Soil Analyzer Kit Dealers

(45 products available)
  • Water Analysis Kit, Soil Analysis Kit

    Water Analysis Kit, Soil Analysis Kit

    13,000 Per Piece

    1 Piece (MOQ)

    • Country of Origin: India
    • Packaging Type: Box
    • Usage/Application: For Water And Soil Testing
    • Type: Portable
    • Material: Plastic
    • Range: 0 - 14 pH
    • Model: 361R
    more..
  • 1160 Microprocessor Water & Soil Analysis Kit

    1160 Microprocessor Water & Soil Analysis Kit

    Get Price Quote

    1 Piece (MOQ)

    • Country of Origin: India
    • Condition: New

    Features pH, Conductivity, TDS, DO Salinity, mV & Temp. Measurements Turbidity Measurement (Model – 191) Both Turbidity & Colorimetric Measurement (Model – 172) Mains cum Battery Operated Available in ABS Plastic Briefcase

    more..
  • Best Deals from Soil Analyzer Kit

  • Digital Water & Soil Analysis Kit

    Digital Water & Soil Analysis Kit

    28,000 Per Piece

    1 Piece (MOQ)

    • Country of Origin: India
    • Automatic Grade: Manual
    • Warrenty: 1 Year
    • Brand Name: Pap-Tech
    • Resolution: 0.1 ppt
    • Accuracy: 0.5 ppm ± 1 Digits
    • Automation Grade: Manual
    • Usage/Application: Used to Accurately Analyze the Given Water & Soil Samples
    • Display Type: Digital
    • TDS Accuracy: ±0.5 % FS ± 1 Digit
    • DO Range: 0-20 ppm
    more..
  • SI-159 Water and Soil Analysis Kit

    SI-159 Water and Soil Analysis Kit

    Get Price Quote

    Salient Features 16x2 alpha numeric backlit LCD display Temperature and parameter display simultaneously Real time display in 24 hour format Simple menu driven controls using soft keys Storage upto 1000 samples 230 V + 10% 50 Hz with inbuilt 12V rechargeable battery Serial RS-232 and parallel centronics computer interface Print selection - datewise or all data Standard Accessories : pH Electrode, Buffer solutions (4.00, 7.00), Conductivity/TDS/Salinity Cell, DO Probe, DO Membrane Temperature Probe, ORP Electrode (at extra cost), Operation Manual, Data cableTurbidity is available in Model SI-159 with following additional specifications: Sample System: 30 mm clear glass test tube Light Source: 6V tungsten lamp Detector: Photodiode/photocell

    more..
  • Digital Water & Soil Analysis Kit

    Digital Water & Soil Analysis Kit

    Get Price Quote

    1 Piece (MOQ)

    • Type: Digital Water & Soil Analysis Kits
    • Certification: ISO 9001:2015 & CE Certified
    • Feature: Measures 8 parameters - pH, mV/ORP, Conductivity, Salinity, D.O., Temperature, TDS and Turbidity
    • Packaging Type: Fitted in a briefcase
    • Warranty: 1 Yr
    • Data Storage Memory: Data can be stored for 1000 Samples
    • Kit Weight: 6.5 Kg.
    • Power Supply: 230 V +/-10%, 50 Hz AC / 12 V Rechargeable Battery
    • Brand Name: VSI
    more..
  • Radicon Microprocessor Water and Soil Analysis Kit ( Model RC 28 )

    Radicon Microprocessor Water and Soil Analysis Kit ( Model RC 28 )

    Get Price Quote

    • Warranty: 1 Year
    • Product Name: Radicon -microprocessor Water & Soil Analysis Kit Model Rc – 28 . (7 Parameters)
    • Brand Name: Radicon
    • Model: RC-28
    • Display: 16 characters x 2 lines alpha Numeric BL LCD

