Temperature Indicators
We are a major Temperature Indicators Manufacturer, Exporter and Supplier in Ernakulam, Kerala. Our Temperature Indicators have special design which enables accurate functioning in indication temperatures accurately. Our Temperature Indicators are made out of superior quality components which ensure high performance. The Temperature Indicators that we offer are in accordance to the international quality standards and are economic too. Specifications : RTD /Thermocouple or 4 テ「20 mA2 wire transmitters0.3" ,0.5",1" & 4" displays230v ac,110vdc & 24Vdc
...moreTemperature Data Logger
Our DL04/DL08/DL-16 Temperature Data Loggers are our 4/8/16-channel, RTD based temperature recorders. This Temperature Data Logger is an all-in-one compact, portable, easy-to-use device that will measure and record up to 10,922 measurements per channel. Our Temperature Data Logger can be operated directly by 220V AC or (either by two parallel 9V Lithium batteries for 36 hours continuously itテ「冱 optional). The strong medium is non-volatile solid-state memory, providing maximum data security even if the battery becomes discharged. The Temperature Data Logger can be started and stopped directly from your computer and its small size allows it to fit almost anywhere. We are offering additional Digital Display in front of the cold stores, processing halls etc so you can keep our master units near to your computer. The Data Logger makes data retrieval quick and easy. Simply plug it into an available COM port and the easy-to-use windows software does the rest. The Windows software converts the PC into a real time strip chart recorder. Data can be printed in graphical or tabular format and can also be exported to a text or Microsoft excel file. Advantages Of Temperature Data Logger : 100pt RTD inputReal time operationProgrammable start timeU set calibration through software0.1 degree resolution
...moreProcess Indicator
Level Transmitters
We present highly reliable Level Transmitters to our reputed clients. A study of transmission line theory is required to prove this phenomenon. An equivalent circuit for the coated section is shown as a ladder network producing the phase shifted error signal. One way to cancel the error signal is to measure the conductive component (c) shown in Figure 3 Method A. Since the 45o relationship exists, the capacitive error component (e) is the same magnitude and can be subtracted from the total output signal, thus effectively canceling the error signal. Another cancellation method use is to introduce a 45テつコ phase shift to the entire measurement as shown in Figure 3, Method B. This automatically cancels the coating error portion because the conductance component (c) still has the same magnitude as the error component (e), resulting in the appropriate level signal. For Continues Level & Volume Measurement Of All Liquids, Slurries & Powders : Electronic cancellation of conductive coating on probesSpecially designed to use with strong acids & alkalis Fully insulated probe for conductive liquids No maintenance & probe cleaning v250 khz. Operation Factory calibrated transmitter4 テ「20 ma , 3wire10 テ「 32 v dc power supplyProgrammable display & control unit with bar graphUp to 4 change over contact output (h, l, hh &ll)Volume, level & percentage display Suitable For : All acidsAlkalis & chemical solvents milkBeveragesPowders latex & paintsWater, diesel & edible & non edible oils effluents Basic Measurement Principle : A capacitor is formed when a level-sensing electrode is installed in a vessel. The metal rod of the electrode acts as one plate of the capacitor and the tank wall (or reference electrode in a non-metallic vessel) acts as the other plate. As the level of the material being measured rises, the air or gas normally surrounding the electrode is displaced by the material's different dielectric constant. The value of the capacitor changes because the dielectric between the two plates has changed. RF capacitance instruments detect this change and convert it into a relay actuation or proportional output signal. The following equation illustrates the capacitance relationship: C = 0.225 K (A+D) Where : C = Capacitance in pico farads K = Dielectric Constant of material A = Area of plates in square inches D = Distance between the plates in inches The dielectric constant is a numerical value between 1 and 100 that relates to the ability of the dielectric (material measured between the