SiteMaster 2-Wire Decoder Controller
Get Price Quote
1 Carton (MOQ)
2-Wire Decoder Controller Features Number of stations: Up to 99 Weather station capable Connect up to 2 hard-wired flow meters and 3 additional meters attached to decoders in the field Rain sensor and rain/freeze sensor ready 6 independent programs with 6 start times each Full on-screen keyboard makes naming and programming easy and intuitive Advanced diagnostics include interactive fault log, decoder signal strength/status Largest screen in the industry displays run times, watering days, number of start times Two fully independent wire paths for easy layout design and trouble shooting Special features include seasonal adjust, station/zone grouping, program backup and restore Station delay/overlap and pump pressurization allows dual operation and pressurization for each of 5 separate pump start locations Vandal-resistant lockable housing Specifications OPERATING SPECIFICATIONS Station Run Times: 1 second to 9:59:59 Programs A, B, C, D, E, & F Start Times: 6 per program Watering Schedule: 7 Day Calendar (any day of the week), odd/even days, interval watering up to 31 days Operating Temperature: 0°–140° F (18°–60° C) Zone Capacity: 99 zone groups limited to 6 zones and 1 MV/PS per primary line. Add up to 12 zones (A and B total). Pump Start Requirements: Pump Starts wired directly to the controller require a K-Rain 1520 or 1510 mini coil power relay. Remote pump start relays on the 2-wire path require a K-Rain 3410 Optical Pump Start Relay in conjunction with a K-Rain 1520 or 1510 mini coil power relay. ELECTRICAL SPECIFICATIONS 2-Wire transformer; Input: 120/240 50/60 Hz Max Output: 27 VAC 100VA 3.7 AMP Midbox Transformer; Input: 120/240 50/60 Hz Max Output: 24 VAC 40VA 1.71 AMP Battery: 2032 Coin Cell (included) 9V alkaline battery (optional, not included) Models 3400 110 VAC 2-wire decoder controller 3400-220 220 VAC 2-wire decoder controller 3420 110 VAC 2-wire decoder controller in stainless steel cabinet 3420-220 220 VAC 2-wire decoder controller in stainless steel cabinet 3421 110 VAC 2-wire decoder controller on stainless steel pedestal 3421-220 220 VAC 2-wire decoder controller on stainless steel pedestal *Above models include 3403 2-wire module.
2-Wire Ultrasonic Level Transmitter
Get Price Quote
We are well- known Supplier of Wire Ultrasonic Level Transmitter. The Wire Ultrasonic Level Transmitter is fabricated using high-grade material. Owning to its superior quality, effective performance and durability, TheTtwo Wire Ultrasonic Level Transmitter is widely used in beverages, wastewater, chemicals, oils, etc. Applications Food Beverages Water and waste water Chemicals Oils Features Simple push-button calibration Output 4-20 mA ,20-4 mA Built-in temperature compensation Compact Size for Easy Mounting
Best Deals from Two Wire Transmitter
two wire transmitter
Get Price Quote
Two wire transmitter in mechanical and system engineering. Series includes universal inputs, which combines flexible input selection on site. A unique data storage feature using dot-matrix printer provides a digital value records thus eliminating the maintenance cost involved with chart paper and pens.
PH 2-wire Transmitter MODEL 873
Get Price Quote
Pantech Instrument’s 2-wire Transmitters, Model 873, are designed to provide 4-20 mA DC signal on the same two wires which carry the 24 V DC power for measurement of pH. The transmitter is an ideal choice for on line pH measurement using any industry standard combined gas electrode. It provides a current output signal capable of driving load upto 650 ohms. This allows pH measurement at a distant place from the control room all the time. The temperature compensation is built in and the process temperature is measured by RTD. The compensation is provided over the complete range of 0-100 deg. C. The instrument can be calibrated throughout the range of 0-14 pH with a minimum span of 2 pH. The transmitter is available in field mounted housings with or without local digital display
2 Wire Temperature Transmitter
Get Price Quote
Isolated transmitters 1000/1500 VRMS isolation 12-36 VDC power supply True 2-wire transmitter Ground loop elimination DIN RAIL Mounting : 75H x 46W x 110D, mm.
Two Wire Temperature Transmitter
Get Price Quote
Featuring state-of-the-art integrated circuits and electronic design, our Two Wire Temperature Transmitter are designed to fit inside many compact thermo well protection heads. The company is a renowned Manufacturer and Supplier of Two Wire Temperature Transmitter in Gujarat. The Two Wire Temperature Transmitter offered has a diameter of only 45mm. Our Two Wire Temperature Transmitter converts mill volt input from thermocouples or resistance from RTD or potentiometer into 4 to 20 ma output.Details : A stable 4 to 20 ma output signal is produced proportional to the transmitter’s specific input type and calibrated temperature range. Adjustability of zero and span is provided to facilitate some range ability. The transmitted signal eliminates noise pickup, voltage drops and multiple cold junction errors, and it requires only a twisted pair of copper wires for loop connections. All models and ranges of these ultra-miniature transmitters are available with fully epoxy-potted electronics, which gives ultimate protection in extreme environmental conditions.   Specifications : thermocouple and rtd field selectable resistance input predefined miniature size fits in sensor protection head all parameter settingcalibration through communicator 4 to 20ma dc output at 500ohms loading capacity upscaledown scale field selectable Accuracy better than +-0.2 % of span Ambient temp. range : -10 to 50oc Supply voltage : 15 to 30vdc, 24vdc recommended max loop Dimensions : 45 d * 15mm h (15+10mm, height includes terminal strip) Weight : 100gms. approx
Radix RH+T 2 Wire Transmitter
Get Price Quote
Two Wire Temperature Transmitter
Get Price Quote
We are engaged in offering Two Wire Temperature Transmitter. Which are designed to fit inside many compact thermo well protection heads. These products are in huge demand all over the world due to compact sizes.