    PH: Range & Resolution - pH 0 to 14.00 & pH 0.01. Accuracy & Temp. Comp. - pH 0.01 ± (relative) & Automatic with Pt 100 Sensor Calibration - Automatic & Manual   Dissolved Oxygen: Range & Resolution - 0 to 20 ppm & 0.1 ppm Accuracy & Temp. Comp . - ± 0.2 ppm ± 1digit & Automatic with Pt 100 Sensor. Calibration - Automatic & Manual   ORP: Range & Resolution - -2000 to ± 2000 mV & 1 mV Accuracy - ±0.1% ± 1digit.   Temperature Range & Resolution - -100 to ± 200 deg.C & 0.1 degree C Accuracy - ±0.2% ± 1digit Calibration - Automatic & Manual   Conductivity: Range & Resolution- 0-200.0 mS/cm & 0.01 uS/cm Accuracy & Temp. Comp.- ± 0.5% & Automatic with Pt 100 Sensor Cell Constant & Ref.Temp - 0.05 to 2.0 adjustable & 25 degree C   TDS: Range & Resolution - 0-200 ppt & 0.1 ppm Accuracy - ± 0.5% TDS factor 0.5 by default (adjustable)   Salinity: Range & Resolution - 0-50 ppt & 0.1 ppt Accuracy & Temp. Comp. - ± 0.5% & Automatic Salinity factor - 0.75 by default ( adjustable) Power supply - AC 220V/50 Hz

    more..
  • Digital Water & Soil Analysis Kit

    Digital Water & Soil Analysis Kit

    Get Price Quote

    We offer Digital Water & Soil Analysis Kit that is designed to deliver accurate results with utmost convenience. Superior quality material is used to manufacture our Digital Water & Soil Analysis Kit along with latest techniques in its designing and production. Due to this, easy operation, reliability, impeccable accuracy and precise engineering are the key attributes of our Digital Water & Soil Analysis Kit. SpecificationsType (Digital Water & Soil Analysis Kit)Ph Range0to14pHTemp. Comp.0oto100oC MaunalResolution0.01 pHAccuracy± 0.01 pH ± 1 digitConductivityRange0-20ms, 0-200mTemp. Comp.Pre AdjustableResolution0.1 Mi9cro MhosAccuracy± 0.5 %FS ± 1 digitT.D.S.Range0-20ppt, 0-200pptCell ConstantPre AdjustableResolution0.1 ppmAccuracy± 0.5 f=SD ± 1 digitORP/mvRangeOto ± 1999mVTemp, Comp.imVResolution± 1mV ± 1digitTemperatureRange0o-100o CAccuracy-+0.1oC ±1 digitResolution± 1mV ± l digitD.O.Range0-20 ppmAccuracy±0.3 ppm ± 1 digitResolution0.1 ppmTemp, Comp.5o-50oC (Manual)

    more..
  • Microprocessor Water and Soil Analysis Kit

    Microprocessor Water and Soil Analysis Kit

    Get Price Quote

    • Model: S- 967
    • Product Name: µP Water and Soil Analysis Kit
    • Display: 16X2 Line Alphanumeric Jumbo LCD
    • Range: 0-14 pH
    • Resolution: 0.01 pH
    • Accuracy: ± 0.01, ± 1 Digit
    • Temp. Comp.: 0-100°C, (Auto/ Manual)
    • Range: 0-20, 0-200 µS0-2, 0-20, 0-200 mS, 0-1000 mS
    • Resolution Selection: 0.01 µS
    • Accuracy: ± 0.5% FS, ± 1 Digit
    • Cell Constant: 0.05-10.5, Adjustable
    • Temp. Comp.: 5-50°C (Auto/Manual)
    • Reference Temp.: 5-50°C (Auto/Manual)
    • Range: 0-100°C
    • Resolution: 0.1°C
    • Accuracy: ± 0.1°C, ± 1 Digit
    • Sensor: PT-100 (RTD Probe)
    • Range: 0-20, 0-200 ppm,0-2, 0-20, 0-200 ppt, 0-1000 ppt
    • Range Selection: Automatic
    • Cell Constant: Adjustable
    • Resolution: 0.01 ppm
    • Range: 0-±1999.9 mV
    • Resolution: 0.1 mV
    • Accuracy: ±0.1 mV, ± 1 Digit
    • Range: 0-20, 0-200 ppm0-2, 0-20, 0-50 ppt
    • Resolution: 0.01 ppm
    • Accuracy: ± 1% of range, ± 1 Digit
    • Range: 20 ppm
    • Resolution: 0.1 ppm
    • DO Sensor: Gold/Silver Probe
    • Temp Comp.: Auto/Manual (50°C)
    • Accessories: pH Electrode, Cond/TDS/ Cell, Probe, DO Probe , DO Membranes, Tables 7pH & 4pH,12V Adapter, Software CD, RS 232 Cable, Operation Manual.
    • Features: Highly Accurate & Stable, User Friendly & Menu Driven Software .
    more..
  • Soil Analysis Kit

