Hall Effect Experimental Setup
Get Price Quote
The set-up consists of following units : Hall Probe (Ge Crystal - n type), Hall Probe (Ge Crystal - p type) Hall Probe Multipurpose Stand, Hall Effect Set-Up, Electromagnet, Model EMU-50V Constant Current Power Supply, DPS-50 Digital Gaussmeter, Complete in all respect
dependence hall coefficient temperature apparatus
Get Price Quote
1 Set(s) (MOQ)
We offer Dependence of Hall Coefficient on Temperature usefull in physics and material science lab. The Hall voltage for p-carriers has opposite sign from that for n-carriers. Therefore if a semiconductor with p-type doping is gradually heated up, more and more electrons from its valence band will go to conduction band. As a result hall voltage would fall rapidly with temperature and even become zero or change sign. At the point of zero Hall Coefficient, it is possible to determine the ratio of mobilities b=µe/µh. The Hall coefficient inversion is a characteristic of only p-type semiconductors. The set-up consists of the following: 1. Hall Probe (Ge: p-type), HPP-22 Ge single crystal with four spring type pressure contacts is mounted on a glass-epoxy strip. Leads are provided for connections with the current source and Hall voltage measuring devices. Oven It is a small oven which could be easily mounted over the crystal or removed if required. Temperature Sensor Cromel-Alumel thermocouple with its junction at a distance of 1mm from the crystal. 2. Hall Effect Set-up :DHE-22 The set-up, DHE-22 consists of two sub set-ups, each consisting of further two units. Measurement of Probe Current & Hall Voltage This unit consists of digital millivoltmeter and constant current power supply. The Hall voltage and probe current can be read on the same digital panel meter through a selector switch. (a) Digital Millivoltmeter Specifications Range: 0-200mV (100µV min.) Accuracy: ±0.1% of reading ±1 digit Impedance: 1MΩ (b) Constant Current Power Supply Specifications Current: 0-20mA (10µA min) Accuracy: ±0.2% of the reading or ±1 digit Load regulated: 0.05% for 0 to full load Line regulation: 0.05% for 10% variation Measurement of Thermo emf and Heater current The unit consists of a digital millivoltmeter and constant current power supply. The thermo emf of thermocouple and heater current can be read on the same DPM through a selector switch. (a) Digital Millivoltmeter Specifications : Range: 0-20mV Resolution: 10µV equivalent to 0.25°C in terms of thermo emf Accuracy: ±0.1% of reading ±1 digit (b) Constant Current Power Supply Specifications Current: 0-1A Accuracy: ±0.2% of the reading ±1 digit Line regulation: 0.1% for 10% variation Load regulated: 0.1% for 0 to full load 5. Electromagnet, EMU-50V 6. Constant Current Power Supply, DPS-50 7. Digital Gaussmeter, DGM-202/ DGM-102 The experiment is complete in all respect.
Best Deals from Hall Effect Setup
Hall Effect Setup - Physics Lab Apparatus
Get Price Quote
1 Piece(s) (MOQ)
Hall Effect Experimental Setup
Get Price Quote
Hall Effect Experimental Setup, provide by us, is the best for finding number of carriers present or distinguishing between the carrier that is not possible through resistivity measurements of semiconductors. Hall Effect Experimental Setup that we provide has advanced tools for determining destiny of carrier and their mobility in conjunction with resistivity measurement. Clients can get Hall Effect Experimental Setup from us at competitive rates. Specifications : Hall Effect Set-up Model DHE -21 along with Ge Crystal either p or n type as per Cat. No. 1951.Electromagnet, EMU-50 as per Cat. No. 1944Constant Current Digital Power Supply, DPS-50 as per Cat. No. 1945Digital Gaussmeter, DGM-102 as per Cat. No. 1941
Hall Effect Setup
45,000 Per Piece
1 Piece (MOQ)
dependence 0f hall coefficients temperature
Get Price Quote
We Offer Dependence of Hall Coefficient On Temperature Usefull for Physics and Material Science Lab. the Hall Voltage for P-carriers Has Opposite Sign from that for N-carriers. Therefore if a Semiconductor with P-type Doping is Gradually Heated Up, More and More Electrons from Its Valence Band Will Go to Conduction Band. as a Result Hall Voltage Would Fall Rapidly with Temperature and Even Become Zero or Change Sign. At the Point of Zero Hall Coefficient, It is Possible to Determine the Ratio of Mobilities B=micro(e)/ Micro(h). the Hall Coefficient Inversion is a Characteristic of Only P-type Semiconductors. the Set-up Consists of the Following: 1. Hall Probe (ge: P-type), Hpp-22 ge Single Crystal with Four Spring Type Pressure Contacts is Mounted On a Glass-epoxy Strip. Leads are Provided for Connections with the Current Source and Hall Voltage Measuring Devices. oven it is a Small Oven Which Could Be Easily Mounted Over the Crystal or Removed if Required. temperature Sensor cromel-alumel Thermocouple with Its Junction At a Distance of 1mm from the Crystal. 2. Hall Effect Set-up :dhe-22 the Set-up, Dhe-22 Consists of Two Sub Set-ups, Each Consisting of Further Two Units. measurement of Probe Current & Hall Voltage this Unit Consists of Digital Millivoltmeter and Constant Current Power Supply. the Hall Voltage and Probe Current Can Be Read On the Same Digital Panel Meter Through a Selector Switch. (a) Digital Millivoltmeter Specifications Range: 0-200mv (100µv Min.) Accuracy: +-0.1% of Reading +-1 Digit Impedance: 1m Ohm (b) Constant Current Power Supply Specifications Current: 0-20ma (10 Micro Ampere Min) Accuracy: +-0.2% of the Reading or +-1 Digit Load Regulated: 0.05% for 0 to Full Load Line Regulation: 0.05% for 10% Variation measurement of Thermo Emf and Heater Current the Unit Consists of a Digital Millivoltmeter and Constant Current Power Supply. the Thermo Emf of Thermocouple and Heater Current Can Be Read On the Same Dpm Through a Selector Switch. (a) Digital Millivoltmeter Specifications : Range: 0-20mv Resolution: 10 Micro Volt Equivalent to 0.25c in Terms of Thermo Emf Accuracy: +-0.1% of Reading ±1 Digit (b) Constant Current Power Supply Specifications Current: 0-1a Accuracy: +-0.2% of the Reading +-1 Digit Line Regulation: 0.1% for 10% Variation Load Regulated: 0.1% for 0 to Full Load 5. Electromagnet, Emu-50v 6. Constant Current Power Supply, Dps-50 7. Digital Gaussmeter, Dgm-202/ Dgm-102 the Experiment is Complete in all Respect.
Hall Effect Setup
28,500 Per Piece
Hall Effect Setup
50,000 - 60,000 Per Piece
Hall Effect Setup, educational models, Blood collection mixer
Hall Effect Setup
Get Price Quote
Hall Effect Setup, Ultrasonic Interferometer, Four Point Probe
Hall Effect Setup
Get Price Quote
Hall Effect Setup, Understanding Digital Logic Circuits
Hall Effect Experimental Setup
Get Price Quote
Hall Effect Experimental Setup, Two Stage Reciprocating Air Compressor
Hall Effect Setup
Get Price Quote
Hall Effect Setup, joules calorimeter, Student Abacus