High Voltage Insulator Breakdown Tester
18,400 Per piece
1 piece (MOQ)
high voltage breakdown tester -model - ces 407range - 0 - 5kv ac / 100macurrent limit : settable from 10% to 100% through continuously variable controlmeter : two digital meters to monitor voltage & leakage currentaccuracy : ±1% of readingpower requirement : 230vac optional:timer : 3 digit, setable from 0-999sec
HVT 1530 High Voltage Tester
24,500 - 28,500 Per Piece
1 Piece(s) (MOQ)
Best Deals from Voltage Tester
Fence Voltage Tester
Get Price Quote
100 Piece (MOQ)
We Provided Neon Tester in havy Quality and Low Market Price. Eight-Neon-Light graduated solar fencing Neon-Tester actually shows how many volts are at the charges or on the fence live line. Voltages are plainly marked on the casing: 1300V, 2600V, 3900V, 5200V, 6500V, 7800V, 9000V and 10000V. Galvanized spring steel wire earth stake. Handy pocket clip.
High Voltage Breakdown Tester
Get Price Quote
Model: cie / 5050a application 'cie' a.c. High voltage breakdown test set is ideal for fast accurate & reliable testing of withstand/breakdown test of electrical & electronic materials, components, equipments, panel boards, etc. salient features robust powder coated sheet metal case elegant look kv meter to read the output voltage millimeter to show leakage current speedy and accurate testing of breakdown/withstand test of electrical & electronic components, materials, equipments, panel board etc. technical specifications input voltage : 230v, +/- 10%, 50hz, 1 phase a.c. output voltage : continiously variable from (i) 0 to 3 kv ac for 3 kv test set (ii) 0 to 5 kv ac for 5 kv test set
Helmet Mounted Voltage Tester
Get Price Quote
200 Piece (MOQ)
High Voltage Cable Tester
Get Price Quote
We offer High Voltage Cable Tester that is fully computer controlled. It is used as a pass or fail test for cables. Small size, lightweight, large screen LCD, test report, and easy usage are the prime highlights of our High Voltage Cable Tester. Available at very feasible prices, High Voltage Cable Tester comes in different specifications to suit all the requirements of our customers. Highlighting Features : Data of current and voltage are obtained directly through the sampling of High-Voltage side and it is true and accurate. Over-voltage protection: the instrument will shut down to protection within 20 ms when the output voltage is exceeding limiting values of setting. Over-current protection: designed for dual protection of high and low voltage, downtime protection can be accurately set in high-voltage side. Shut down to protection times is within 20 ms when the current of low-voltage sides exceeds reacted current. High-voltage output protection resistor design in inbuilt and there is no need of additional external resistor.
high voltage test set
25,000 - 5,000,000 Per Piece
1 Piece(s) (MOQ)
Every electrical apparatus or machine Is provided with insulation between live part and earth or between two different sections of live parts. This insulation is required to be tested at high voltage values recommended by applicable relevant standards. The standard Specification for various electrical apparatus specifies Power Frequency Voltage withstand test at different levels depending upon working voltage of electrical apparatus. It is observed from the various standards for electrical equipments that the minimum power frequency voltage withstand test level for electrical insulation is 2kV for one minute. We have, therefore, standardized on manufacture of’AE’ High Voltage Breakdown Testers with rated voltage of 5kV. High Voltage Tests Sets of higher voltage upto 600kV are also manufactured against specific requirement. The standard voltages are 10kV, 15kV, 20kV, 25kV, 30kV, 50kV,100kV, 150kV, 200kV & 300kV. The test sets uplo 30kV are manufactured in Air Cooled design while the sets of 50kV & above are manufactured in Oil Cooled design. The output of these high voltage testers is single phase 50/60Hz. The standard H.T. current rating of air-cooled design as also of oil cooled design upto 150kV is 100mA for 30 minutes. For voltages ranges above ‘AE’ make 5kV A.C. (with 2.5kV tap) High Voltage Breakdown Tester is portable, sturdy & plug in to start type construction & requires minium table space. It broadly consists of 3 main sections. High Voltage Transformer : The High voltage transformer is single phase, single pole type & is of double wound resin moulded construction. The H.T. winding is provided with graded insulation such that one end is insulated for 2kV insulation and is earthed through a current sensing transformer & miiliammeter whereas other end isinsulated for full rated voltage & the same brought out through H.T. Cable & spring loaded Prod. Variable Voltage Source : Variable Voltage supply is provided through a Dimmerslat (Variable auto-transformer) havingasuitable rating corresponding to the rating of H.V. Transformer. Dimmerstat Is rated for 230Volts A.C. input & 0-270V output. Limit switch at zero position end of Dimmerstat winding is provided to facilitate the H.T. winding to. Control Circuit & Other Features : ManuaIly operated control transformer (VariabIe auto-transformer) with zero interlock facility. 