    Soil Analysis Kit

    Get Price Quote

    1 Piece(s) (MOQ)

    • pH, Conductivity, TDS, DO, Salinity, mV & Temperature Measurements: Highly Accurate & Stable
    • User Friendly & Menu Driven Software: 16 x 2 line Alphanumeric LCD with Backlit
    • Printer Attachment facility: Storage for 90 Samples

    We offer microprocessor water & soil analysis kit.for efficient use of nutrients in the soil, to test the purity of drinking water and for waste water testing, the company has introduced microprocessor water and soil analysis kit – 1160. This is a unique portable instrument for measurement of various parameters i.e. Ph, conductivity, tds, salinity, temperature, dissolved oxygen and mv of any solution. A chargeable sealed lead acid battery is provided within the kit that makes it extremely useful for field and laboratory use. the use of latest microcontroller technology makes it reliable, accurate and low power consuming instrument.

    more..
  • Digital Water & Soil Analysis Kit

    Digital Water & Soil Analysis Kit

    19,000 Per Piece

    • Brand Name: manti lab
    • Model Number: MT-131

    Digital Water & Soil Analysis Kit (Product Code: MT-131/132/133) We are the leading manufacturer and supplier of water & soil analysis kits. Which are used to accurately analyze the given water & soil samples. We have different variants of this product. These instruments are successfully serving the specific soil and water analysis requirements of the clients, and offer a cost effective solution to their needs. 1. Digital Water & Soil Analysis Kit 7 Parameter (MT-131)        2. Digital Water & Soil Analysis Kit 6 Parameter (MT-132)  3. Digital Water & Soil Analysis Kit 5 Parameter (MT-133)    Technical Specifications:- PH Range 0 to 14pH Temp. Comp. 0oC (Manual) Resolution 0.01pH Accuracy +0.01 pH O.R.P./MV Range N.A. 0 to + 1999 mV Resolution 0.01pH N.A. 1 mV Accuracy N.A. + 1 mV + 1 digit Conductivity Range 1 5 Cell Constant 0.4 - 1.5 Adj Resolution 0.1 Micro mhos Accuracy + 0.5% FS Temperature Range 0o - 100oC Resolution 0.1oC Accuracy +0.1oC + digit T.D.S. Range 1 5 Cell Constant 0.4 - 1.5 Adj Resolution 0.1ppm Accuracy +5% FSD D.O. Range 0-20 ppm N.A. Temp. Comp. 0.1 ppm N.A. Resolution +0.3 ppm N.A. Accuracy 5o to 50o (Manual) N.A. Turbidity Range 0-1000 NTU/JTU N.A. Resolution 1 NTU/JTU N.A.      

    more..
  • Water and Soil Analysis Kit

    Water and Soil Analysis Kit

    8,850 - 22,850 Per Kit

    100 Kit (MOQ)

    • Type: Portable
    • Display Type: Remote
    • Voltage: 240 V
    • Application: Industrial , Laboratory
    • Temperature: 40 Deg. C
    • Material: Plastic Body
    more..
  • Soil Analysis

    Soil Analysis

    750 Per sample

    Soil Analysis We are renowned as one amongst the trusted providers of Soil Analysis Services in India. The Soil Sampling Analysis is carried out in our lab and analysis of the soil for pH, EC, Organic Carbon, Available Nitrogen, Phosphorous and Potash is done. In addition to this, the micronutrients like Zinc, Ferrous, Magnesium, Calcium, Free Calcium, Manganese and Boron is also analyzed in the soil. Further, with Soil Fertility Analysis, we also suggest the dosages of fertilizers to be used.

