LLC 2SR Water Pump Automation System
Get Price Quote
10 Piece (MOQ)
PRODUCT FEATURE : This model is suitable to single phase push button starter, fully automatic for both tank Suitable any single phase Motor up to 5 HP Dry run protection, Load capacity 40 A 2 relay, 240 VAC Auto and manual mode provided Sensor fault detection provided Sensing element : 6 no S.S sensor Electrolysis free design, ABS Body Warranty Service : Repair or Replacement. 1 Automation unit. 1 user manual with technical details Silent Feature : Suitable for single phase motor up to 5 HP. Also suitable for single phase MCB starter panel, submersible motor. Can connect with and without starter panel. Suitable for Single Phase any type of Push Button Starter Panel. Visual Indication for Power and Motor ON & OFF. Long service Life, Easy Installation, Sturdy Construction, Efficient operation. Working : When the water level of overhead tank becomes low means water get down from middle sensor and if water is present in the underground tank, motor get start automatically. The tank starts filling up. When the water level reaches to the higher level, the top level sensor sense. The motor automatically gets switched off. No Man Power required Protect motor from dry running. Auto off when tank is full or sum is empty. Auto / Manual / Bypass / Fuze Switch available. Application : Applicable to underground tank, overhead tank, pressure pump, tube well and deep boring. Automatic water level controller is of much used in like Useful at: Homes, Bungalows, Apartments, Commercial complexes, Hotels, School, Colleges, Hospitals, Residential Colonies and Industries etc. use of this product Saves Water,Saves Electricity, Saves Times and Saves Man Power. Helps in preventing overflow of water from the Overhead tank.
supply water pump automation system
4,000 - 4,500 Per
01 Long Ton (MOQ)
Best Deals from Pump Automation Systems
water pump automation system
5,000 - 10,000 Per Set
1 Set (MOQ)
Pump Automation System
Get Price Quote
Pump Automation System
Get Price Quote
Features Automation System is advance micro controller based and designed for TWIN PUMP installations and can operate both pumps in wide variety of modes. The user can use the system on single pump installations also and the second pump control can be used as a redundant or stand-by feature. The operation of the pump is done by switch ON and switch OFF time, which is stored as one sequence in Automation System̢۪S memory. The user can set 9 sequences in a single day such sequence into Automation System. Automation System also gives Time Compensation against power bad condition. Automation System also equipped with LEVEL based pump control system. The system automatically starts the pump when water level down to set level in the OHT and stops the pump when water level reaches to high level in the OHT (Over Head Tank) or low level in the UGT (Under Ground Tank). The system does not allow starting the motor when water level in the UGT is not sufficient and protect the motor from dry run. Automation System provides protection against reverse phasing and single phasing. Automation System provides time delay (from 1 min. to 10 min.) when power recovers or pump tripped or pump OFF event occurs. This will be provided to avoid nuisance tripping, protects pump and prevents pipeline from back water thrust. Automation System also equipped with pressure sensing technology. In certain cases when all the taps of the pipelines are not in use (approx. 60% of taps are closed), pressure in the pipeline will rise and that damages the pipeline joints or pipeline. To protect from this over pressure, Automation System is equipped with settable pressure gauge. When pressure rise up to the limit, system will automatically tripped the pump and prevents the pipeline. For maintenance point of view, Automation System will continuously calculate and totalize total no. of hours of pump ON operation.
pump automation systems
220 Per 0
Over flow alarm 220volt Transformer
water pump automation system
15,000 - 20,000 Per Piece
A water pump is used to transport water from one location to another. To suck water in so that it can be expelled, a pump must be able to rapidly alter pressure within a system. How a water pump achieves this pressure change is what allows certain pumps to be more beneficial to certain applications than others.
