Solvent Recovery System Dealers

(42 products available)
  • Industrial Chemical Recovery Unit

    Industrial Chemical Recovery Unit

    345,000 Per Piece

    1 Piece (MOQ)

    • Material: Mild Steel
    • Driven Type: Electric
    • Condition: New
    • Automatic Grade: Automatic
    • Application: Industrial
    • Voltage: 340-380 V
    • Brand Name: Pragmatic
    • Type: Solvent Recovery System
    • Country of Origin: India
    • Frequency: 50-60 Hz
    more..
  • Solvent Recovery System

    Solvent Recovery System

    Get Price Quote

    1 Piece (MOQ)

    • Driven Type: Electric
    • Automatic Grade: Automatic
    • Power: 3-5kw
    • Application: Industrial
    • Voltage: 440V
    • Warrenty: 1year

    Discover the transformative potential of Solvent Recovery Systems by K-Jhil. Designed to reclaim and recycle solvents from industrial processes, our cutting-edge facilities offer a sustainable solution to solvent management. By capturing and purifying solvents for reuse, our systems reduce waste and significantly lower procurement costs for businesses. Experience the versatility and efficiency of Solvent Recovery, seamlessly integrating chemical reaction and distillation in a single unit. From esterification to dehydration, our technology caters to diverse industries, including petrochemicals, pharmaceuticals, and specialty chemicals. Join the sustainable revolution with K-Jhil’s Solvent Recovery Systems.Salient Features : Distillation Units : Distillation is a common method for solvent recovery. The used solvent is heated in a distillation unit, and the vapor is collected and condensed back into a liquid. This process separates the solvent from impurities or contaminants. Condenser and Coolers : These components are crucial for converting the vaporized solvent back into a liquid form. They help in the separation of the purified solvent from other substances. Recovery Columns : Recovery columns enhance the separation of different components within the solvent mixture. They help improve the efficiency of the distillation process. Filtration and Purification Systems : Filtration systems remove solid impurities or particulate matter from the solvent. Additional purification methods may include adsorption or chemical treatments to remove remaining contaminants. Storage Tanks : Recovered and purified solvents are typically stored in tanks before being returned for reuse. Proper storage is important to maintain the quality of the recovered solvent. Monitoring and Control System : Automated systems monitor and control various parameters such as temperature, pressure, and flow rates to ensure the efficiency and safety of the solvent recovery process. Applications : Pharmaceutical Industry : Solvent recovery is crucial in pharmaceutical manufacturing processes. Chemical Industry : Used for the recovery of solvents in various chemical processes. Manufacturing Sector : Common in industries where solvents are utilized for cleaning and processing.

    more..
  • Best Deals from Solvent Recovery System

  • Energy Recovery System

    Energy Recovery System

    Get Price Quote

    1 Piece (MOQ)

    • Driven Type: Electric
    • Application: Industrial
    • Voltage: 220V
    • Color: Black, Grey
    • Certification: CE Certified
    • Country of Origin: India
    more..
  • Solvent Recovery Unit

    Solvent Recovery Unit

    Get Price Quote

    A cost effective system for recovery of >99% pure solvent from mother liquors consisting of moisture, dissolved solids, chemical residues, etc. * provided on design equipment supply turnkey basis * capacity of 200 lph to 2000 lph of solvent working successfully * recovery units provided for solvents such as methanol, acetone, acetic acid, etc.

    more..
  • solvent recovery systems

    solvent recovery systems

    Get Price Quote

    We use premium-packaging materials to safeguard our products from mechanical and environmental conditions. For our patrons, we offer customized packaging solutions as well. Owing to the complete help of our dexterous staff, we present products that are certified as in conformance with the set norms.

    more..
  • Solvent Recovery Unit

    Solvent Recovery Unit

    Get Price Quote

    • Application: Solvent Recovery
    • Voltage: 220V
    • Driven Type: Electric
    • Warranty: 1 Year
    • Brand Name: Alfa
    • Type: Automatic
    • Certification: CE Certified
    more..
  • Solvent Recovery System