    more..
  • Microprocessor Based Water & Soil Analysis Kit

    Microprocessor Based Water & Soil Analysis Kit

    Get Price Quote

    • Condition: New
    • Power Source: Electric
    • Usage: Household, industrial, Laboratory
    • Material: Steel
    • Finish: Polished

    Avail from us water and soil analysis kits that use the latest microprocessor technology for operation. This product is known for the precise readings and provides results very swiftly and with complete accuracy. These are developed as per the requisite industry standards, and are well accepted by all our domestic and foreign clients. Our range is fabricated using high grade material and latest technology & machines. Technical specification Display 16×2 characters LCD display Ph Ranage 0 to 14 ph Resolution 0. 01 ph Accuracy 0. 01 ± 1 digit Temp. Comp. 0 to 100 ºc (auto /manual) Conductivity (e c) Range 0-20, 0-200µs 0-2,0-20, 0-200ms Resolution 0. 01 ( µs) Range selection automatic Accuracy ± 0. 5 % fs ± 1 digit Cell constant adjustable (0. 05 to 10. 5 ) Temp. Coefficient adjustable ( 0. 4 to 4. 0 ) Temp. Comp. 5- 50º c ( auto / manual) Reference temp. selectable ( 5 – 50º c) Temperature Range 0 - 100º c Resolution 0. 1 º c Accuracy ± 0. 1 º c ± 1 digit Sensor semi conductor type Tds Range 0 – 20, 0 – 200 ppm Range selection auto Resolution 0. 01 ppm Accuracy 0. 5 % fs ± 1 digit a

    more..
  • Digital Soil Analysis Kits

    Digital Soil Analysis Kits

    40,500 Per Kit

    • Brand: Globe Scientific Instruments
    • Accuracy: 0.001 %
    • pH Range: 0-14 pH
    • Voltage: 240 V
    • Frequency: 50 Hz
    more..
  • Water and Soil Analysis Kit

