Single Phase Isolation Transformer
20,000 Per Piece
1 Piece (MOQ)
48VA Single Phase Isolation Transformer
Get Price Quote
10 Piece (MOQ)
Best Deals from Single Phase Isolation Transformer
Single Phase Isolation Transformer
18,000 - 25,000 Per Piece
1 Piece (MOQ)
Single Phase Isolation Transformers
10,000 Per Piece
1 Piece (MOQ)
Isolation Transformer 3KVA
7,000 - 10,000 Per Piece
1 piece (MOQ)
single phase isolation control transformers
1 Per Piece
1 Piece(s) (MOQ)
Single Phase Isolation Transformer
4,500 - 8,000 Per Piece
1 Box (MOQ)
Single Phase Isolation Transformer
Get Price Quote
When generators are installed, it is common to use four pole changeover switchgear or contactors when transferring from mains to generator, resulting in the traditional neutral-earth reference being lost during transition. This can cause the phase voltages to rise alarmingly and any sensitive single phase loads could be damaged. By adding a bypass isolation transformer it allows the electrical contractor to earth the UPS output neutral, thereby eliminating this problem. Single phase bypass transformers are also installed on small systems where the client requires the UPS output neutral to be earthed.
Single Phase Isolation Transformer
Get Price Quote
Riding on the unfathomable volumes of industrial expertise, we are engaged in offering Single Phase Isolation Transformer. Our business is based in Delhi, India. Owing to its hassle-free functioning, shock-resistance, faultless performance, and long working life, it is profusely demanded by our clients. We conduct rigorous testing of this product on various parameters, to ensure adherence to the global quality standards. We offer it at the leading market rates. Detail : We are proficient in manufacturing, exporting, retailing and supplying an outstanding array of Single Phase Isolation Transformers that is designed using high grade factor inputs and latest technology. These are widely used for removing power line noise, surges, spikes and transients. Useful in isolating the equipment from noisy power line; these can be availed in various customized options. The offered transformer is developed with high precision in order to meet the international quality standards. These are widely accepted by clients for their high accuracy, smooth operations, high insulation resistance, low maintenance and longer service life. In order to ensure their unmatched quality and flawlessness, these are thoroughly inspected on various parameters.
Single Phase Isolation Transformer
35,000 Per
Single Phase Isolation Transformer
Get Price Quote
Manufacturer & Supplier of Single Phase Isolation Transformer. Our product range also comprises of X-Ray Transformer and Three Phase Isolation Transformer. Single Phase Isolation Transformer Single Phase Isolation Transformer product of ours is a better option for our clients as these isolate the equipments from noisy power line. They eliminate the Power Line Noise, Surges, Spikes and Transients. It also provides high insulation resistance and provides complete Electromagnetic and Electrostatic Shielding. Our Transformers are Core Type Transformers ranging 500 VA on-wards with insulation class 'B' or 'F'.
Single Phase Isolation Transformer
Get Price Quote
Isolation Transformers, which often has symmetrical windings, is used to decouple two circuits. An isolation transformer allows an AC signal or power to be taken from one device and fed into another without electrically connecting the two circuits. Isolation transformers can be used to block transmission of DC signals from one circuit to the other, but allow AC signals to pass. They will also block interference caused by ground loops. Isolation transformers with electrostatic shields are used for power supplies for sensitive equipment such as computers or laboratory instruments.A 3 phase transformer, there is a three-legged iron core as shown below. Each leg has a respective primary and secondary winding. Thus a 3 phase isolation transformers is a 3 phase transformer which has isolated primary and secondary windings to allow the power input to be isolated from the power output.
Single Phase Isolation Transformer
5,000 Per Piece
Single Phase Isolation Transformer
Get Price Quote
We are manufacture & supplier wide range Single Phase Isolation Transformer. This type of transformer are used in homes, offices and factories to control the transfer of power. Our heavy electric transformer manufacturer using high quality of raw material. these transformers are applauded by our clients for efficient functionality, easy operation and robust build.