72mm sq. double range (0-2kV / 0-5kV) moving coil rectifier type voltmeter of class 1.5, provided to read NO LOAD H.T. Voltage. 72mm sq. double range (0-100mA) moving coil rectifier type A.C. Milliammeter of class 1.5, provided in the earth end of the H.T. winding to read H.T. Current. Automatic tripping circuit is provided for isolation of supply, in the event of failure of the object under test. Rotary switch with four different settings of 5,10, 50 & 100mA is provided on front panel with LED indication M.C.B. for short circuit protection of H.T. transformer & auto transformer H.T. ON push button, Mains ON & H.T ON LED indication. Range selection switch to select 2.5kV or 5kV range with LED indication. Two spring loaded test prods with 1 metre long cable for safe & easy connection of high voltage to test object, (upto 5kV.)
Kyoritsu 5kV High Voltage Insulation Tester
68,550 Per Piece
1 Piece (MOQ)
High Voltage Breakdown Tester
Get Price Quote
1 Piece (MOQ)
Every electrical apparatus or machine is provided with insulation between live part and earth or between two different sections of live parts. This insulation is required to be tested at high voltage values recommended by applicable relevant standards. The standard Specification for various electrical apparatus specifies Power Frequency Voltage withstand test at different levels depending upon working voltage of electrical apparatus. It is observed from the various standards for electrical equipment’s that the minimum power frequency voltage withstand test level for electrical insulation is 2kV for one minute. We have, therefore, standardized on manufacture of’ MARSZ High Voltage Breakdown Testers with rated voltage of 5kV. High Voltage Tests Sets of higher voltage upto 600kV are also manufactured against specific requirement. The standard voltages are 10kV, 15kV, 20kV, 25kV, 30kV, 50kV, 100kV, 150kV, 200kV & 300kV. The test sets upto 30kV are manufactured in Air Cooled design while the sets of 50kV & above are manufactured in Oil Cooled design. The output of these high voltage testers is single phase 50/60Hz. The standard H.T. current rating of air-cooled design as also of oil cooled design upto 150kV is 100mA for 30 minutes. For voltages ranges above ‘MARSZ’ make 5kV A.C. (with 2.5kV tap) High Voltage Breakdown Tester is portable, sturdy & plug in to start type construction & requires minimum table space. It broadly consists of 3 main sections. High Voltage Transformer: The High voltage transformer is single phase, single pole type & is of double wound resin moulded construction. The H.T. winding is provided with graded insulation such that one end is insulated for 2kV insulation and is earthed through a current sensing transformer & mill ammeter whereas other end is insulated for full rated voltage & the same brought out through H.T. Cable & spring loaded Prod. Variable Voltage Source: Variable Voltage supply is provided through a “VARIVOLT” (Variable auto-transformer) having a suitable rating corresponding to the rating of H.V. Transformer. Dimmerstat Is rated for 230Volts A.C. input & 0-270V output. Limit switch at zero position end of Dimmerstat winding is provided to facilitate the H.T. winding to Control Circuit & Other Features: Manual operated control transformer (Variable auto-transformer) with zero interlock facility. 72mm sq. double range (0-2kV / 0-5kV) moving coil rectifier type voltmeter of class 1.5, provided to read NO LOAD H.T. Voltage. 72mm sq. double range (0-100mA) moving coil rectifier type A.C. Mill ammeter of class 1.5, provided in the earth end of the H.T. winding to read H.T. Current. Automatic tripping circuit is provided for isolation of supply, in the event of failure of the object under test. Rotary switch with four different settings of 5,10, 50 & 100mA is provided on front panel with LED indication M.C.B. for short circuit protection of H.T. transformer & auto transformer H.T. ON push button, Mains ON & H.T ON LED indication. Range selection switch to select 2.5kV or 5kV range with LED indication. Two spring loaded test prods with 1 meter long cable for safe & easy connection of high voltage to test object, (upto 5kV.)
