Secondary Injection Relay Test Kit Dealers

(9 products available)
  • CV-100 Secondary Injection Over Current Relay Test Kit

    CV-100 Secondary Injection Over Current Relay Test Kit

    Get Price Quote

    1 Piece (MOQ)

    • Brand Name: Sudharsan Insulation
    • Country of Origin: India
    • Material: MS
    • Frequency: 50
    • Model Number: SI / CV – 50 & SI / CV – 100
    • Input:: 220V, 50Hz, 1Ph
    • Applications: Secondary Injection Testing of Static-Over current/Earth fault relays/Electromagnet (CDG) relays

    Features Undistorted Sine wave Injection Current. Performance comparable to Alstom...s CFB Test kit. Simultaneous availability of AC Injection Current and auxiliary AC / DC outputs. Digital Panel meters for Volt / Amp / Timer. Suitable for both NO / NC trip contacts of Relays under test. Input overload protection with MCB for Current Injection and 0.5A glass fuse for Auxiliary AC/DC outputs. Powder coated ms enclosure, portable with lifting handles and front panel protection with a lockable hinged cover.   Dimensions 425x390x280mm, Wt 28Kg for CV- 50 560x450x300mm, Wt 42Kg for CV- 100   Specification Type SI / CV – 100 AC Injection Current - Isolated from mains (60 sec rating), continuously adjustable from 0.01 to 100A on 3VA burden relay. Auxiliary output - continuously rated, non isolated from mains 0 – 250V, 0.75 A AC 0–300V, 0.5A DC   Type SI / CV – 50 AC Injection Current - Isolated from mains ( 60 sec rating), continuously adjustable from 0.01 to 50A on 3VA burden relay. Auxiliary Output –continuously rated, non isolated from mains 0 – 250V, 0.75 A AC 0–300V, 0.5A DC

    more..
  • secondary injection kit

    secondary injection kit

    Get Price Quote

    1 Piece (MOQ)

    • Application: Clinical, Hospital
    • Feature: High Accuracy
    • Packaging Type: Box
    • Country of Origin: India
    • Power: 230 volts
    • Frequency: 50Hz
    more..
  • Best Deals from Secondary Injection Relay Test Kit

  • 20 Amp Relay Test Kit

    20 Amp Relay Test Kit

    Get Price Quote

    1 Piece (MOQ)

    • Country of Origin: India
    • Input: 230V AC, single phase, 50Hz
    • AC/ DC Volt Output: Con􀀧nuously variable 0 230VAC Capacity 150 VA (Max)
    • Time Measurement: 0 9.999 Sec to 9999 Sec in four ranges
    • Measuring CT: Mul􀀧 ra􀀧o wound primary current transformer
    • Variable Auto Transformer: The Current output will be cutoff incase of any overload or even if the relay under test actuated
    • Current Metering: Digital Meter Basic Range : 0 1A/ 5A AC Scaled in 0 to 100% for all selected range Accuracy : 1.5% o

    Features : Potential free start and stop signal Continuously adjustable outputs Portable Models Digital Ammeter, Voltmeter and time interval meter (Unitimer) UniTimer automatically puts OFF the output, when timer reaches to its maximum value of the selected range to ensure safety of the instruments as well as the item under test. Wide range of measurement, i.e. From 0. 001 second. To 9999 secs in four ranges

    more..
  • secondary injection kit

    secondary injection kit

    Get Price Quote

    • Model: MOT-RTS10,MOT-RTS20,MOT-RTS50,MOT-RTS100,MOT-RTS200
    • Timer range: 0.0001-9999Seconds Auto Ranging,Tripping with Potential Free contact
    • Duty Cycle: 30Min ON,10Min OFF
    • Operation: Manual
    • Display: LED
    • Indication: Bright LED for Power ON & Test ON
    • Mains Supply: 230 V AC,50Hz +/-10 Percent
    • Protection & Safety: Cutoff toggle switch Fast blow glass fuse
    • Current: 0-10A,0-20A,0-50A,0-100A,0-200A - Refer Model
    • Selectable Current Ranges: 0-1-5-10-25-50-100-200 Refer Model
    • VA Burden: 200VA,400VA,600VA
    • O/P AC / DC Voltage: 0-250V AC / DC
    • Voltage Accuracy: +/- 0.5 Percent of Reading
    more..
  • secondary injection kit

    secondary injection kit

    Get Price Quote

    • Feature: Digital meters for display of AC& DC voltage & AC current Digital time interval meter range from 0.0001sec to 9999sec

    The MOTWANE make secondary injection kit (MOT-SIK) has different models with range of output currents from 25A to 100A. HRC fuse protection is provided for over loads & control circuits. Bright LED indicators are provided for indicating input output status. The SIK comes with adequate air cooling systems. It is having one knob control to select the output current. Separate knob provided for coarse control. The SIK is generally called as Relay test set when used for testing of relays .This can be utilized for current injections during commissioning of protection Relay systems, testing of equipments like Ammeters, voltmeters , transducers, energy meters in power sub stations.25A with 3ph AC output with provision of DC output model is also available.

    more..
  • Secondary Injection Relay Testing Kit

    Secondary Injection Relay Testing Kit

    Get Price Quote

    • Voltage Generators: 4 x 0 to 150 V
    • Current Generators: 6 x 0 to150 A
    • Binary Inputs: 8
    • Phase Angle: -360 to +360
    • Frequency sine: DC, 10 Hz - 1000 Hz
    • Current Generators Power: 150 VA @ 15 A, L - N
    more..
  • Secondary Injection Relay Test Kit

    Secondary Injection Relay Test Kit

    19,500 Per Piece

    • Brand Name: AS Electrotech
    • Color: Black, Blue, Cream, Gray, Red
    • Feature: Active, Confortable, High Accuracy, Skin Friendly, Suitable For Self Testing, Tiny Blood Sample Required
    • Material: Mild Steel
    • Relay Current: 500 Amp
    • Weight: 16 Kg
    • Power Source: Electric
    • Surface Finish: Color Coated
    • Rated input power: AC 220V+-10% 1000VA 50Hz
    • Phase: 3 Phase
    more..
  • secondary injection kit

    Get Price Quote

    Dual Channel Transformer Winding Resistance Meter, high voltage relay

    more..
  • secondary injection kit

    Get Price Quote

    Transformer Winding Resistance Meter

    more..
    Motwane
    Sonebhadra
    0.0 View Profile
Filter by City