Digital Photo Fluorometer
18,999 Per unit
1 unit (MOQ)
Digital Flame Photometer
50,400 Per Piece
1 Piece (MOQ)
Best Deals from Photo Meters
Microprocessor Based Flame Photometer
16,400 Per Piece
1 Piece (MOQ)
FLAME PHOTOMETERS
65,500 Per Piece
1 Piece (MOQ)
Microcontroller Flame Photometer
50,000 Per Piece
1 Piece (MOQ)
Qubit 4 Starter Digital Photo Fluorometer with WiFi
Get Price Quote
Sample Volume 1 to 20 µL Includes Fluorometer, Assay Tubes, Wi-Fi Dongle, Assay Kit Excitation Wavelength 470 nm (Blue LED), 635 nm (Red LED) For Use With (Equipment) Qubit Fluorometer Product Line Qubit™ Type Qubit 4 RNA IQ Starter Kit, with WiFi For Use With (Application) sdDNA Quantification, RNA Quantification, Protein Quantification Unit Size 1 kit
SI-206 Digital Duel Display Flame Photometer
Get Price Quote
Microprocessor Based Flamephoto Meter
42,000 Per Piece
1 Piece (MOQ)
Digital Actophotometer
6,500 Per Piece
1 Piece (MOQ)
Activity Cage Actophotometer
Get Price Quote
1 Piece (MOQ)
681 Digital Fluorometer
Get Price Quote
1 Piece (MOQ)
Digital Photo Fluorometer Model 681 is designed for precise analysis of fluorophors such as vitamins, quinine, steroids, fluorescein, metal complexes, etc. The Fluorescence is caused by the absorption of radiant energy and the re-emission of some of its energy in the form of light. In fluorescence, the excited molecule returns to the ground state immediately after excitation, when the fluorescent molecule is excited at the fixed wavelength (primary filter). The amount of light emitted is measured at the particular wavelength (secondary filter). Fluorometer method for the determination of fluorophors is more sensitive than the Colorimetric method. The Primary Filters – Corning 5840 & Corning 5113 and secondary filters – Corning 4308, Corning 3486 and Corning 3385 mounted on holders are supplied with the instrument The fluorescence is collected at 90 degree angle to minimize the interference of excitation source to fall on the sample solution only during a measurement. Features 3 Digit LED display Covers entire visible range Determines the concentration of Flurophors & Quinine
Flame Photometer
29,000 Per Piece
1 Piece (MOQ)
Digital Aerosol Photometer
Get Price Quote
We are latest and easily to used computerized photometer access now a day, our products are standards and the unique materials for filtrations system honesty testing. Providing the fully useful for the base unit, unlimited personally activity in this field. Aerosol photometer access with fixed example for using in different situation. Printer Three unique report functions are now available with the 2i through the USB or optional thermal printer interface. Continuous mode offers the same output as ATI’s legacy photometers to ensure backward compatibility. Monitoring mode provides the ability to collect data at user defined intervals for long term sampling. Summary mode, which gives discrete reporting capability for individual filter locations, can output to the thermal printer to meet customer documentation requirements. iProbe The iProbe goes about as an expansion of the based instruments through an almost indistinguishable UI. Choice symbols from the based units are present. This catch, the testing area chosen and exchanged by method for an electronics control valuing systems.
Microprocessor Flame Photometer
45,000 - 120,000 Per piece
1 Piece(s) (MOQ)
Microprocessor Based with Printer Interface Auto Flame Failure Detection, Sample Data Storage Facility Four Measurements in Single Aspiration, Setup Storage Facility Curve Calibration Programmability Using Maximum of 5 Standards, Multiple Calibration Curve Saving Facility Data Processing Through Curve Fitting Techniques, Least Square, Quadratic, Direct Results in ppm and meq, Useful for Medical & Soil Testing Product description The sample solution is aspirated through an automiser. Sample, Air and the fuel are mixed in the mixing chamber which is then sprayed as a very fine mist into the flame. The color of the flame is changed depending upon the concentration of elements present. Radiations from the flame passes through the sensing system and specific narrow band interference filter which permits only the characteristic radiation to pass to the photo-detector. The output of the photo-detector is then processed by the microcontroller and the final results are displayed on graphical lcd display. In both models 5-Point calibration facility and non-linearity correction is provided through an automatic curve fitting software. Microprocessor Based with Printer Interface Auto Gas Cutoff Auto Flame Failure Detection Four Measurements in Single Aspiration Setup Storage Facility Sample Data Storage Facility Curve Calibration Programmability Using Maximum of 5 Standards Multiple Calibration Curve Saving Facility Data Processing Through Curve Fitting Techniques, Least Square, Quadratic Online Help Key Direct Results in ppm and meq Useful for Medical & Soil Testing Mode: General, Serum, Urine Sensitivity: General: Na: 0.5 ppm, K: 0.5 ppm, Li: 0.5 ppm, Ca: 15 ppm Filters: Na & K supplied (Ca & Li are optional at extra cost) Resolution: 0.1 ppm/meq Reproducibility: < 1% coefficient of variation for 20 consecutive samples using 10 ppm Na set as max standard Curve Fit Accuracy: < 2% error when 3 ppm Na/K and 5 ppm Li are set as maximum standards Display: 128 x 64 Graphical LCD Display Flame System: LPG and dry oil free air Detector: Silicon photodiode Calibration: Upto 5-Point calibration with curve fitting software Flame Failure:Auto detection.
Microprocessor Flame Photometer
Get Price Quote
1 Piece (MOQ)
Digital Actophotometer
Get Price Quote
Bluefic Industrial And Scientific Technologies is a prominent digital actophotometer manufacturers in India. Our digital actophotometers are perfectly designed so that the client can study the spontaneous or induced or locomotor activity of small animals like mice and rats in the laboratories. The results start showing after about approximately 5 minutes after which the scores can be recorded. The apparatus is manufactured with emitters and optical sensors which are highly beneficial in recording the horizontal movement of the animals in question. The stimulus is variable in nature. The drugs that can be used to conduct the tests are barbiturates and alcohol which decrease the motor activity when required.
Flame Photometer Digital
46,200 Per Box
1 Box (MOQ)
Max Electronics India is an established manufacturer, supplier and exporter of sophisticated Flame Photometer from India. The Flame Photometers offered by the company are high on quality, performance and are made of the finest quality raw materials, making them durable and long lasting. Flame-photometers are used for determination of Sodium, Potassium, Lithium and Calcium in […] Digital Flame Photometer with 2 filters , Na & K Filters , Auto Ignition . 3 digit LED display along with compressor and other accessories No. of Filters Na & K ( Ca & Li optional ) Range Na: 0 to 100 ppm Ca: 20 to 100 ppm K: 0 to 100 ppm
Digital Photo Fluorometer
Get Price Quote
Digital Photo Fluorometer
Get Price Quote
1 Piece (MOQ)
Flame Photometer
32,000 - 45,500 Per Piece
1 Unit (MOQ)
FLAME PHOTOMETER DIGITAL with Na & K Filters Compressor included. Auto Ignition