plates) to store an electrostatic charge. The dielectric constant of a material is determined in an actual test cell. In actual practice, capacitance change is produced in different ways depending on the material being measured and the level electrode being used. However, the basic principle always applies. If a higher dielectric material replaces a lower one, the total capacitance output of the system will increase. If the electrode is made larger (effectively increasing the surface area) the capacitance output increases; if the distance between measuring electrode and reference decreases, then the capacitance output increases. Non-Conductive Materials : The capacitance changes as material comes between the plates of the capacitor. For example, suppose the sensor and the metal walls are measuring the increasing level of a non-conductive material such as oil. Figure 1 depicts a typical system. While the actual capacitive equation is very complex, it can be approximated for the above example as follows : C = 0.225 (K air x A air) + 0.225 (K material x A material)Dair Dmaterial Since the electrode and tank wall are fixed in place, the distance between them will not vary. Similarly, the dielectric of air (1) and the measured material, oil (3.1), also remain constant. Therefore, the capacitance output of the system example can be reduced to this very basic equation: C = (1 x A air) + (3.1 x A material) As this equation demonstrates, the more material in the tank, the higher the capacitance output will be. The capacitance is directly proportional to the level of the measured material. Conductive Materials : The same logic for nonconductive materials applies to conductive materials, except that conductive material acts as the ground plate of the capacitor rather than the tank wall. This changes the distance aspect of the equation, whereby the output would be comparatively higher than for a nonconductive material. However, it still remains fixed; therefore, as level rises on the vertically mounted sensor, the output increases proportionately. A material is considered conductive when it has a conductivity value of greater than 10 micro Siemens /cm. The level-sensing electrode must be insulated. A non insulated sensor is tip sensitive and acts like a conductive switch. Material Buildup : The most devastating effect on the accuracy of RF capacitive measurements is caused by the buildup of conductive material on the electrode surface. Non-conductive buildup is not as serious since it only represents a small part of the total capacitance. The Level Probe : The probe used in this device is a stainless steel rod, fully insulated with HDPE/PTFE which does not make any direct contact with the medium. The capacitance formed by the probe rod and the conductive material is proportional to the level of material in the tank (ie), as the level increases the capacitance also increases. The Transmitter : A crystal controlled radio frequency sine wave of fixed peak voltage is passed through the capacitance formed by the tank body and the probe in series with a known capacitance. The voltage drop across the fixed capacitor will be 90テつコ out of phase with the applied wave form and is proportional to the tank capacitance. Compensating For Conductive Material Buildup : Coating error is illustrated by the diagram shown in Figure 2. The submerged portion of the electrode generates nearly a pure capacitive susceptance. Since the electrode is insulated, a conductive component is virtually non-existent. However, the upper section of the electrode, coated with conductive material, generates an error signal consisting of a capacitive susceptance and a conductive component. The result is an admittance component that is 45テつコ out of phase with the main level signal. Specifications Transmitter & Probe Principle of OperationRF Capacitance/AdmittanceProbe Fully Insulated (HDPE/PTFE)SS rod/Coaxial ProbeProbe LengthAs per the tank heightEnclosure NylonCompensation for moistureProvidedEnclosure ProtectionWeather proof- IP65Wetted PartsSS 316/ HDPE/PTFEProcess ConnectionFlanged /screwedFlange StandardANSIFlange Size & Rating1 テつス" 150 lb.Mounting Silo TopElectrical Connectionテつセ" E.TPower Supply 10 to32 V,DC(or from display unit)Cable Type & Size3core x 0.75 sq.mm screened PVC cableOutput 4 - 20 mADimensions 65 mm () x 100mm (H) Control & Display Unit (Micro Controller Based) Power Supply220V, AC,50 Hz./ 24V,DCPower Consumption< 10 Watts.Sensitivity AdjustmentProvidedEnclosure WeatherproofMounting Wall mounted / Panel MountedAlarms Upper & Lower limit,230V,5A change over contactsDisplay 5 Digit LED Display /4Digit LED +20segment BargraphCalibration Field Calibration FacilityAccuracy 0.01% of FSResolution 1/65000Dimensions 92mm x92mm x110mm /48mm x 92mm x110mm
