Uv Flame Detector
Get Price Quote
1 Piece (MOQ)
UV-IR Flame Detector
Get Price Quote
1 Piece (MOQ)
Best Deals from UV Flame Detector
Ultraviolet Flame Detectors
Get Price Quote
1 Piece (MOQ)
UV-FLAME-DETECTOR
Get Price Quote
Highly Sensitive - detects cigarette lighter flame from 5 meters. Flame detection exceeding 50 meters. Scans an area instead of spot detection. Fast Response Time. Solar and artificial light blindness. Rugged electronic, module. Weather Proof / Explosion proof housing. Design for used in hazarduous /non hazarduous locations. Low power consumption 12/24 VOC or 220 VAC Operation
Uv Flame Detector
7,500 Per Piece
Siemens UV Cell
7,524 Per Piece
1 Piece (MOQ)
Uv Flame Detector
Get Price Quote
Honeywell C7027A UV Flame Detector
Get Price Quote
Uv Flame Detector
Get Price Quote
The HNL Flame Detector is a compact and highly responsive Flame / Fire Detector. The Unit incorporates an extremely sensitive sensing circuit that responds to high energy sources in a bandwidth of 185 – 260 nm with optimum spectral sensitivity centred around 200 nm.Thus HNL Flame Detector is the most effective in early detection of a fire before they can possibly cause damage. In contrast, other types of detectors operate at a disadvantage. Smoke detectors do not operate until the fire has developed into a sufficient size to accelerate smoke along with strata of hot air rising to the detector.It is particularly suitable for use in outdoor applications because it is not affected by wind or rain. Various modelsto detect & control the presence or absence of flame are available.
IR and UV Flame Detector
150,000 Per Piece
1 Piece(s) (MOQ)
Siemens UV Flame Detector
Get Price Quote
1 Piece (MOQ)
Uv Cell or Flame Detector
Get Price Quote
We are offering uv cell or flame detector, furnace uv cell for gas burners.
Uv Flame Detector
Get Price Quote
Built-in single chip microcomputer for signal processing and intelligent communication control* Intelligent algorithm for fast alarm, response and superior false alarm rejection* Connect directly to GST addressable loop, compatible with all GST intelligent panels* Three (3) sensitivity levels* High sensitivity and reliable performance, dust/corrosion/humidity resistant* Adapted to explosive area 1&2
FlameGard 5 UV/IR Flame Detector
Get Price Quote
The precision-crafted FlameGard® 5 UV/IR Flame Detector monitors both ultraviolet and infrared (UV & IR) spectral ranges, which makes it highly immune to false alarms caused by lightning, arc welding, hot objects and other sources of radiation. The unit's Continuous Optical Path Monitoring (COPM) checks both the optical path integrity and the detector's electronic circuitry once a minute, while the wide field of view enables greater fire detection coverage. Wide operating temperature range permits operation at higher ambient temperature 4-20 mA stepped output is the industry standard for remote alarm and fault indication Modbus and HART user interface provides complete status and control capability in the control room Three SPDT 8A programmable relay outputs provide immediate and time-delayed relay outputs for alarm, warning and fault conditions Event logging stores fault and alarm history.
Uv Flame Detector
Get Price Quote
Dual LED for 360 degree visibility – 02 wire based model – Easy installation and maintenance – High sensitivity and wide directivity – Sleek low-profile housing design – Quick detection of flame from Distance – SMD circuit board design-satisfactory quality and reliability guaranteed
Uv Flame Detector
Get Price Quote
This test unit has been designed to generate a wide range of optical output signals. Flame sensors for fire detection and flame monitoring applications can be activated and tested. Most optical flame sensors respond to Ultra Violet (UV) and or InfraRed (IR) radiation emitted from flames during combustion. Many sensors also use flame flicker techniques to distinguish between flames and other optical false sources. The test unit simulates the flickering flame signal by modulating the output of a filament lamp. The thermal time constant of a filament lamp prevents the generation of a perfect flame flicker signal. The slow response of the filament lamp will mean that some flame sensors many require more time to activate under test than they would with a real flame. Ideal for testing flame detectors Wide Spectral Output - UV, Visible, Near IR, Mid-IR Tests many Flame Sensors Types UV, UVIR, UVIR², IR³, IR², IR Conforms to NFPA 72 Chapter 14 (14.4.3) Portable with Rechargeable NiCd Battery Pack and Charger 12V 7 Ah maintenance free leak proof sealed battery Selectable Optical Output Type Constant Illumination Regular Flashing Sources (Range of Frequencies)
Honeywell UV Flame Detector
11,000 Per
UV IR Flame Detector
36,000 Per Piece
Honeywell UV Flame Detector
200,000 Per Piece
5 Piece (MOQ)
Uv Flame Detector
Get Price Quote
These flame detectors give the highest immunity to false flame sources both indoors or out. They have internal self-test sources that check the detector’s operation when remotely instructed. The maximum ambient temperature is normally 55°C or 85°C for the higher temperature specification detectors.Detects invisible flames from fuels such as Hydrogen and other inorganic fuels.