Safeload Controller
Get Price Quote
LOADCELL CONTROLLER WITH 4-RELAY
3,600 Per Piece
01 Piece (MOQ)
LOADCELL CONTROLLER WITH 4-RELAY– 6+6 Dual Display Input: 0-30mVDC from Loadcell Auxiliary Supply - 85 – 270VAC, 50Hz or 24VDC (Factory Set) Output – 4 - Relay for switching Alarm Model No. - LDC-9664 Size (HxWxD) mm - 96 X 96 X 42
Best Deals from Load Controllers
Crane Safety Overload Limiter
185,000 Per piece
1 Set (MOQ)
The Crane Boy is a crane safety overload limiter integrating independent set points and built in display . Each of them activate a relay , specially conceived , dedicated and configured to hoists and crane load applications. Main Functions 3 – point overload alarm Automatic and manual calibration Parameter setup through menu Programmable digital filtering Self – inspection.
crane load controller
Get Price Quote
We are engaged in Manufacturing and Supplying Crane Load Controller, which is ideally used for overhead material handling and weighing applications. Crane Load Controller is engineered with precision to serve the needs of different industries. This Crane Load Controller is well known for compact design and high performance. Advantages : Rugged construction Simple to use Long life Compact design Applications : Tank weighing systems Check weighers Packaging /bagging /filling machines Crane weighing systems Technical Details : Full Software Calibration Available in various housings Various input options such as mV, mA, DC Voltage, ohms, etc. Various output options such as RS232, RS485 (MODbus), 4-20 mA, 0-5/10 VDC, Set Points with relay contacts, Parallel Printer, etc. In built facility of Audio-Visual Alarm with Acknowledge switch and Overload Trip relay contacts
LOAD CONTROLLER WITH INFLATION SETTING IM1507
Get Price Quote
Load indicators are weighing indicators controllers suitable for material dispensing applications. For discharging of material, usually pump or solenoid valve or a gate etc is used. On operation of the dispensing device, due to inertia as well as mechanical delays in switching off; additional material is discharged over and above the set value. Inflation setting is for correction of this error in discharging. User can set the value of extra material being discharged which will be subtracted from the set point and the discharging device is switched off prior to set point is reached avoiding the extra material discharge. eg. if set point is 10 kg and inflation setting is 250 gm, then relay will operate at 9.75 kg giving allowance for the extra material to be discharged. These controllers find applications in material discharge, batching and weighing applications, dispensing controllers etc.
Honeywell Load Cell Controller
Get Price Quote
Variable Load Controller
Get Price Quote
Be it any place or time; we make on time deliveries of the goods to the customers. We, along with our veteran packaging professionals, ensure that the packaging products commence keeping the packaging guidelines in consideration. We strictly use quality packaging material to evade loss during transit. Features : Complete system goes to safe mode during Malfunction of any IAQ sensors Ozone output regulation as per the VOC signal level In case of power failure the system retains the last set values Controller gives Audio / Visual alarm and cuts off ozone generation during High Ozone concentration Robust and reliable Low maintenance Easy to install
LOAD CELL CONTROLLER
3,000 Per piece
load cell contriller for tension control application, industrial machinery application
PID Auto Tune Controller with Heater Load Indicator.
28 Per Piece
10 Piece(s) (MOQ)
Model : pid-4cc pid-73 size : 48*48*90 mm 72*72*65 mm ip supply : 230vac,+-15%,50hz. ( others on request) ip sensor : a) j,k, tc (field selectable) b) ct for heater load.(50amp max) display indication : 3-raw of 3-digit (0.29") 7-segment red + green led display for pv,sv & load current. range : a) j-tc= 600'c b) k-tc=950'c c) 0.5 to 50.0 amp for heater load. indication accuracy: 0.25% of fsr or 1'c max,software calibrated lineariser. control accuracy : +-1'c of set value. resolution : a) 1'c for temperature b) 0.1 amp for load current. cjc automatic cold junction compensation for tc. setting method:: by front key pad control op:a) 1 co-relay op (5a@230vac) or isolated ssr op (+12vdc) for heater. b) 1 co-relay op (5a@230vac) for blower.
load controllers
11,700 - 18,000 Per piece
Digital Load Controller
Get Price Quote
Specifications: features: field programmability long term stored programmer retention external batch cycle actuation can be programmed for 3 step gate control functions for full, medium and dribble flows ideal for packaging machines.
Load Manager Controllers
Get Price Quote
Salient features suitable for 3p, 4w lt application. three line lcd backlit display to display voltage, current, active power, reactive power, apparent power, power factor, frequency and trivector energy. three push buttons on the front panel for programming and scrolling. available with rs485 modbus communication. 6 months history data of active energy, apparent energy & reactive lag & lead energy on rs485 communication which gets updated at 00.00 hours on the last day of the month. 6 months history data of kw md & kva md with date & time on rs485 communication which gets updated at 00.00 hours on the last day of the month. available in class accuracy 1.0 & 0.5
pc based electrical load control
Get Price Quote
At Kaushik ConInfra, we provide both mobile and stationary concrete batching plants to suit varied needs. We also offer customized equipment for high-scale construction projects. If you have any particular size and capacity specifications, you can consult with our experts for the best decision.
LOAD CONTROLLER WITH INFLATION SETTING
Get Price Quote
Load indicators are weighing indicators controllers suitable for material dispensing applications. For discharging of material, usually pump or solenoid valve or a gate etc is used. On operation of the dispensing device, due to inertia as well as mechanical delays in switching off; additional material is discharged over and above the set value. Inflation setting is for correction of this error in discharging. User can set the value of extra material being discharged which will be subtracted from the set point and the discharging device is switched off prior to set point is reached avoiding the extra material discharge. eg. if set point is 10 kg and inflation setting is 250 gm, then relay will operate at 9.75 kg giving allowance for the extra material to be discharged.
load controllers
Get Price Quote
Load Management Systems (LMS) are used to switch two LT circuits of Distribution Transformers of 11 KV feeders alternatively or as per predetermined schedule which controls the load fed by two circuits depending on the system requirement. LMS consist of Programmable Logic Control (PLC), MCCB, MCB, Bus bars, Contractors, CT's, Energy Meters, Modems, etc to provide all the load control functions and enable 24 hours supply to all consumers as per the requirement. PLC shall also facilitate timely Audit of the Transformer by communicating and acquiring all the necessary data from the Energy Meters.
SWASTIK LCC-961 LOAD CELL CONTROLLER LCC961
100 Per Piece
1 Piece(s) (MOQ)
swastik lcc-961 load cell controller lcc961 model: lcc-961 type: load cell controller voltage: 230 vac range: 0-50000 selectable condition: used & working qty: 1 pc available ref: am mk87 .
Variable Load Controllers
Get Price Quote
electronic load controller
Get Price Quote
We are offering electronic load controller.
load controller
Get Price Quote
Load Sharing Controller
Get Price Quote