Automatic Smoke Curtain
Get Price Quote
1 Piece (MOQ)
Automatic smoke curtains work with fire curtains and SHEVS systems to protect against fire, smoke, and hot gases. These barriers save lives and property, enabling open-air designs where a permanent fire-rated partition would otherwise be required. Features For larger widths, multiple overlapped curtains are available with intelligent controls. The connected bottom bar ensures synchronized descent. Our system includes a gravity-based fail-safe mechanism that ensures the curtain will always descend to its operational position, even in a complete power failure. Segmented or facetted curtains can be achieved using a curved bottom bar if desired. Smoke sealing is available for the "S" class designation (UL 10D). Our motor system incorporates current sensing technology and offers additional options such as fire alarm override, voice warning, and monitoring systems. It is also cost-effective and trouble-free, with a two-stage descent facility and strobe light. The Smoke Curtain complies with several standards, including EN 12101-1:2006, BS 7346 Part 3, and UL 10 B, C, D. It also meets the requirements of BS EN12101-1, deflection standards of BS EN12101-1, BS 7346 Part 4 2000, and UL 10 B, C, D & DS, BS7346 Part 3 1990. Rigorous testing has been conducted on curtains that overlap and join together. This ensures reliability, adjustable, safe speeds, and edge gap gravity fail-safe measures.
Automatic Fire and Smoke Curtains
Get Price Quote
We stand as a distinguished Supplier of Automatic Fire and Smoke Curtains from Karnataka, India. We offer an assortment of Fire and Smoke Curtains that are lightweight and have quick response time. We are capable of handling bulk orders of Curtains and ensure clients receive their order on a timely basis. Clients can obtain Automatic Fire and Smoke Curtains from us at most affordable rates.
Best Deals from Smoke Curtains
smoke curtain
Get Price Quote
Smoke curtains are designed as barriers to contain and/or to channel away smoke, heat and superheated gases as a vital part of a SHEVS (smoke, heat, exhaust, ventilation system).IPEC Smoke Curtains are designed to activate upon receipt of a signal from either a fire alarm system, or locally positioned detector. Smoke Curtains are used to: 1. To act as a smoke separating element within the building design to prevent the passage of smoke, heat, superheated gases for a predetermined period of time in either the vertical or horizontal orientation.2. To assist designers to form smoke reservoirs and compartments to minimize lateral smoke spread and/or to assist the SHEVS (smoke heat exhaust ventilation) system.3. Can descend after a set predetermined period of time, to a predetermined position to assist with protected means of escape.4. Descending to a predetermined position for a predetermined time to create a smoke layer reservoir, ensuring the protected means of escape remains open longer prior to descending to their fire operational position after planned evacuation times.With ever increasing environmental safety legislation putting more restrictions on building design; integrating smoke containment systems that are compatible with good design is making designers lives easier. Smoke Curtains are proving to be the first choice for combining effective smoke protection with the latest trends in interior design.An effective smoke curtain should operate automatically in the event an alarm signal, a prolonged power failure, or equipment or wiring corruption. An automatic smoke barrier must always deploy in a safe and controlled manner.Solid barriers can provide effective smoke containment, but automatic Smoke Curtain are far more sympathetic to the requirements of design, appearance and building function.The design and installation of a smoke barrier system into a building should always be carried out by qualified consultants and engineers. Consideration must always be given to providing adequate means of escape and rescue.
smoke curtain
Get Price Quote
In many buildings smoke containment systems such as Smokemaster are used to prevent the movement of smoke and heat from one area to another. Smokemaster is rated to contain smoke at a temperature of up to 600 °C for 30, 60, 90 or 120 minutes, depending on which version is selected. SMOKEMASTER IS AVAILABLE IN THREE VERSIONS: Single units (type “SI”). Double vertical (type “DV”) units, where continuous runs with overlapped fabric to form a continuous barrier are required. Double horizontal (type “DH”) units, where there is a premium on space under the ceiling.
smoke curtain
Get Price Quote
Fire curtains and smoke curtains are very important to the safety of life and building, hence fitting the best is mandatory. Packman is very happy to provide guidance and assistance on specifying about fire and smoke curtains. Our service sectors include hospitals, shopping malls, airports, leisure complex, hotels etc. These curtains can withstand vast temperatures on one side yet keep the opposite side relatively cool. They do not get heated up for an hour in case of fire. Our fire and smoke curtain have market leading features and the highest technical specification available, yet offers a cost-effective and flexible solution to fire and smoke control.