    Solvent Recovery System

    Get Price Quote

    • Material: metal
    • Brand Name: Rufouz Hitek
    • Automatic Grade: Automatic
    • Application: industrial
    • Design Type: Standard, Customized
    • process: Solvent Extraction
    more..
  • solvent recovery systems

    solvent recovery systems

    Get Price Quote

    Gasoline vapour recovery systems designed, engineered and manufactured by Kilburn are backed by Kilburn's extensive experience in process design, detail engineering and supply of adsorption systems and skid mounted units.

    more..
  • Solvent Recovery Stripper System

    Solvent Recovery Stripper System

    Get Price Quote

    1 Piece (MOQ)

    • Weight: 100-1000kg
    • Voltage: 220V
    • Automatic Grade: Automatic
    • Power: 1-3kw
    • Driven Type: Electric
    • Country of Origin: India
    • Warrenty: 1year

    Stripper systems are used to recovering low boiling solvents from wastewater. By using stripper, COD reduces in MEE Plant condensed water.

    more..
  • Solvent Recovery System

    Solvent Recovery System

    Get Price Quote

    • Power: 5 kilowatt
    • Weight: 5 ton
    • Capacity: 5-10 Litre per hour
    • Automation Grade: Automatic
    • Country of Origin: Made in India
    more..
  • Solvent Recovery System

    Solvent Recovery System

    Get Price Quote

    Brofind specializes in the treatment of volatile organic compounds contained in the emissions of industrial processes. They provide special solutions ranging from the design and engineering to complete turnkey plants for the most common technologies: solvent recovery systems with activated carbon and traditional, catalytic or thermal, recuperative or regenerative oxidizers. Brofind can boast prestigious references in various industries, such as printing (flexographic, rotogravure, roto-offset, etc.), coating and lamination of flexible packaging, adhesive tapes, painting and coating.

    more..
  • Energy Recovery System

    Energy Recovery System

    Get Price Quote

    Devatech is a leading globel provider,as a world market leader we continuously push technology forward. The combination of heat and humidity recovery of rotary heat exchangers is a highly efficient energy-saving. This is not a formula but is a Technology.

    more..
  • Solvent Recovery Unit

    Solvent Recovery Unit

    Get Price Quote

    • After-Sales Service Provided: 3 year service

    Chemical free operation, simple, easy and savedigital timer for light finishing controlphilips uvc high intensity lamps equippedwith powerful air exhausting for big size models solvent recovery systems advantages : • reduce your solvent disposal costs and wastewater treatment surcharges • 1 year or better payback on most solvent recycling • equipment sized to meet the needs of small users, and the largest industrial plants. • with new, used, and refurbished options, we can usually find a system to fit your budget. • technical help with setting up and training to use the solvent recycling systems • we won’t forget you after the sale. # operating steps after opening the crate, plug in 220 v power, and connect the ground (earth). Open the lid and fill the tank up to the level with solvent to be recovered (80 l) close the lid and tighten it. Check all the pipe hose make sure it is well connected. Especially vacuum pipe (6) and fresh come-out pipe(1). Set up the thermostat(18) for example for perc.is 150 degree c, for green chemical is 160-210 degree c. Vacuum tank pressure(3) high at 0.03 mpa low at 0.01mpa, and steam cooling fan thermostat(11) at 40 degree c. Turn on the power switch(15), steam cooling switch(16), heater switch(17) and vacuum pump switch(12). If you want to be controlled with timer, it depends on the quantity of the chemical, set up the timer(14) then turn on the switch(13). # important install the unit in a wide and ventilated place disconnect electric power before doing any action no taking off the control panel change the diathermic oil every 1000 working hours no filling the solvent container up over the level (80 liters) remove the waste after every recovery process recovery time 3 o 4 hours

    more..
  • Solvent Recovery System

    Solvent Recovery System

    Get Price Quote

    We have built more than 20 on-site recovery systems. The innovative PESCO BEAM system recovers the usable solvent from the waste, then cleans and prepares the product for reuse by the factory which generates it. This saves the client money in solvent purchases, waste disposal, and environmental and public health liability.Our Systems include thin film and forced circulation evaporators, plus fractionation columns operating at pressure or under vacuum.

