Low Tension Current Transformer
600 - 1,800 Per Piece
10 Piece (MOQ)
Low tension current transformers mountable transformers used in Ring main units.
Dry Type Single Phase Low Tension Current Transformer
Get Price Quote
1 Piece (MOQ)
Best Deals from Low Tension Current Transformers
Low Tension Current Transformers
Get Price Quote
Low Tension Current Transformers
Get Price Quote
We are offering low tension current tape wound current transformer.
COMBINED LT CT 400/5A
Get Price Quote
05 Piece (MOQ)
Enriched by our vast industrial experience in this business, we are involved in offering an enormous quality range of LT Current Transformer 400/5A.
Low Tension Current Transformers
Get Price Quote
It transforms the high value current in primary circuit to low value current (1a / 5a) in secondary circuit in respective proportion. These are manufactured in tape wound, poylamide encapsulated and resin cast. We manufacture these for lt and ht application. We make available Low Tension Current Transformers in all standard ranges for different current rating, va Burden, different class of accuracy and different class of protection. We also manufacture cbct, differential ct, i ct, etc. We can manufacture cts as per customer demand.
Resin Cast Ring Type CT
Get Price Quote
10 Piece (MOQ)
LT Current Transformer
Get Price Quote
Based in Madhya Pradesh, we are a renowned LT Current Transformer Manufacturer and Supplier. LT Current Transformer is custom designed in 6.6kv, 3.3kv and 660v power capacities. Every transformer is stringently tested by the adroit engineers on various parameters to ensure efficient performance. We are efficient in catering to the bulk requirements of LT Current Transformer with utmost ease. Moreover, our LT Current Transformer is economically priced. Types of low tension current transformer : Tape insulated ring type c.ts with & without mounting arrangement. Tape insulated wound primary c.ts. Core balance c.ts. : used in detecting earth faults of very small Magnitude. A three phase cable is passed through these c.ts & the unbalanced current in the three phases set up a differential Flux giving rise to a current on the secondary side of these c.ts. They are sufficient to actuate a relay. Interposing c.ts. : used in matching the ratios of main feeder c.ts. for differential protection schemes. These also find application as saturable c.ts. used in conjunction with main feeder c.ts. They protect the meters connected to them by limiting the current flowing through the meters.
Low Tension Current Transformers
Get Price Quote
Ring CT- 30 1A or 5A, to 3500A 1A or 5A, Rectangle CT - 1001 or 5A to 63001 or 5A WPL - up to 1505A Accuracy Class 0.1, 0.2, 0.5, 1.0, 3.0 Protection Class 5P10, 5P20, 10P10, 10P20, PS
L T Current Transformer Resin Cast Ring Type
Get Price Quote
We are offering l t current transformer resin cast ring type. resin cast ring type ltct of various ratios type tested at nabl lab.
Low Tension Standard Current Transformer
Get Price Quote
Ours is a well-recognized firm based in Vadodara(India) and appreciated for offering qualitative products and that too at the best market prices. We keep a stern check on the payment procedures that we sternly follow and apart from this, we make a completely secured database that lists all the payments made and clients' details. Rest assured us for the payments, as we use leading technologies for the same.
Low Tension Current Transformer
Get Price Quote
We are offering Low Tension Current Transformer. The company is engaged in the provision of high quality Low Tension Current Transformer. The range of low voltage current transformer is up to 1.1kv, indoor & outdoor (dry type). It is available in bar and ring type in epoxy resin cast and tape wound.
LT Current Transformer
Get Price Quote
LT Current Transformer is used for converting primary current in to small standard current values which are ideal for the devices to which it is to be connected. The Low Tension Current Transformer made available by us is accessible in robust construction and is very endurable as well. Additionally, we are one of the eminent Lt Current Distribution Transformer Exporters from India. Low Tension Current Transformer Basic Functions of CTs are : To reduce line current to a value which is suitable for measuring instruments, relays etc.To isolate the measuring instruments, meters, relays etc. from line voltage of an installation.To protect measuring instruments against short circuit currents.To sense abnormalities in current and give current signals to protective relays to isolate the defective system. Current Transformers are Classified As RING TYPE CTs : A CT which has an opening in the center to accommodate a primary conductor (busbar or cable) through it.BAR -PRIMARY CTs A CT in which the primary winding consists of bar of suitable size and, material forming an integral part of the CT.WOUND TYPE CTs : A CT having a primary wi d-ing of more than ane full turn wound on the core.Tape Wound, Resin Cast, Abs/ Polycarbonate Enclouser.Product Range upto 30VAA ccuracy Calss .25,.5,1calssPrimary Amp upto 2000a.Built Primary upto 40amp.Our Current Transformer Manufacture with High Quality Core and Supply with Computerised Test Report Specification Requier for Ordering CTR. Primary currentSecondary currentVA BurdenAccuracy classInstrument security factorAccuracy limit factorEnvironmental condition Application Fault current of the systemVoltage of the systemAny special features requiredCTs manufacture by us confirme to ISS 2705, BS 3938, and IEC 185-186 standards.
