Humidity Test Chamber
Get Price Quote
Laboratory Environmental Test Chambers are designed & fabricated to suit various I.S. Standards application in the growing field of Medical, Agricultural, Industrial, Research Laboratories, Metal Treatment & Various Industries. We are the prominent Humidity Test Chamber Manufacturer, Supplier and Exporter of Humidity Test Chamber from Mumbai, India. Humidity Test Chamber, offered by us, has a cutting-edge technology to challenge & maintain climatic conditions above freezing what so ever & where ever you need. Features : Temperature + 10oC. To 60 oC Humidity (R.H.) 40% R.H. To 95% R.H. LCD display electronic temperature, humidity controller cum data logger with an accuracy of +/-0.50C & +/-3% R.H. PT � 100 sensors for dry & wet bulb / Capacitor type for humidity. Safety controller for prevent over shoot. Hermetically guard compressor and castor wheels for easy move ability. ISI mark kettle heater steam injection system and low water level alarm. Full Size through acrylic8 mm thick door. 1/12 Hp, 1440 RPM Motorized blower for circulation. Optional : Imported Sensor 0 to 100% R.H. , accuracy of = 2 oC Computer interface RS 485 / RS 232 interface for multiple single communication port Optional Accessories : Strip Chart Recorder. 0 to 24 hrs. Timer and regulating illumination conditions Note : Guarantee ceased in case of non-use of suitable servo stabilizer & to be stored in A.C. Room. Due to continuous R & D model/specification may change.
Neubauer Counting Chamber
2,600 - 3,500 Per Piece
2 Piece (MOQ)
Marienfeld Superior counting chambers are precise measuring instruments to determine the number of particles in liquids. made of special optical glass in compliance with DIN 12847 individually tested according to the German Calibration Ordinance planarity and tolerances are strictly observed tolerance of depth of chamber max. 2 % our counting chambers for investigations of cell suspensions are equipped with 2 sets of grids. In-vitro diagnostic (IVD) applications generally require duplicate determinations. Double counting grids = double check possibility. a cover glass with a thickness of 0.4 mm is placed on top of both external stages of the counting chamber to limit the volume over the counting grids. Thinner coverslips cannot be used as they bend because of the capillary forces. with 2 haemacytometer cover glasses 20 x 26 mm which are suitable for most counting chambers. For spare cover glasses please see here. counting chambers Fuchs-Rosenthal require cover glasses 24 x 24 mm and counting chambers Nageotte require cover glasses 30 x 30 mm. individually packed in transparent plastic box, 10 pieces in a carton counting grids are structured into two ground and polished surfaces on the central stage (= chamber bottom). This central stage is located between two elevated also ground and polished stages. Dark line:Under the microscope the lines of the standard counting chambers appear dark. Bright line:Counting chambers with bright lines have counting grids which are structured into a very thin, transparent metal coating. The bright lines contrast well with the dark metallic background and this facilitates evaluating cell suspensions.
Best Deals from Laboratory Chamber
Bacteriological Incubator
Get Price Quote
Salt Spray Test Apparatus
650,000 Per Piece
Environmental Test Chamber
Get Price Quote
Salt Spray Testing Chamber
Get Price Quote
1 Piece (MOQ)
Anechoic Chamber
2,500 - 4,000 Per Square Feet
These chambers are constructed with noise attenuating outer structures of modular panels and have all interior surfaces lined with PU wedges Foam.This has working floors constructed with grating floor sections to support heavy test specimens above the floor wedges.This is basically designed to suppress the internal sound reflections and used for acoustical measurements.
Walking Chamber
Get Price Quote
1 Unit (MOQ)
Sun Lab make Walking Chamber is designed for testing the capability of heat-endurance, cold-endurance, dryness-endurance, and humidity-endurance. Designed to Quality Control and R&D work across all industries. Temperature and Humidity conditioning of materials or products. Accelerated aging of samples and materials used to better understand product quality over extended periods. PLC Control system with touch screen display colored screen 4.3" HMI Displaywith Ethernet. Safety alarrn devices for Temperature and Hurnidity overshoot and undershoot. Standby Humidifier isavailable. Standby cooling systemsavailable. SS-316 water heaters provided for Humidity. Scanner single point Temperature and Humidity scanner with its complete sensor with transmitter will be provided. S.S Boiler Tank with its accessories will be provided. Cooling system make EMERSON with complete cooling accessories. Trays perforated stainless steel (SS 304) trays will be provided.
Mushroom Growing Chambers
Get Price Quote
1 Piece (MOQ)
Conditioning Chamber
Get Price Quote
Details : The equipment is provided with Digital Temp. & RH % Indicator Controller. A separate water tank with 1.5KW heater is provided to generate steam for humidity inside the chamber & temperature inside the chamber is obtained through heater along the 3 side walls of the chamber. For cooling ‘Emerson’ CFC free compressor has been provided” Heating is through Tublar finned air Heater and Cooling through CFC Free compressor. water tank with heater for steam generation. There is a air circulating fan also for uniform temperature.