    Water and Soil Analysis Kit

    Get Price Quote

    Water and Soil Analysis Kit that we manufacture, export and supply is very easy to operate by simply putting the F2 switch to standby position and switch on the instrument. The display will indicate 000 at the start. It is advisable to clean the membrane with a soft tissue paper after every use. Our Water and Soil Analysis Kit is appreciated for its accuracy in measurements and portable size. It is available in an easy-to-use kit.   pH Measurements : Put the function switch to pH / Orp mode. Wash the electrode with distilled water and dry it with filter water Connect the electrode BNC plug at the input socket Put the combination pH electrode in buffer solution 7.00 pH. Set the Temp. Knob to the Temp. Of the buffer solution. Now move the switch F2 to pH mode. Read the display value, adjust it with Cal control to 7.00 pH value. Again Move the selector switch F2 to Stand by mode. Take out the electrode from 7.00 pH buffer and wash it with distilled water and dry it with filter paper. Put the electrode in 4.00 pH solution. Set this value to 4.00 pH by setting Slope control. The instruments is ready to take measurements.   O.R.P. Measurements : Put the function Switch F1 to pH/ORP mode. Rinse the CRP electrode with distilled water and dry it with filter paper. Connect the ORP electrode BNC plug at Input socket. Take 0.00 mV buffer solution freshly prepared and calibrate with Cal knob. The instruments is calibrated and ready for taking ORP measurement of any other solution.   Conductivity Measurements : Put the function switch at Cell Const Position Adjust the display to the cell constant value marked on the conductivity cell supplied with the instrument. Now move the switch to the COND. Position Put the range switch at appropriate positions so that best possible resolution is obtained.   TDS Measurements : Put the function switch at TDS Position Clean the conductivity cell, dry it and connect in cond/TDS input socket. Adjust the display to cell constant value marked on conductivity cell by cell const, knob and function switch at Cell const position. Dip the cond. Cell in the unknown solution whose TDS value to be measured. Put the range switch at appropriate PPM/PPT position, so it best possible resolution is obtained.   Cell Constant Measurement : It is recommended that cell constant of the conductivity cell must checked off and on. This can be done as follows : Dip the conductivity cell in a solution of known conductivity. (1408µmhos) Keep the function switch Fat Cond position. Adjust the display to the value of known solution by rotating CE Constant Knob. Bring function switch F to Cell const. Position. The display will indicate the cell constant of the conductivity cell.   D.O. Measurements is done by following steps : D.O. Probe Assembly D.O. Probe consist of a silver and gold electrode cells, an electrolyte tube with thering.   The following procedure may be followed for assembly or D.O. Probe Be careful to handle its membrane. Fit the membrane on the lower part of the electrolyte tube. Fix the ring on the electrolyte tube covering the sides of the membrane. Fill Potassium chloride solution (7.5%) in the electrolyte tube to its top. Insert the electrode in the electrolyte tube and tightly screw it up. Now the probe is ready to use.   D.O. Operation : Put the function switch F1 to D.O. Mode and adjust the display to Co.o with Zero knob and insert the D.O. Probe in D.O. Sockets. Please keep colour code in consideration. Keep the Temp knob to the extreme left position and Cal Knob to extreme right position. Place the D.O. Probe in 2% sodium Sulphite solution. Allow the display to attain equilibrium. If the display does not read 000, set the zero knob to bring the display to read 000 by keeping the temp. Knob to actual temp. Of the solution. Calibrate knob should be at extreme right position. Now Calibrate the instrument with known value of D.O. Solution Take 250 ml. Flash and fill 2/3 of it with distilled water. Stopper the flash and shake it for 30 seconds. Remove the stopper back and siri the water back and repeat the procedure 4 times. Measure the temp. Of the water and set the temp. Knob at temp of water in the flask. Hold do probe in the flash and agitate the water. Note the reading of the display and check the value with that of the table below for given temperature. If necessary adjust the meter reading with CaL knob.   Note : Please refer to the saturation values of the dissolved Oxygen in distilled water as given in Table 1. it shows the values for dissolved oxygen which will be obtained when shaking the distilled water at different temp. In the air. Now the instruments is ready to take measurements of D.O. Value of any unknown solution   Caution : Since the measurement is based on the diffusion process, the agitation of the solution is must. Hand shaking of the solution may not give accurate readings, magnetic stirrer is recommended for this purpose. Movement of the solution should be about 2ft/sec for accurate measurement. BOD bottle is recommended as a container for measurement of sample solution in the laboratory. Because DO probe tight fits in BOD bottle and no atmospheric oxygen may dissolve during measurement.   Maintenance of D.O. Probe : Do not touch the silver electrode of the probe. The Membrane must not have any pin hole, puncture. The DO reading will be erratic at constant DO concentration and temperature, if the membrane has a puncture. Any accumulation of organic matter on the membrane will effect the Cal. It is advisable to clean the membrane with a soft tissue paper after use.

    more..
  • soil analysis kits

    soil analysis kits

    Get Price Quote

    Water and soil analysis kit measured ph, ORP, conductivity, TDS, salinity, dissolved oxygen and temperature (without ORP electrode) Seven parameter. Water and soil analysis kit measured ph, ORP, conductivity, TDS, salinity, dissolved oxygen and temperature (without ORP electrode) Six parameter. water and soil analysis kit measured ph, ORP, conductivity, TDS, salinity, dissolved oxygen and temperature (without ORP electrode) Five parameter. water and soil analysis kit measured ph, ORP, conductivity, TDS, salinity, dissolved oxygen and temperature (without ORP electrode) Four parameter. ACCESSORIES ON REQUEST a) ORP Electrode b) Auto temperature compensation c) Soil probes 30 cm. Length.