Two-Wire Capacitance Continuous Level Transmitter
Get Price Quote
Applications : • Free flowing homogeneous liquids like oil, Raw water, WFI, DM/DI water etc.• Suitable for top mounting• Process temperature max. 2000C.• Process pressure max. 20 bar.• Suitable for corrosive liquids.   Features : • Compact size• Rigid rod/flexible rope versions• Wide range industrial dc power supply (12 to 60 VDC)• Loop powered device (true-two wire)• No potentiometers - hassle free calibration• Various customized process connections like Threaded / Flanged / Hygienic etc.• Water bed sensing for oil/fuel/fatty-acid applications
two pegs wire tightener
Get Price Quote
Wire Transmitters
Get Price Quote
TR series vibration transmitter uses advanced LSI technology that integrate the signal conditioning, processing and outputting circuitry into one integral unit. It can directly replace the probe driver and connect to the proximity probe and extension cable, converting the signal to a 4-20 mA output. Buffered dynamic output is available for additional analysis.
Two Wire Head Mount Transmitters
Get Price Quote
Description : Since the signals generated by thermocouples or resistance sensors are low on emf and resistance, they can be transmitted over a short distance using compensating and three wire cables, without the loss of signal strength and accuracy. However, to transmit signals over very long distance without loss of accuracy, Two Wire loop transmitters are widely used. The low level signal converted to 4-20mA current output can be transmitted over long distance using a pair of normal copperwire. Accuracy of output current shall be independent of the lead resistance and length of the cable. The transmitter, fits directly into standard terminal head both weather proof or Ex-proof. Application : For converting thermocouple or Pt-100 or resistance signal to equivalent 4-20mA signal for long distance transmission.
Two-Wire Capacitance Level Transmitter (TLC)
Get Price Quote
Operating Principle : TLC2 probe surface forms a capacitance with the walls of tank containing the liquid Level sensing probe gets divided into three parts - Stray capacitance Cstray Air part forming Cair Liquid part forming Cliq When level increases, Cliq increase, Cair falls while Cstray stays constant as probe/device is held at fixed location with respect to the tank. While, with level decreasing, Cair increaeses while Cliq falls, so in effect measuring capacitance provides information about liquid level in the tank. Software inside the device holds the higher and lower calibration values, and provides level information on the device output Features : Fast Switching Response High temperature endurable probes Single sensor allows pump-control & multi-point switching Easy calibration with or without material Remote electronics with std 10 meters cable length External indication LED available Threaded , Flanged Mountings & TC Electronic Inserts support all requirements Ingress protection : IP 68/65 (as per IS-13947) Ex-proof (Ex d T6 IP-66 IIC) Flameproof as per IS/IEC 60079-1:2007 Weatherproof (IP-66) as per IS/IEC 60529:2001 Suitable for Gas Group : IIC Suitable for Zone 1 & 2 atmospheres Compact size Rigid rod / flexible rope versions No potentiometers - hassle free calibration compensation against material build-up Applications : Free flowing homogeneous liquids like oil, raw water, WFI, DM/DI water etc Suitable for top mounting Process temperature max. 200°C Process pressure max. 20 bar
Aqua 2-wire series SMARTPro transmitter
Get Price Quote
Forbes Marshall, the pioneers in Water Quality analysers in India introduces the Aqua SMARTPro Series, an in-house developed microcontroller based 2-WIRE HART Transmitter which assures continuous and reliable measurement of parameters like pH, Redox, Dissolved Oxygen, Conductivity and Resistivity which are of vital importance spread across the entire spectrum of process and water measurements.
Two Wire Head Mount Transmitters
Get Price Quote
Since the signals generated by thermocouples or resistance sensors are low on emf and resistance, they can be transmitted over a short distance using compensating and three wire cables, without the loss of signal strength and accuracy. However, to transmit signals over very long distance without loss of accuracy, Two Wire loop transmitters are widely used. The low level signal converted to 4-20mA current output can be transmitted over long distance using a pair of normal copperwire. Accuracy of output current shall be independent of the lead resistance and length of the cable. The transmitter, fits directly into standard terminal head both weather proof or Ex-proof. APPLICATION : For converting thermocouple or Pt-100 or resistance signal to equivalent 4-20mA signal for long distance transmission.
Two Wire Level Transmitter
Get Price Quote
SITRANS Probe LU 2-wire loop powered ultrasonic transmitter
Get Price Quote
SITRANS Probe LU is a 2-wire loop powered ultrasonic transmitter for level, volume and flow monitoring of liquids in open channels, storage vessels, and simple process vessels.
Configurable 2-wire Temp. Transmitter
Get Price Quote
4 ~ 20 mA output, two-wire connection• SMD Technology Construction• Bulk Head Mounting
Two-Wire, Capacitance Type Level Transmitter
Get Price Quote
All free flowing liquids, solids, powders and grains. Suitable for top mounting. Temperature up-to max. 200'C. Process Pressure up-to max. 20 bar. Suitable for corrosive liquids. No Potentiometers- Hassle free calibration.