Automatic Smoke Curtain
Get Price Quote
Automatic smoke curtain prevents the movement of smoke and heat from one area to another in a fire by channeling or containing the smoke and heat.
Fire And Smoke Curtains
Get Price Quote
Pacific markets a Gravity Fail Safe (GFS) Smoke and Fire Curtain, which has become the benchmark for most Smoke and Fire Curtain systems sold around the world today. Due to the high performance and reliability of these Fire products, they have been specified and installed in most of the world's landmark buildings. An automated fire barrier, which is normally hidden within the ceiling or wall structure, and only deployed in the event of a fire or for testing purposes. It is designed to prevent the spread of fire & smoke and super heated gases through a building. All vertical and horizontal fire and smoke curtains are BSI and LPCB Quality Assured. Both active and passive smoke ventilation products, together with intelligent controls can be integrated into a total SHEVS (Smoke, Heat, Exhaust, and Ventilation Systems) package. Benefits Invisible (recessed above the ceiling line) Creates open spaces and increases yield of living space, workable / chargeable floor space Creates clear lines of sight by removing compartments Increases the scope of internal design possibilities Creates solutions for radical property design and development Maintains building fire integrity without compromise Increase tenability levels of escaping occupants Lower long term service and maintenance costs compared with tradition passive fire protection solutions Removes the need for heavy fire doors Removes the need to fix around the perimeter of the void between support columns Design Solutions & Applications: Means of escape and protected routes Stairwells Atria Escalators Shop fronts Lift lobbies Boundary protection Alternative to traditional fire doors, shutters, glazing partitions and non-load bearing walls Clear opening through corridors, communal and reception areas Secondary means of fire separation Basement and loft conversion fire separation Kitchen dinner conversions Applicable For: High Rise Buildings Hospitals Refinery Metro Railway Stations Airports Power Plants Industrial Building Malls & Multiplexes Hotels Laboratories Thermal Power Station Audotoriums Software Parks Restaurants Universities Shopping / Retail Centres Car Parkings
smoke curtains
Get Price Quote
The fabric used for 1 hour fire rated curtains is generally used for smoke curtains. They can be either static or automatically controlled. The smoke curtains may not be installed with side guides as there is a tolerance allowed around the edges through which smoke may seep. The overlapping of one motorised curtain against another is used to cover larger expanses. The curtain is retained together with the overlapping and also that of a steel rod fed through the bottom pocket.
smoke curtains
Get Price Quote
Smoke Barriers will control the spread of smoke in a building and protect the means of escape and create tenable conditions. Active Smoke Barriers comprise technologically advanced fire-resistant fabric barriers encased in a compact steel housing. Barriers remain invisibly retracted until activated by an alarm or detector signal, at which time they descend safely to their fire operational position. To be compliant, Smoke Barriers must be protected from a short circuit and or total power failure, this is achieved with our patented Total Gravity Fail-Safe (TGFS) system.
Fire Smoke Curtain
18,000 Per Square Meter
smoke curtains
Get Price Quote
smoke curtains, Fire Curtains, Fire Protection Systems
smoke curtains
Get Price Quote
smoke curtains, automatic fire curtains, automatic smoke curtains
smoke curtain
Get Price Quote
smoke curtain, fire telephone system, video analytics
smoke curtains
Get Price Quote
smoke curtains, Curtain Rod, Curtain Tracks, Fire Curtains, Monsoon Blinds
Fire And Smoke Curtains
Get Price Quote
Fire And Smoke Curtains
smoke curtain
Get Price Quote
smoke curtain, jet fan
Smoke Fire Curtains
Get Price Quote
Smoke Fire Curtains, Weld Drapes, Smoke Releasing Windows
smoke curtain
Get Price Quote
smoke curtain, Cellulose Pad, Celdek Pad, Evaporative Cooling Pad
Smoke And Fire Curtains
Get Price Quote
Smoke And Fire Curtains
BLE Smoke and Fire Curtains
Get Price Quote
BLE Smoke and Fire Curtains, ridge ventilators, downspouts