    more..
  • Solvent Recovery System

    Solvent Recovery System

    Get Price Quote

    • Voltage: 420V
    • Material: Mild Steel
    • Temperature: 0-300 Degree C
    • Features: Low power consumption, Rugged design , Flawless performance
    • Capacity: 5-50 KLPD
    • Automation Grade: Automatic
    • Surfase Finishing: Color Coated
    more..
  • Solvent Recovery System

    Solvent Recovery System

    Get Price Quote

    Solvent Recovery System provides cost effective recycle and reuse of liquid solvents. We are a trusted Importer, Supplier and Exporter of Solvent Recovery System. Our Solvent Recovery System is designed for handling 25-250 gallons per hour and is the simplest and high performing system. The offered System is composed of a non-scraped vessel with a 70 cone design, which incorporates a unique steep walled distillation chamber. It is surrounded by a large volume oil bath heated with electric immersion heaters or optional steam coils. Our System has excellent heat transfer capacity.

    more..
  • solvent recovery systems

    solvent recovery systems

    400,000 Per Piece

    • Voltage: 230V
    • Model Name/Number: Di 15 Ax
    • Dimension: 55 x 65 x 165 cm
    • Working Temperature: 50-180 degC
    • Loading Capacity: 15 ltr
    more..
  • Brine Recovery System

    Brine Recovery System

    Get Price Quote

    • Automation Grade: Automatic
    • Temperature (deg. Celsius): 80
    more..
  • Solvent Recovery System

    Solvent Recovery System

    Get Price Quote

    This is designed for recovery of flexographic photopolymer plate solvent washout chemical and any environmental green chemical with specialties of distilling and cooling can be connected with in-line processor and any plate washout machine directly. With cold air circulation and drain out of residue for high speed recovery. Super recovering rate in the shortest time, is an ideal and high efficient recovery unit for flexographer.   B. Technical information: Recovery volume: 100 litersPower consume: 220V AC 6.65KWDiathermic oil: 40 KGMachine dimension: Main body: 1500x 980×1500 mmRecovery rate: 85%Recovery time: 3 ~ 4 hours   C. Operating steps: 1. After opening the crate, plug in 220 V power, and connect the ground (earth).2. Open the lid and fill the tank up to the level with solvent to be recovered (100 L) 3. Close the lid and tighten it.4. Check all the pipe / hose make sure it is well connected. Especially vacuum pipe (6) and fresh come-out pipe (1).5. set up the thermostat (18) for example for Perc. Is 150 degree C, for green chemical is 160-210 degree C. Vacuum tank pressure (3) high at 0.03 Mpa / low at 6.01Mpa, and steam cooling fan thermostat (11) at 40 degree C.6. Turn on the power switch (15), steam cooling switch (16), heater switch (17) and vacuum pump switch (12).7. If you want to be controlled with timer, it depends on the quantity of the chemical, set up the timer (14) then turn on the switch (13).   D. Important: 1. Install the unit in a wide and ventilated place.2. Disconnect electric power before doing any action.3. No taking off the control panel4. Change the diathermic oil every 1000 working hours.5. No filling the solvent container up over the level (100 liters)6. Remove the waste after every recovery process

    more..
  • Solvent Recovery System

    Solvent Recovery System

    Get Price Quote

    Two well known names AMCEC, USA and Dalal Engineering, India have come together to offer perfect solutions in the field of Solvent Recovery. So you get the benefit of AMCEC’s established technological expertise and Dalal’s proven engineering skills. AMCEC is a recognized leader in the fields of vapor phase solvent adsorption using activated carbon and solvent recovery. It has over 80 years of worldwide experience, and with thousands of systems in operation, helps companies recover millions of kilos of solvent VOC’s each year.

    more..
Filter by City
top