Single Phase Isolation Transformer
Get Price Quote
Single Phase Isolation Transformer is available in variegated technical specifications. We hold expertise in manufacturing, exporting and supplying quality transformer that are used on all systems that require grounding on the load. Our isolation transformer is a copper wound, multi-shielded, single phase, K-factor rated, high efficiency, power conditioning isolation transformer. It is duty rated and belongs 600 volt class. This isolation transformer supports harmonic rich non-linear loads while maintaining safe operating temperatures. Easy to install and maintain, this isolation transformer is reckoned for its high quality, efficiency and reliability. Standards : The power conditioning system is designed in accordance with applicable portions of the following standards: American National Standards Institute (ANSI C57.110 & C62.41-1991) Institute of Electrical and Electronic Engineers (IEEE 519-1992) National Fire Protection Association (NFPA) 70, National Electrical Code (NEC) Federal Information Processing Standards Publication 94 (FIPS Pub 94) UL Listed to Standard 1561 C-UL listed to CSA Standard C22.2, No. 47-M90 Input Specifications : Nominal AC input voltage ratings: 480 VAC, 240 VAC or 208 VAC, 1 phase, with sufficient margin to sustain a constant input of +10% without saturation. The nominal operating frequency: 60 hertz + 3 hertz. The power conditioning system’s primary is configured single phase, two wire, plus ground, and includes full capacity taps at 2½ % increments, two (2) above and four (4) below the nominal voltage tap. Energizing inrush current will not exceed 10 times the full load input current for ½ cycle. Performance Specifications : Load Regulation : Maintained within +2.5% or less of nominal, from no load to full load. Overload : 500% for 10 seconds, and 1,000% for one cycle. THD : ≤ 1% added to the output voltage waveform under a linear load. Output Voltage : Sinusoidal with no flat topping when high crest factor (3.0 : 1), non-linear loads are present at the output. Audible Noise Measured at 1 Meter from the Unit : ≤ 50dBA Electrostatic Shielding : Incorporates two, or an optional three, solid copper foil electrostatic shields which minimize inner winding capacitance, transients, and noise coupling between primary and secondary windings. Common Mode Noise Attenuation : 126 dB with two shields, or 146dB with optional three shields. Transverse Mode Noise Attenuation : 3 dB down at 10kHz, decaying 20 dB per decade. Optional TVSS : Incorporates a fused (with front panel mounted, blown fuse lamp indicator), secondary connected, 3 mode spike suppression network. The TVSS is comprised of high energy metal oxide varistors with less than a 5 nanosecond response time and a maximum peak current handling capability of 40,000 amps (8x20μsec) per mode. Thesuppression network system will remain functional when subjected to ANSI/IEEE C62.41 Category B-3 waveforms. The spike suppression network increases the transverse mode noise attenuation to 3 dB down at 10kHz, decaying 40 dB per decade. Main Transformer : Transformer Windings : All copper conductor construction, with separate primary and secondary, isolated windings. The transformer conforms to NEC article 250, that specifies a separately derived power source. The neutral conductor is sized for 200% of the ampacity of the phase conductor.Terminals are provided for isolated single phase output conductors, neutral conductor and ground. All leads, wires and terminals are labeled to correspond with the circuit wiring diagram. Basic Impulse level : No less than 10,000 Volts. MTBF : ≥ 200,000 hours. Transformer Steel : Grain oriented, M6 grade, silicon steel. Flux density : ≤ 15k gauss. Core losses : ≤ 0.6% of the KVA rating. Insulation : Class N, 200OC with a maximum temperature rise of 115OC above ambient, not exceeding 130OC under nonlinear loading per UL 1561. Cooling : Natural convection. Cabinet : Enclosure : NEMA type 1, floor mounted, and indoor enclosure. Construction : Cabinets are manufactured from 14 gauge steel with base sub-structure suitable for fork lifting. Paint : Baked on, powder coat paint finish with proper pre-treatment. Provisions exist to hardwire input and output power connections to terminals located within the unit enclosure. Input and output conduit landing locations are available on the rear of the unit enclosure. Environment : Operating Temperature Range : -20OC to +40OC. Humidity : 0 to 95% non-condensing. Altitude : Up to 5000 feet above sea level without de-rating. Warranty : Manufacturer guarantees equipment to be free from defects in material and workmanship for a period of 2 years following shipment from the factory
Single Phase Isolation Transformer
Get Price Quote
Isolation transformers offered by A3S are constructed with high insulating materials and special shielding techniques to attenuate common mode and minimising transverse mode noise.The use of high insulating materials and special shielding techniques results in an attenuating common mode and minimises transverse mode noise. The core and its magnetic properties are properly selected to provide sufficient leakage inductance. This will give the greatest attenuation of normal mode power line noise possible, consistent with the transfer of fundamental power frequency, while all higher frequencies are blocked. Designed with split winding constructions and bifilar connections to reduce overall capacitance of the winding Due to the better regulation, it does not generate common mode impedance coupling effect
Single Phase Isolation Transformer
Get Price Quote
1 Piece (MOQ)
Single Phase Isolation Transformer
Get Price Quote
An Isolation Transformer is 1:1 ratio transformer. It has a copper foil shielding in between primary and secondary winding.FEATURES:It protects the output load from spikessurges or any other noise which occurs in the main supply.The spikes being high voltage transient should not be allowed to enter the load as it may damage the precious equipments.
Single Phase Isolation Transformer
32,000 Per Piece
Single Phase Isolation Transformer
Get Price Quote
We offer single phase isolation transformer. Our esteemed clients can avail immaculate single phase isolation transformer. Manufactured by making use of high-grade basic material and components, these products conform to the defined parameters of the industry. These products are widely applied to the single phase power supply of import-export equipment, safe-isolation power supply, step up-step down power supply, rectifier equipment power supply, detecting system power supply and kinds of machinery power supply. Furthermore, to cater to the diversified demands of the clients, we offer these products in different specifications. some of the features of single phase isolation transformer are as follows: longer functional life robust construction easy to operate non-corrosive body