk with the Locator ON moving right and left; if you hear the beep, the cable lies just under the sensor.  Is it not simple? It is as easy as walk in the park. Easy to operate and easier to maintain. It has zero maintenance! It can map underground cable network in factory premises without any excavation; which will be useful for laying new  cable underground safely in future.  

    more..
  • Voltage Miniature Relay

    Voltage Miniature Relay

    Get Price Quote

    • Power Consumption: 200 mW
    • Manufacturer: Panasonic
    • Manufacturer Part Number: DS4E-S-DC24V
    • Coil Type: Latching
    • Part Status: Active
    • Voltage Rating: 24 Vdc
    • Mounting Style: Through Hole
    • Product: Low Profile Relays
    • Current Rating: 2 Amp
    • Contact Form: 4PDT (4 Form C)
    • Packaging: Box
    • Product Category: Low Signal Relays - PCB
    • Series: DS Series
    • RoHS status: RoHS compliant
    • Termination Style: Solder Pin
    • Contact Material: Silver (Ag) with Gold Plating
    more..
  • 3.5VA Model Name/Number: Os-ex-2g /We77/Ex-eru(eru) Osna Smart Tanker Earthing Relay, Wall Mounted,

    3.5VA Model Name/Number: Os-ex-2g /We77/Ex-eru(eru) Osna Smart Tanker Earthing Relay, Wall Mounted,

    45,000 - 55,000 Per piece

    1 Piece (MOQ)

    • Country of Origin: India
    • Type: Wall Mounts
    • Brand Name: OSNA
    • Material: Aluminium
    • Diameter: 0-10mm
    • Thickness: 0-5mm
    • Certification: ISI Certified
    • Length: 10inch
    • Application: Tv Wall Mounting, Wall Mounting
    • Grade: ANSI
    • Color: Black
    • Feature: Accuracy
    • Surface Finishing: Polished
    • Structure: Horizontal
    • Usage: EARTHING RELAY
    • Name: OSNA TANKER EARTHING RELAY
    • Product: TANKER EARTHING RELAY
    more..
  • Earth Fault Relay

    Earth Fault Relay

    Get Price Quote

    Prok devices pvt ltd an iso 9001-2008 company introduces digital microprocessor micro controller based idmt definite time instantaneous earth fault relay (efr). It is a current sensing device which is semitropical professionally designed and tested for protection of generators, transformers and feeders. Prok dv's make digital microprocessor micro controller based idmt definite time instantaneous earth fault relay (efr) can be employed with various earth fault protective schemes

    more..
  • Earth Leakage Relay

    Earth Leakage Relay

    Get Price Quote

    • Model Number: IELR
    • Accuracy Class: 0.5/1.0
    more..
  • Cable Fault Locator

    Cable Fault Locator

    Get Price Quote

    We are offering cable fault locator we have great pleasure to inform to you, we provide complete set of equipments in the field of cable laying projects. Along with the same, as we discussed, we also deal in fault detection for u/g & o/h lines with pre warning facilities on the live line before the actual fault occurs & various testing equipments for electrical parameters on hv transformers, cables, ct, pt, gis, etc. Van mounted with all in one set of equipments.

    more..
  • 8KV Cable Fault Locator

    8KV Cable Fault Locator

    Get Price Quote

    1 Piece (MOQ)

    • Country of Origin: India
    • Operating Temperature: 0o C to 55o C
    • Power Supply: 230V AC, +/10 %, 50 Hz , Single Phase
    • Output Voltage: 08 Kv Dc Continuously Variable
    • Output Energy: 500/1000 Joules
    • Impulse Operation: Auto & Manual
    • Impulse Sequence in Auto Mode: 4 Sec , 6 Sec
    • Indication: ON/OFF indication
    • Storage Temperature: 0o C to 60o C
    • Weight: 60 kg Approx
    more..
  • STATOR EARTH FAULT PROTECTION FOR GENERATORS BY 20HZ INJECTION METHOD

