osmometer
450,000 Per Piece
1 Piece(s) (MOQ)
KNAUER Germany GmbH make freezing point Osmometer Model K-7400S (5 Years warranty) incl. measuring head for plastic sample tubes (A0840-2)Power cableRS-232 connection cable500 Pack of sample tubes(A0272)400 mOsmol/kg calibration solution (A01241-1)850 mOsmol/kg calibration solution (A01250)Pack of lint-free cleaning tissue (A02330)
osmometer
425,000 - 525,000 Per Unit
01 Piece (MOQ)
Use ful for Osmomolality measurement of all aq solution . Application in Pharma formulation Eye Drops OVD Nasal Drops, Nasal sprays. SVP , Inectables. . Clinical Samples Serum Urine Osmomolality.
Best Deals from Osmometer
Freezing Point Osmometer
650,000 Per Piece
1 Units (MOQ)
osmometer
600,000 - 1,800,000 Per Piece
01 Piece (MOQ)
freezing point osmometer
osmometer
500,000 - 600,000 Per Piece
Digital Osmometer
Get Price Quote
Freezing Point Osmometer
650,000 Per Set(s)
1 Piece(s) (MOQ)
Osmometer The offered array of products is examined on the basis of quality of raw material and other inputs used for the manufacturing. Rest assured us for the raw material used, as we have most updated technologies to examine the quality. We stringently follow the safety packaging guidelines, thus we are flexible enough in delivering the products to the clients. We only use the finest packaging material to evade loss during transit. Other Details: OSMO 210 Osmometer requires only a 30µL sample size, which provides accurate osmolality results in less than 90 seconds For convenience, the fully accessible probe design is easy to clean and service The OSMO210 is not only your most reliable option, it's the easiest to use. Just pipet 20µL of sample into a disposable sample tube, then place the tube into the test chamber Lower the probe into the sample and push the "Test" button Results are displayed in ninety seconds Clinical Applications of Osmometry: Determine Osmol Gap : actual vs calculated osmolality is a rapid indicator for toxicology and trauma cases Remember, only freezing point method is sensitive to alcohol and ketones Mannitol Treatment : maintain, without exceeding, critical level of therapeutic infusion Glycine Ingestion : monitor the absorption of irrigation fluids in surgical procedures Differentiate DKA and NKH : only a measured osmolality can make this determination and guide effective therapy Renal Function : evaluate concentrating ability and monitor ADH therapy Hydration Status for Athletes : weight class and endurance events are conducive to dehydration, with performance and health consequences Sample Authentication for Drug Screens : low urine osmolality is indicative of tampering
osmometers
Get Price Quote
It is an instrument designed to test the osmolality according to the measurement of the freezing point depression of the solution in injections, eye drops, blood, urine etc.
Vapor Pressure Osmometer
Get Price Quote
The Model 833 Vapor Pressure Osmometer is an effective, easy to use tool for the determination of number average molecular weights of any non-volatile solute in the range of 100-25,000 Dalton. Principles of Operation The vapor pressure osmometer operates on the principle of differential vapor pressure between a pure solvent and a solution. Two carefully matched thermistors are placed in a chamber saturated with solvent vapor. When solvent is placed on both thermistors, they assume the same temperature. If a solution is placed on one of the thermistors, condensation heats the thermistor until the vapor pressure is raised to that of the pure solvent. The change in temperature causes a resistance change in the thermistor. This change in resistance is measured by a sensitive bridge circuit and displayed on a panel meter, strip chart recorder and/or computer terminal. A calibration curve relates the change in resistance to the molal concentration of the solution The Model 833 VPO incorporates many improvements over other designs to simplify and improve molecular weight determinations. The cell and thermistor geometry are designed to minimize dilution of the sample by solvent condensation. This results in much slower “fall-off” and allows a much longer time window for readings. The syringes on the Model 833 are mechanically driven to insure more precise fluid delivery and are independently heated to minimize any equilibrium upset when introducing sample. This results in a faster equilibration time (typically 2-5 minutes), better reproducibility and greatly reduced cycle time per sample.
Semi-Micro Osmometer
Get Price Quote
The Semi-Micro Osmometer K-7400 measures the freezing point depression of liquids and it is based on the succesful predecessor model Type Dig. L The principle of total osmolality is to determine the osmolality of body fluids such as blood (serum) and urine.
osmometers
Get Price Quote
osmometers, Medical Equipments, X Ray Machine, Ionization Detectors
Freezing Point Osmometer
Get Price Quote
Freezing Point Osmometer, deuterium lamp
Single Sample Osmometer
Get Price Quote
Single Sample Osmometer, Hi-psi Patient Detectors, Radiation Field Detectors
osmometer
Get Price Quote
osmometer
Vapour Pressure Osmometer
Get Price Quote
Vapour Pressure Osmometer, Li 200sa Pyranometer Sensor
osmometers
Get Price Quote
osmometers, Automated Slide Staining Machine
osmometers
Get Price Quote
osmometers, Microscopes