Low Tension Current Transformer
Get Price Quote
We are offering low tension current transformers l.t.c.t. Resin cast & tape wound upto 0.66 k.v.
LT Current Transformer
12,000 Per Piece
1 Piece(s) (MOQ)
Amrest manufactures resin cast ring type and bar primary type LT current Transformer also manufacture of tape wound ring type LT CT. The standard value of the secondary current in CT is 1A or 5A. The Rated burden is genially used up to 15VA, (5VA, 10VA, 15VA) Accuracy of class in LT CT is, 0.5, 1.0 or 3.
Low Tension Current Transformers
Get Price Quote
low tension current transformers’ has been serving electrical industry & providing termination solution for the last five decades & Now serve larger segment of this industry, we are adding instruments transformers, both current & voltage Transformers to our range of product.
Low Tension Current Transformers
Get Price Quote
Low Tension Current Transformers are used for measurement andor protective applications in 660V Class. In Measuring Current Transformers (Refer TABLE- 1) main concern is the accuracy of the secondary current over a wide operating range. Typically the errors are guaranteed to be within specified limits. The nature of errors are current (Ratio) error and phase displacement. Metering current transformers are specified by (1) a burden and (2) accuracy class. Protective Current transformers (Refer TABLE-II) are specified by (1) a burden (2) accuracy class and (3) accuracy limiting factor. In other words the errors of the protective current transformers at the rated full loaded current as well as at a current given by the accuracy limit factor times the full load current are specified. There exists a class of protective current transformers for special purpose application known as class PS CTs. These are mainly intended for use in applications where the required characteristics of the current transformers cannot be conveniently expressed in terms used for class 5P, 10P and 15P current transformers. The knee point voltage, exciting current and secondary winding resistance are so dependent on the protective gear involved. The manufacturers of protection gear stipulates the requirements in terms of minimum knee point voltage and maximum exciting current. The current transformers of class PS type are of low reactance type since the core is made up of jointless ring type (spirally wound toroidal type) cores and secondary turns are substantially evenly distributed along the whole length of the magnetic circuit.
Lt Current Transformers
Get Price Quote
We are known as the prominent Manufacturer, Exporter and Supplier of the LT Current Transformers. A wide range of LT Current Transformers is available with us, which is widely used in the diverse industries. Similarly, our range of LT Current Transformers includes Rectangular Type Current Transformer, Resin Cast Current Transformer, Ring Type Current Transformer, WPL Type Current Transformer and ABS Case Current Transformer.
Low Tension Current Transformers
Get Price Quote
Current transformers convert an alternating current usually high in to a proportional lower one, depending on their use. Measurement type CTs are required to transform the primary current, at various classes of accuracy, as specified by the class designation, over a current range from 1 to 120 percent of its rated primary ratio. The design of this type of transformer requires the inclusion of a core and winding which will when connected to its rated burden; perform within the limits of error as indicated by the standard’s specification. It is an advantage for a measurement type transformer to saturate above this range, which provides a protection against damage to instruments by limiting the secondary current when surge currents or faults appear in the primary circuit.
Lt Current Transformers
Get Price Quote
'EMMESS' manufactures a wide range of LT current Transformers to suit Industrial dimensional standards and specific customer requirement. They include LT tape insulated Current Transformer ( Varnished Cotton Tape/Fibre glass tape & PVC Tape ) with/ without fixing dimensions. LT Resincast Current Transformer (Ring Type/Rectangular Type, wound primary type) Hylam Mounted Wound primary Current Transformer. Lab grade Precision current transformers Bushing/ Bus duct current Transformers Summation current Transformer Core balance current transformers