    STATOR EARTH FAULT PROTECTION FOR GENERATORS BY 20HZ INJECTION METHOD

    Get Price Quote

    1 piece (MOQ)

    • Brand Name: SANDS
    • Country of Origin: INDIA

    In order to implement a 100 % stator earth fault protection based on sub harmonic injection, a 20Hz voltage is injected into the generator star point. The 20-Hz generator SGEN-1001 is used in combination with the band pass filter SBPF-1001 in the Stator Earth fault protection. Injection can be performed by connecting the SGEN-1001 and the SBPF-1001 to the load resistor of an earthing or neutral transformer. If an earth fault occurs in the generator star point, the 20 Hz voltage drives a current through the fault resistance. From the driving voltage and the fault current, the protective relay determines the fault resistance.

    more..
  • Overcurrent & Earth Fault Protection IDMT Relay,

    Overcurrent & Earth Fault Protection IDMT Relay,

    Get Price Quote

    1 Pack (MOQ)

    • Packaging Type: Carton Box, Wooden Box, Metal Sheet Box
    • Overall Weight: 100gm, 200gm, 300gm
    • Usage: Factories, Power Plants, Shopping Malls, VCB
    • Specialities: Stable Performance, Shocked Proof, High Performance, Heat Resistance, Durable, Dipped In Epoxy Resin
    • Size (Inches): 4-6 Inches, 6-8 Inches, 8-10 Inches
    • Overall Dimension: 580x260x465mm
    • Witdh: 80-120mm
    • Relay Height: 40mm
    • Relay Length: 30mm
    • Brand Name: CG
    • Shape: Square
    • Condition: New
    • Phase: Single Phase
    • Warranty: 1 Year
    • Country of Origin: India
    • Current Type: AC
    • IP Rating: IP30-50
    • Corrosion Resistance: Yes
    • Number of Poles: 3 Pole
    • Terminals: 3 Terminal
    • Switching Voltage For Zero: 220V
    more..
  • Miniature Power Relay

    Miniature Power Relay

    Get Price Quote

    • Features: 5A switching capacity, Surge restiveness 10000v
    • Creepage distance: 6.5mm
    more..
  • Single Phase Protection Relay

    Single Phase Protection Relay

    Get Price Quote

    • Trip Time delay: 2-3 seconds.
    • Output contact rating: 5 Amps at 230 V AC.

    Protection of induction motors against single phasing or reverse phasing or unbalance supply is one of the major problems in electrical systems. For safe running of 3-phase motors, special protections that keep a continuous watch on supply conditions are very essentials. The major cause of maxium motors burn-out is overloading which occurs due to unbalance supply or single phasing. Phase failure occurs in case of fuse blown-off, loose connections or loss of phase from supply itself.

    more..
  • Definite Time Earth Leakage Relay

    Definite Time Earth Leakage Relay

    100 - 19,219 Per

    1 Piece (MOQ)

    • Current rating ( In ):0.03 to 0.1A /0.3 to 1.0A: 110V/220V AC
    • 0.03 to 0.1A / 0.15 to 0.50A: 0.03 to 0.1A in steps of 0.01A
    • Cream & Dark Blue: 0.3 to 1.0Ain steps of 0.1A

    Features Bar graph indication of leakage current Remote reset and test facility Wide range of settings Low burden Principle of Operation: JRC 974 provides earth leakage protection for power systems. The relay operating time is determined by a programmable definite time delay. The relay measures the earth leakage current from the CBCT and if it exceeds the set threshold, it extends a trip signal after the operating time. The relay output contacts are self reset type. TEST button facilitates verification of relay contacts.

    more..
  • Earth Fault Relay

    Earth Fault Relay

    1,799 Per Piece

    • Number of Poles: 3 Pole
    • Current (Amps): 630 A
    • Model Number: MC61A-nX
    • Application: Electric Timer
    • Voltage Type: AC
    • Voltage (V): 220 v
    more..
    Pari Electricals
    Delhi
    0.0 View Profile
Filter by City
top