Anechoic Chamber
3,000 - 10,000 Per Square Feet
Environment Walking Chamber
250,000 Per Piece
1 Piece (MOQ)
Bacteriological Incubator
Get Price Quote
1 Piece (MOQ)
Stability Chamber
Get Price Quote
1 Piece(s) (MOQ)
ConstructionDouble wall inner tank and outer body is dynamically designed. The Equipment interior is constructed with stainless steel 304 grade finish-4 and exterior is constructed with powder coated GI sheet/ stainless steel 304 grade finish-4.Optional Backup SystemEquipment is installed with PLC based auto change over backup system for Refrigeration system and Steam Generator system.PLC based control system Controlling system- PLC PC Communication via Ethernet PLC Based Safety cut off Rotronic make 4 to 20 mA sensors 4.3” HMI with TFT LCD Colour touch screen PLC based auto tune facility User based Alphanumeric password protection through HMI
Bacteriological Incubator
Get Price Quote
Double walled Chamber Inner constructed out of Stainless Steel and outer Mild Steel Powder coated/ epoxy painted in beautiful colors. 2.5o thick glass wool insulation, temperature controlled by Microprocessor based digital temperature controller cum indicator with suitable PT100 Sensor. Working temperature +5o above ambient to 80oC with an accuracy of ±1oC. Air ventilation provided on two sides. With option of dynamically balanced air circulation fan to maintain even heat within the chamber. The control panel has Power On /Off switch with indicator lamp for heating and Rotary selector switch. The equipment works on single phase power 240V AC 50 Hz. The equipment is supplied with adjustable wire mesh trays as standard and Perforated SS trays as optional.Optional : Safety blind Controller Air Circulating Fan Stainless Steel Perforated Trays Digital Timer Chamber Validation/ calibration Imported Microprocessor based PID Controller Digital Microprocessor based controller with RS-232 & PC inter phase Any other sizes can be supplied on demand Higher temperature accuracy models can be supplied on demand Fully Stainless steel model available on demand.
Pre Cooling Chamber
Get Price Quote
1 Piece (MOQ)
Humidity Stability Chamber
85,000 Per Piece
1 Piece (MOQ)
Walk in Bacteriological Incubator
Get Price Quote
1 Piece (MOQ)
When your testing requires a walk in rooms choose “TEMPO” controlled temperatures solution. Our test rooms feature automated process control, energy efficiency and a vast range of other features and options. Every “TEMPO” environmental room features equipment that reliably produces required conditions, structural integrity that keeps the room working properly through years of demanding test cycles, and measuring/monitoring equipment that precisely records all test data.Standard ModelsInside S.S. 304 with mirror polish & outside mild steel powder coated.GMP ModelsInside S.S. 316 with mirror polish & outside stainless steel 304 with the dull buff finish.ConstructionDouble walled constructed PUF modular panels ensure easy assembly at site. The leak proof door with a full gasket and airtight mechanical lock ensures there is no leakage through the chamber. The observation window (30 × 30 cm) is provided for viewing the sample inside the chamber. The unit is provided with perforated stainless steel trays.Technical Specification Air Circulation : The motorized blower at the backside of the chamber provides the recirculation of air which ensure the maximum uniformity of temperature and humidity inside the chamber should be maintained. Heating System : The high quality SS tubular heater made from the nichrome wire sheathed in SS tube is used. The special arrangement of heaters avoids the direct rendition of stored samples. Humidity System : High-quality U shape S.S. tubular heater is used for better heating. Humidity System : Steam injection system with water level arrangement is provided. A low pressure boiler tank and reservoir tank with duly argon welded is fitted with a float valve. When the water level in the tank is low the switch cut off. The ISI marked heating elements are used with the inbuilt stand by humidity system with auto change over the facility. Refrigeration System : The CFC Free hermetically sealed Emerson Copeland make compressor is used for better cooling with eco friendly refrigerant. The cooling system is made up of split type and the compressor is coupled with the condenser unit in a well ventilated area to avoid the hot air throw inside the chamber. Control System : The microprocessor based PLC (logging capacity of 1000 readings) with HMI touch screen 4.3″ colour display, which gives the direct display, the process value and the set value of temperature and humidity inside the chamber. The sensor (transmitter type 4-20 ma) which will accurately measure the temperature and humidity is provided with a high speed ethernet communication. The internal working area is illuminated. FeaturesThe sturdy design and long lasting finish ensure the minimum maintenance is required. The tongue and the grooves are moulded to close tolerance ensuring there is a tight fit between the panels. These prevent the condensation from forming on the foam a which minimizes the heat transfer. The high quality hardware like hinges and handles used in panels are indigenous and are imported.Safety Features Audio visual alarms are used for temperature and humidity variations. If the temperature increases above the 60°C the system will automatically cut off the dry heater, wet heater and the compressor. The float switch is used to cut off the wet heater supply in case of the water level in the tank goes below. Optional Features CFR 21 part 11 compliance software for PLC with RS 485 or ethernet communication Data logger CFR 21 part 11 compliance software for data logger Data scanner complete with sensor SMS mobile alert system Door access security system
Humidity Chamber Moveable (10 To 90% RH) (5 To 50 DegC Temp.)
175,000 - 210,000 Per piece
1 piece (MOQ)
Plant Growth Chamber
85,000 Per Box
1 Box (MOQ)
The Fitotron® SGC 120 Plant Growth Chamber offers unsurpassed accuracy and reliability in the control of temperature, humidity and lighting. Larger plants of up to 1.5m can be grown inside the SGC 120. The SGC 120 allows the researcher access to most world climatic conditions whilst eliminating the variability found in nature. Growth area up to 3.4m2 Available with up to 5 shelves Shelves can easily be added or removed by the user Individually controllable shelf lighting Max. growth height 1185mm Optional humidity up to 80%rh