Breakdown Voltage Tester
Get Price Quote
Breakdown Voltage Tester is ideal for measuring the breakdown voltage of the electrical components, transformers and insulation material instruments. It also helps in determining the quality of insulating material prior to their utilization in various electrical applications. This method of test is intended to find the breakdown voltage of the liquid insulating materials like transformer oils, synthetic insulating materials etc. in liquid form. The maximum test voltage to which the test can be carried out with this instrument is up to 11 KV Details : Failure will occur during this test when voltage is applied between the electrodes and the breakdown voltage value is less than the maximum available test voltage. The insulating material when subjected to electrical stress, will experience a force on its molecular bonds which will break these bonds rendering the material conducting, thereby causing the failure. For accuracy reason, to find the breakdown voltage value of an insulating materials like magnet wires, various statistical methods like averaging, mean readings etc. are used. We are enlisted among the prominent Manufacturers, Exporters and Suppliers of Breakdown Voltage Tester from Maharashtra, India. The Breakdown Voltage Tester that we offer is manufactured in tandem with the Indian and International Electro-technical Commission standards.
Digital High Voltage Insulation Tester
5,000 Per Piece
Buyers can stay rest assured for damage-free products from our end as we make use of quality packing material. We also fulfill different packing requirements of the clients such as customized or standard. Our company has all the necessary logistic resources and connection to make on time delivery of order(s). Product Details : Easy and Simple Operation Automatic range,indicated by different Leds Safety standard IEC 61010-1CAT IV 300V 1Ohm 100GOhm
Digital High Voltage Tester
Get Price Quote
10 Piece (MOQ)
High Voltage Insulation Tester
Get Price Quote
1 Piece (MOQ)
10KV ACDC High Voltage Tester
Get Price Quote
0 to 10KV DC & 0 to 10KV AC 3 Digit LED display for KV & mA Timer 0 to 5 minutes variable Leakage current selectable 100 m A HT buzzer indication Selection of DC / AC output Suitable HT Probe
high voltage testers
Get Price Quote
1 Piece (MOQ)
high voltage testers
H.V. Tester
25,500 Per Piece
1 Unit (MOQ)
high voltage tester is use for high voltage test.
AC High Voltage Test Sets - Breakdown Type
Get Price Quote
AC high Voltage breakdown testers are designed for testing LT equipment and Home appliances as per ISIEC standards. Even the smallest units are complete with all required accessories and features that are provided on the most advance high capacity unit. The unit is designed keeping safety as an utmost priority. It is suitable for application in Laboratories, made units and sites.
75KV High Voltage Tester
85,000 Per Piece
ac high voltage breakdown tester
Get Price Quote
510 KV, capacity 10KVA, Input Current 50 Amps.Complete with 2 Analog meters & tripping cureent facility at 10A,20A,30 A & 50 Amps.,Heavy duty air cooled transformer is used.
High Voltage Breakdown Tester
Get Price Quote
To keep up with the set international standards, we have incorporated the latest machines and cutting-edge technology to sternly examine the material used for production. We have installed all the requisite amenities, necessary for making safe side deliveries. High Voltage Breakdown Tester AC Set: (Classic Model) Input : 230V AC, 50Hz. Output : 0-100 kV AC @ 100mA, One side grounded- 50% duty cycle. Oil Cooled Type, Transformer enclosed in MS Enclosure duly powder coated with wheels at bottom. High voltage lead taken out through high voltage bushing at top. Control Panel for above : A powder coated control panel with necessary meters to read different parameters such as input voltage, output voltage, leakage current, current limiting resistor.