...moreDigital Display
We are a reputed Digital Display Manufacturer, Exporter and Supplier in Ernakulam, Kerala. This Digital Display Process Indicator is designed to display almost all parameter used in industry like temperature, pressure, level, flow, humidity, pH, etc. It accepted all standers inputs such as thermocouple, RTD, mv, ma. Our Digital Display is very easy to operate and is highly functional. These Digital Display have long service life due to the use of bets quality components in the production process. Why Our Digital Display? Distant visibilityLonger lastingSmooth functioningNo maintenance Used For The Indication of : Clock indicationTemperatureParameter indicationHumidity
...moreDesktop pH Meter
We are instrumental in offering Desktop pH Meter, which is appreciated for its accuracy. This Desktop pH Meter is highly reliable in the pH determination. Our Desktop pH Meter is equipped with latest technology which ensures accuracy in functioning and easy operations. The Desktop pH Meters that we offer has a compact design with a large display. Features : Automatic temperature compensation3 Digit temperature displayCombined pH electrode Used To Determine The pH Level Of The Liquid In : Chemical industryAll liquid based industries
...moreCircular Chart Recorder
We have come up with the exclusive Circular Chart Recorder. This Circular Chart Recorder is very efficient and provides readings with complete accuracy. These Circular Chart Recorders are in compliance with the approved standards and are easy to use. These Circular Chart Recorders have a flawless circuit which is allows it to take the readings in a perfect way. These Circular Chart Recorders can be obtained at market leading prices. Specifications : Input : RTD, Thermocouple4-20mA, 0 テ「5VMicrocontroller based circuit
...moreCalibration Bench
We present cutting-edge Calibration Bench to our reputed clients. These Calibration Benches are fabricated with the use of high quality component to ensure perfect functioning. Our Calibration Benches are known for their smart control panel which makes it easy to operate it. These Calibration Benches are in conformation to the international standards and have accurate functioning. Features Of Calibration Bench : mA/mV/テ誌 Source& measureMercury &Water Manometers250 mm Dial Test Gauge230ac 24V D.C Power Supplies Used For : Primary Level / Precision Calibration & Testing of Pneumatic instrumentsElectro-Pneumatic & Hydraulic Pressure instruments
...morepH Controller
We bring forth highly efficient range of pH Controllers. This pH Controller is a user-friendly device which can accurately control the load signals. Used in Electrical and various other industries, these pH Controllers are user-friendly devices. Our pH Controller has electrode self cleaning system and is highly functional. These pH Controllers come with a weather-proof enclosure to offer safe usage. Why Our pH Controller? 4 テ「20 mA output for 0 テ「14 pHWeather proof enclosureElectrode self cleaning system2 set Relay output solenoidValve operationpH /Millivolt &TemperatureDisplay : Front panel calibration
...morepH Transmitters
Leveraging upon our expertise in this field, we manufacture pH Transmitters. Compactly designed, our pH Transmitters are highly efficient in the transmission of load signals. These pH Transmitters are manufactured with the use of sophisticated components that make them very functional. Our pH Transmitters can be obtained at market leading prices. Why Our pH Transmitters? 4 テ「20 mA output for 0 テ「14 pHWeather proof enclosureElectrode self cleaning system2 set Relay output solenoidValve operationpH /Millivolt &TemperatureDisplay : Front panel calibration
...moreOnline pH Controller
process control equipments
ph online controller
process control equipment
digital jumbo indicators
industrial process control eqiupment
Jumbo Process Indicator
Active Power Factor Correction Front End Module-single & 3phase
Igbt based buck power factor correction dc supply for single &3phase ups. 2 to 100kva ,dc voltages 48 to 400. Powerfactor >0.99 ,from 10% load to 100% loads
...moreBe first to Rate
Rate ThisOpening Hours