Heat pipe apparatus
60,000 Per piece
The unit consists of 3 identical cylindrical conductors in respect of geometry. One end of these is heated electrically while there are small capacity tanks acting as heat sinks at the other end. The unit consists of a heat pipe, a copper pipe & stainless steel pipe.Thermocouples are embedded along the lengths to measure the temperature distribution & the heat transfer rate is noted in terms of the temperature rise in the heat sink tanks
Heat pipe apparatus
35,000 Per Units
Best Deals from Heat Pipe Apparatus
Heat Transfer Lagged Pipe
Get Price Quote
FEATURES: 1. Study of the connected of double & single lagging 2. Study of effects of different insulating material combinations3. Electrical input control & measurement with complete penalized instruments.4. Digital Temperature indicator. INTRODUCITON:Lagging of pipes is required to prevent leakages of heat. The Apparatus is designed to study the lagging phenomenon. In Lagged Pipe Apparatus three concentric pipes are arranged between the pipes are filled compactly by two different insulating materials and heater is provided at the center of inner pipe. Temperature at various points is measured with Temperature indicator. Heat input is measured by Voltmeter - Ammeter. The assembly is mounted o angle frame. SPECIFICATION: 1) Pipesi) M.S. Pipe inside - 5cm dia. Approx ii) M.S. Pipe Middle - 10 cm dia approx.iii) M.S. Pipe Outer - 15cm 2) Length of Pipes -1m approx.Control Panel consisting of a) Voltmeter - 0 - 100/200 volts.b) Ammeter - 0 - 2 Amp.c) Diammerstat for heater, 0-230 V, 2 Amps.d) Digital Temperature indicator, 0-300 0 C with 10 C least count, using chromel-almel thermocouples, provided with cold junction compensation.4) Nichrome cartridge heater of suitable capacity and length EXPERIMENTATION: 1) To determine heat flow rate through lagged pipe and compare it with the heater input for known values of thermal conductivity of lagging material.2) To determine thermal conductivity of lagging material by assuming input to be heat flow rate 3) To plot temperature distribution across lagging material. SERVICE REQUIRED : 1) To determine heat flow rate through lagged pipe and compare it with the heater input for known values of thermal conductivity of lagging material.2) To determine thermal conductivity of lagging material by assuming input to be heat flow rate 3) To plot temperature distribution across lagging material. Almost care is taken for preparing this literature, but still if there are any mistakes, those may be excused. We reserve our right to change or modify the equipment without notice.
Heat pipe apparatus
Get Price Quote
Product Code: EKE 2302Heat pipe is an interesting device, which is used to transfer heat from one location to another. The apparatus consists of three pipes, viz. A heat pipe, copper pipe and stainless steel pipe. Ail the pipes have same physical dimensions. Copper and stainless steel pipes serve the purpose of comparison of heat pipe performance. All pipes are mounted vertically with a band heater at lower end and water filled heat sink at upper end. Nearly isothermal operation of heat pipe is clearly visualized from longitudinal temperature distribution of the pipe.Specifications: Heat pipe - Stainless Steel pipe, 25 mm O.D., 450 mm. Long. Sealed at both ends, evacuated and filled partially with distilled water - one No. Copper and stainless steel pipe of same size as that of heat pipe - one each. Equal capacity heater at bottom end of each pipe. Water filled heat sinks at upper end of each pipe. Measurements and controls Dimmerstat to control heat input to all the heaters - 4 amp. Capacity One No. A voltmeter and an ammeter to measure input to heaters One each. Multichannel digital temperature indictor to measure temperatures along the length of pipes.Four thermocouples are provided on each pipe. v Thermometers to note down water temperatures in heat sinks - 3 Nos. Services Required : 230 VA.C. Single Phase supply. Floor Area = 1 m X 0.5m X 0.5 m height.
Heat pipe apparatus
45,000 Per Units
1 Units (MOQ)
Heat pipe apparatus
35,000 Per Units
Heat pipe apparatus
Get Price Quote
Heat pipe apparatus
Get Price Quote
Heat pipe apparatus, wall mounted heater, heating panels
Heat Pipe Demonstrator Apparatus
Get Price Quote
Heat Pipe Demonstrator Apparatus, Orsat Gas Analysis Apparatus
Heat pipe apparatus
Get Price Quote
Heat pipe apparatus, Rope Brake Dynamometer, Critical Heat Flux Apparatus
Heat pipe apparatus
Get Price Quote
Heat pipe apparatus, Portable Petrol Engine, pedestal drilling machine