    more..
  • Water and Soil Analysis Kit

    Water and Soil Analysis Kit

    Get Price Quote

    • PH MEASUREMENT: O.R.P. MEASUREMENT
    • Range :0 to 14 pH Continuous: Range : 0 to + 1999 mV
    • Resolution :0.01 pH: Resolution : 1 mV
    • Accuracy : + 0.01 pH + 1 digit (relative): Accuracy : + 0.01% + 1digit
    • Temp. Measurement: TDS Measurement
    • Range : -200 to 200 °C: Range : -0 to 100 PPM 0 to 1000 PPM, 0 to 10 PPT, 0 to 100 PPT & 0 to 1000 PPT
    • Resolution : 0.10 °C -: Resolution : 0.1 PPM ( Lowest Range)
    • Accuracy : + 5% of range + 1 digit: Accuracy : + 5% range + 1 digit
    • Sensor Input : PT-100 R.T.D.Type: -
    • Cond. Measurement: D.O. Measurement
    • Range : ( 0 to 1000 mmhos in 5 ranges ): Range : 0 to 20 PPM
    • Resolution : 0.1 micro mho (lowest range): Resolution : 0.1 PPM
    • Accuracy : + 0.5% of range + 1 digit: Accuracy : 5 °C to 55 °C (Manual)
    • Temp. Co-Eft Compn. : Automatic from 0 °C to 70 °C with PT 100 Sensor: Temp. Compn. : 0.2 PPM + 1 digit D.O. Probe : Amperometric Gold / Silver membrane type
    more..
  • Water and Soil Analysis Kit

    Water and Soil Analysis Kit

    Get Price Quote

    A great portable equipment for measuring pH, mV(ORP), Conductivity, temperature, TDS, Dissolved Oxygen (DO), Salinity and turbidity.pH Range: 0 - 14 pH Resolution: 0.01pH Accuracy: ±0.01 pH ±1 digit Temp Compensation: 0-100°C (Manual) Calibration Manual mV (ORP) Range: 0 to ±1999mV Resolution: 1mV Accuracy: ±1mV ±1 digit Conductivity (EC) Range: 0 to 1000 mmho in 5 ranges Resolution: 0.01 umho Accuracy: ±0.5% FS±1 digit Cell Constant: Adjustable (0.4 to 1.5) Reference Temp.: Adjustable (25°C) Temperature: 0 to 100° C Resolution: 0.1° C Accuracy: ±0.5° C ± 1 digit TDS Range: 0 to 10,000 mg/litre Resolution: 10 mgs/litre Accuracy: ±1% FS ±1 digit DISSOLVED OXYGEN (O2) Range: 0 to 20 ppm Resolution: 0.1 ppm Accuracy: ±0.2 ppm ±1 digit Temp. Comp.: 10° C to 50° C (Manual) DO Sensor Gold/Silver Amperometric Calibration Manual SALINITY Range: 0 to 40 ppt Resolution: 0.1 ppt Accuracy: ±0.5% ±1 digit TURBIDITY Range: 0 - 100 JTU Resolution: 1 JTU Accuracy: ±3% FS ±1 digit Sample size: 30 mm glass tube Light: 6.8 V Tungston lamp Detector: Photodiode GENERAL Display 3 1/2 digit (LCD) Operation Temp. 0° to 50° C Housing Materials ABS briefcase Power Supply 230 V ±10%, 50 Hz AC, 9V Battery (Dry cell) Standard Accessories Include the following:pH electrode, Conductivity/TDS/Salinity probe , Temp. probe, DO probe, Set of DO membranes, Test tube for turbidity (3)

    more..
  • Soil Analysis Kit

    Soil Analysis Kit

    Get Price Quote

    Digital water & soil analysis kit npc 361d: lcd display for ph,orp,tds,salinity, conductivity.dissolved oxygen & temperature . Main cum battery operation with inbuilt abs briefcase.complete with standard accessories.

    more..
  • Soil Analysis Kit

    Soil Analysis Kit

    Get Price Quote

    Water and Soil Analysis Kit (1072) • Measures pH, Conductivity,TDS, DO, Salinity, mV & Temperature • Turbidity measurement • Turbidity measurement • Available in 3 ½ digit LCD display

    more..
Filter by City
top