Pump House Automation System
Get Price Quote
1 Set (MOQ)
As the ideal fit for pump houses, pump stations & wastewater pump stations, Pump House Automation System can help to control water pumps for maintenance of water level within normal limits. It sends alarm messages immediately to Internet SCADA and to service men's GSM (Mobile) phones in the event of an abnormal condition. It is equipped with an energy meter which can easily calculate approximate power consumption and costs.  Remote Control Operation : User can send commands from the web browser or SCADA application to the remote pump house to switch on/off montors. Switching can also be done from the mobile phone. You get a response SMS for every action. Data Storage & Monitoring : The data is stored on server for analysis & report generation . Server is hosted (24/7/365). Customer doesn't need to investments on server PC and its maintenance tasks.Customer can see status of their remote targets, print monthly reports, analyze productivity, check maintenance.browse alarm views, trend views, process picture views, target control views, report views, trouble ticket views...  Features in SCADA : Fault diagnostics and reports Days min/max values Hourly averages Pump efficiency bargraph curve Pumps operating counts & times day, week, month, year diagrams. Power consumption day, week, month, year diagrams Flow rates day, week, month, year diagrams All information can be read to EXCEL for own reports etc.
Pump Automation System
Get Price Quote
For continuous measurement of liquid level and to control auto/manual pumpimg system Â
pump automation systems
Get Price Quote
SCADA & Telecom for Control & Monitoring of wide spread Assets E-house and Electrical Power distribution system Wellhead Automation, Instrumentation and Fieldbus solutions Variable Frequency Drives and Soft-starters High Integrity Pressure protection System ( HIPPS) Integrated control system comprising DCS , ESD and F&G Turbine control system
pump automation systems
Get Price Quote
Total command area is of 6978 hectares and it is divided into 57 zones of approximately 100 to 150 hectares and each zone is further divided into 16 sub-sections.After detailed designing Saisanket was able to optimize the cost of Distribution Network with the use of Air Management System, Outlet Management System, Electric Energy less and Wireless Automation etc and enable client to use these system for better efficiency, Project can operate as per the variable schedule depends on varying crop water requirement , rainfall, Maintenance, No Water Requirement.Remote Metering, Controlling, monitoring & synchronization of 912 nos Outlets Chaks (Discharge at every outlet is from 50 lps to 110 lps) with zonal pumping stations , intake & 2nd stage pumping station.
water pump automation system
Get Price Quote
Aqua-SCANET is the SCADA system designed specifically for real-time online monitoring and control of water distribution networks. All key water distribution parameters for public and industrial water distribution are monitored controlled. The system provides wireless monitoring of the Pumping Stations, Tubewells and associated flowproduction data and valve operations on control room PC and also provides real time alarmsdata on your mobile sets. Special control options of remote dial-in and auto dial-out enable the user to remotely access the status of critical plant parameters. Uninterrupted operation of control system is guaranteed by automatic transfer to battery mode in case of power failure. It also supports a variety of communication options including existing telephone network, RS 422485 wired network, VHFUHF Wireless radio network and Satellite global network.
pump automation systems
Get Price Quote
M-Commander is a micro-processor based Motor protection and Pump management system, suitable for 2 pumps, Sensing voltage, current and temperature, Protecting against Phase Failure, Unbalance, Phase sequence, Under/over voltage, Overloading, dry running, winding over temperature, Over current/Short circuit, Locked rotor, earth fault. Auto/Manual resetting, Adjustable trip settings for UV/OV, UC/OC, O/L, Locked rotor & earth fault, On delay & start-up delay adjustable, 2x1CO output relays RTC based time settings, Water level control. Motor protection Includes Under /Over voltage protection Single/Reverse phasing protection Voltage / Current unbalance Overload trip Over current protection Dry running protection Earth fault protection PTC based winding overheating protection
Pump Automation System
Get Price Quote
Pump Automation System, poly green house, Drip Irrigation System
water pump automation system
Get Price Quote
water pump automation system, Energy Saving Devices
water pump automation system
Get Price Quote
water pump automation system, Fisher Clamp, Wire, Led Light, Ceiling Fan
pump automation systems
Get Price Quote
pump automation systems, high voltage rectifiers, tacho generator
water pump automation system
Get Price Quote
water pump automation system, Light Management System, Energy Saving System
water pump automation system
Get Price Quote
water pump automation system, Control Panels, water pump automation system
water pump automation system
Get Price Quote
water pump automation system, Architectural Drafting, breaks, water supply