Integral Flow Orifice Assembly
9,400 Per Piece
1 Piece (MOQ)
Integral Meter Run Assembly
Get Price Quote
We are offering integral meter run assembly. An integral orifice assembly or integral meter run assembly is a specially designed prefabricated meter run used when a high accuracy in flow measurement is required for extremely small flow rates. It is also used when differential pressure transmitter is to be directly mounted on the assembly. This eliminates the cost of installation of differential transmitter with impulse piping to the orifice assembly. It is used for line sizes 2ã¢ï¿½ï¿½ and below.
Best Deals from Integral Orifice Assemblies
Integral Orifice Meter Run Assembly
81,900 Per Piece
1 Piece(s) (MOQ)
Integral Flow Orifice Assembly
Get Price Quote
We are Gujarat based Integral Flow Orifice Assembly Manufacturer, Supplier and Exporter. High-grade standardized raw material is used for manufacturing the Integral Flow Orifice Assembly. Our Integral Flow Orifice Assembly is available in diverse dimensions. The Integral Flow Orifice Assembly, we offer, has dimensional accuracy and can be installed cost-effectively. High reliability and low maintenance cost define our range of Integral Flow Orifice Assembly. Technical Specifications : Sealing Gasket : TeflonOrifice Plate : 316 SS ConcentricConnection : Flat ‘O’ Ring gasket surface, bolted to transmitter or 3 Valve manifoldFace-to-Face : 1/2â€Â³ and 1â€Â³ NPT – 3 11/16â€Â³ [93.7mm]Material : 316 SS, 304 SS as per AISI StandardPipe Size : 1/2â€Â³, 1â€Â³, 1 1/2â€Â³ N.B.Dimension : 1 1/2â€Â³ NPT, 4 1/16â€Â³ [103.2 mm] Ideal fluid types : liquid, gas, and steamAccuracy : up to ±0. 5% of volumetric flow rate Threaded Type : Accuracy : Uncalibrated Orifice Bore : +- 1.5% to +-5% of ratePressure Rating : 1/2â€Â³ and 1â€Â³ NPT, 300 psig at 300F, 1 1/2â€Â³ NPT, 1500 psig at 300F Construction : Integral Flow Orifice Assembly uses a Differential Pressure Transmitter, which has to be directly mounted on the orifice assembly. The Differential Pressure Transmitter has an impulse piping that is connected to the orifice assembly. The differential pressure transmitter is attached to the orifice assembly, with the aid of a 3/5 Valve H-type manifold. Integral Flow Orifice Assembly comprises an orifice plate, which is attached between two integral blocks that have a corner tap. The meter-run pipe, which the Integral Flow Orifice Assembly uses, should have upstream length of 750mm & a downstream length of 250 mm. These pipes need to be welded to the integral blocks with end flange. Since the transmitter cannot take high temperature, the Integral Flow Orifice Assembly works in a process temperature that is above 120 degrees centigrade. Availability : line sizes of 2â€Â³ & below Advantages Of Using Integral Meter Run Assembly : The use of an integral orifice flow meter eliminates the three measurement inaccuracies, which are recorded in the small-sized orifice line installationsThe honed body of the integral orifice flow meter considerably decreases ID uncertaintyDirect mounting of the DP transmitter is possibleThe velocity profile distortion of the pipe is reduced due to the insertion of precision bored downstream and upstream sections of pipeThe plate misalignment is reduced, owing to the self-centered design of Integral Orifice PlatesDecrease start-up time due to high flexibility of innumerable process connectionsHigh reduction (approx.. 50 %) in leak pointsComplete elimination of impulse linesMinimization of line plugging is done by removing long lines, crevices and small-bore ports, due to the direct mount designReliable installations
integral orifice plate assembly
Get Price Quote
Integral Orifice Assemblies
21,000 Per Piece
1 Piece(s) (MOQ)
Meter Run Assemblies
Get Price Quote
General Instruments Manufactured Integral Orifice Assemblies are another type of measuring flow device, which caters to the principle of maintaining constant reynolds number through out the process of media entering and processed and finally out of the assembly. This is possible with the precision manufactured device wherein the input flange, with pipe chamber, the orifice assembly and the outlet pipe chamber and the subsequent flange for the flange end connection, all shall be attributed to constant reynolds number.
Integral Flow Orifice Assembly
Get Price Quote
Integral Flow Orifice Assembly, orifice flange assemblies
Integral Flow Orifice Assembly
Get Price Quote
Integral Flow Orifice Assembly
Integral Orifice Assembly
Get Price Quote
Integral Orifice Assembly
Integral Orifice Assemblies
Get Price Quote
Integral Orifice Assemblies, Sight Flow Indicator, Sight Glass Indicator
integral orifice
Get Price Quote
integral orifice, annubar type sensor, condensing pots, Flow Nozzle
Integral Orifice Plate Assemblies
Get Price Quote
Integral Orifice Plate Assemblies, Level Indicator, Air Headers
Integral Meter Run Assembly
Get Price Quote
Integral Meter Run Assembly, Averaging Pitot Tubes
Integral Orifice Assemblies
Get Price Quote
Integral Orifice Assemblies, Insulation Compounding
Integral Orifice Assemblies
Get Price Quote
Integral Orifice Assemblies, Meter Run
Integral Orifice Plate Flange Assembly
Get Price Quote
Integral Orifice Plate Flange Assembly
Integral Orifice Plant Assembly
Get Price Quote
Integral Orifice Plant Assembly
integral orifice plate assembly
Get Price Quote
integral orifice plate assembly, Full View Flow Indicator
integral orifice plate assembly
Get Price Quote
integral orifice plate assembly, butt welding elbows, condensing pot